Literature DB >> 30524180

Examining the use of USEPA's Generic Attenuation Factor in determining groundwater screening levels for vapor intrusion.

Yijun Yao1,2,3, Iason Verginelli4, Eric M Suuberg5, Bart Eklund6.   

Abstract

A value of 0.001 is recommended by the United States Environmental Protection Agency (USEPA) for its groundwater-to-indoor air Generic Attenuation Factor (GAFG), used in assessing potential vapor intrusion (VI) impacts to indoor air, given measured groundwater concentrations of volatile chemicals of concern (e.g., chlorinated solvents). The GAFG can, in turn, be used for developing groundwater screening levels for VI given target indoor air quality screening levels. In this study, we examine the validity and applicability of the GAFG both for predicting indoor air impacts and for determining groundwater screening levels. This is done using both analysis of published data and screening model calculations. Among the 774 total paired groundwater-indoor air measurements in the USEPA's VI database (which were used by that agency to generate the GAFG) we found that there are 427 pairs for which a single groundwater measurement or interpolated value was applied to multiple buildings. In one case, up to 73 buildings were associated with a single interpolated groundwater value and in another case up to 15 buildings were associated with a single groundwater measurement (i.e, that the indoor air contaminant concentrations in all of the associated buildings were influenced by the concentration determined at a single point). In more than 70% of the cases (390 of 536 paired measurements in which horizontal building-monitoring well distance was recorded) the monitoring wells were located more than 30 meters (and some up to over 200 meters) from the associated buildings. In a few cases, the measurements in the database even improbably implied that soil gas contaminant concentrations increased, rather than decreased, in an upward direction from a contaminant source to a foundation slab. Such observations indicate problematic source characterization within the dataset used to generate the GAFG, and some indicate the possibility of a significant influence of a preferential contaminant pathway. While the inherent value of the USEPA database itself is not being questioned here, the above facts raise the very real possibility that the recommended groundwater attenuation factors are being influenced by variables or conditions that have not thus far been fully accounted for. In addition, the predicted groundwater attenuation factors often fall far beyond the upper limits of predictions from mathematical models of VI, ranging from screening models to detailed computational fluid dynamic models. All these models are based on the same fundamental conceptual site model, involving a vadose zone vapor transport pathway starting at an underlying uniform groundwater source and leading to the foundation of a building of concern. According to the analysis presented here, we believe that for scenarios for which such a "traditional" VI pathway is appropriate, 10-4 is a more appropriately conservative generic groundwater to indoor air attenuation factor than is the EPA-recommended 10-3. This is based both on the statistical analysis of USEPA's VI database, as well as the traditional mathematical models of VI. This result has been validated by comparison with results from some well documented field studies.

Entities:  

Year:  2018        PMID: 30524180      PMCID: PMC6277045          DOI: 10.1111/gwmr.12276

Source DB:  PubMed          Journal:  Ground Water Monit Remediat        ISSN: 1069-3629            Impact factor:   2.019


  10 in total

1.  Evaluation of vapor intrusion using controlled building pressure.

Authors:  Thomas E McHugh; Lila Beckley; Danielle Bailey; Kyle Gorder; Erik Dettenmaier; Ignacio Rivera-Duarte; Samuel Brock; Ian C MacGregor
Journal:  Environ Sci Technol       Date:  2012-04-17       Impact factor: 9.028

2.  Semianalytical model predicting transfer of volatile pollutants from groundwater to the soil surface.

Authors:  Olivier Atteia; Patrick Höhener
Journal:  Environ Sci Technol       Date:  2010-08-15       Impact factor: 9.028

3.  Identification of Alternative Vapor Intrusion Pathways Using Controlled Pressure Testing, Soil Gas Monitoring, and Screening Model Calculations.

Authors:  Yuanming Guo; Chase Holton; Hong Luo; Paul Dahlen; Kyle Gorder; Erik Dettenmaier; Paul C Johnson
Journal:  Environ Sci Technol       Date:  2015-11-05       Impact factor: 9.028

4.  Temporal variability of indoor air concentrations under natural conditions in a house overlying a dilute chlorinated solvent groundwater plume.

Authors:  Chase Holton; Hong Luo; Paul Dahlen; Kyle Gorder; Erik Dettenmaier; Paul C Johnson
Journal:  Environ Sci Technol       Date:  2013-11-14       Impact factor: 9.028

5.  Influence of Soil Moisture on Soil Gas Vapor Concentration for Vapor Intrusion.

Authors:  Rui Shen; Kelly G Pennell; Eric M Suuberg
Journal:  Environ Eng Sci       Date:  2013-10       Impact factor: 1.907

6.  A two-dimensional analytical model of vapor intrusion involving vertical heterogeneity.

Authors:  Yijun Yao; Iason Verginelli; Eric M Suuberg
Journal:  Water Resour Res       Date:  2017-05-22       Impact factor: 5.240

7.  Evidence of a sewer vapor transport pathway at the USEPA vapor intrusion research duplex.

Authors:  Thomas McHugh; Lila Beckley; Terry Sullivan; Chris Lutes; Robert Truesdale; Rob Uppencamp; Brian Cosky; John Zimmerman; Brian Schumacher
Journal:  Sci Total Environ       Date:  2017-04-26       Impact factor: 7.963

8.  Investigating the Role of Soil Texture in Vapor Intrusion from Groundwater Sources.

Authors:  Yijun Yao; Yue Wang; Zhong Zhong; Mengling Tang; Eric M Suuberg
Journal:  J Environ Qual       Date:  2017-07       Impact factor: 2.751

9.  Sewer Gas: An Indoor Air Source of PCE to Consider During Vapor Intrusion Investigations.

Authors:  Kelly G Pennell; Madeleine Kangsen Scammell; Michael D McClean; Jennifer Ames; Brittany Weldon; Leigh Friguglietti; Eric M Suuberg; Rui Shen; Paul A Indeglia; Wendy J Heiger-Bernays
Journal:  Ground Water Monit Remediat       Date:  2013       Impact factor: 2.019

10.  Estimation of Contaminant Subslab Concentration in Vapor Intrusion Including Lateral Source-Building Separation.

Authors:  Yijun Yao; Rui Shen; Kelly G Pennell; Eric M Suuberg
Journal:  Vadose Zone J       Date:  2013-08       Impact factor: 3.289

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.