Experimental validation of estimated spatially variant radioisotope-specific point spread functions using published positron range simulations and fluorine-18 measurements.

Jose M Anton-Rodriguez1, Georgios Krokos, Fotis Kotasidis, Marie-Claude Asselin, Olivia Morris, Peter Julyan, Anthony Archer, Julian C Matthews.   

Abstract

In this work we compare spatially variant radioisotope-specific point spread functions (PSFs) derived from published positron range data with measured data using a high resolution research tomograph (HRRT). Spatially variant PSFs were measured on a HRRT for fluorine-18, carbon-11 and gallium-68 using an array of printed point sources. For gallium-68, this required modification of the original design to handle its longer positron range. Using the fluorine-18 measurements and previously published data from Monte-Carlo simulations of positron range, estimated PSFs for carbon-11 and gallium-68 were calculated and compared with experimental data. A double 3D Gaussian function was fitted to the estimated and measured data and used to model the spatially varying PSFs over the scanner field of view (FOV). Differences between the measured and estimated PSFs were quantified using the full-width-at-half-maximum (FWHM) and full-width-at-tenth-maximum (FWTM) in the tangential, radial and axial directions. While estimated PSFs were generally in agreement with the measured PSFs over the entire FOV better agreement was observed (FWHM and FWTM differences of less than 10%) when using one of the two sets of positron range simulations, especially for gallium-68 and for the FWTM. Spatially variant radioisotope specific PSFs can be accurately estimated from fluorine-18 measurements and published positron range data. We have experimentally validated this approach for carbon-11 and gallium-68, and such an approach may be applicable to other radioisotopes such as oxygen-15 for which measurements are not practical.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30524089     DOI: 10.1088/1361-6560/aaecb6

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  1 in total

1.  Positron range in combination with point-spread-function correction: an evaluation of different implementations for [124I]-PET imaging.

Authors:  Hunor Kertész; Maurizio Conti; Vladimir Panin; Jorge Cabello; Deepak Bharkhada; Thomas Beyer; Laszlo Papp; Walter Jentzen; Jacobo Cal-Gonzalez; Joaquín L Herraiz; Alejandro López-Montes; Ivo Rausch
Journal:  EJNMMI Phys       Date:  2022-08-19
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.