Literature DB >> 30523945

Noninvasive vascular occlusion with HIFU for venous insufficiency treatment: preclinical feasibility experience in rabbits.

N Barnat1, A Grisey, B Lecuelle, J Anquez, B Gerold, S Yon, J-F Aubry.   

Abstract

Venous insufficiency is a common disease arising when veins of the lower limb become incompetent. A conventional surgical strategy consists in stripping the incompetent veins. However, this treatment option is invasive and carries complication risks. In the present study, we propose noninvasive high-intensity focused ultrasound (HIFU) to treat lower limbs venous insufficiency, in particular incompetent perforating veins (mean diameter between 2-6 mm). Sonication parameters were designed by numerical simulations using the k-Wave toolbox to ensure continuous coagulation of a vein with a diameter superior or equal to 2 mm. The selected ultrasound exposures were 4 s pulses in continuous wave mode. Two types of sonication were studied: (1) fixed pulses and (2) moving pulses at constant speed (0.75 mm s-1) across the vein. The potential of these exposures to thermally occlude veins were investigated in vivo on rabbit saphenous veins. The impact of vein compression during ultrasonic exposure was also investigated. Fifteen rabbits were used in these trials. A total of 27 saphenous veins (mean diameter 2.0  ±  0.6 mm) were sonicated with a transducer operated at 3 MHz. After a mean 15 d follow-up, rabbits were euthanized and venous samples were extracted and sent for histologic assessment. Only samples with the vein within the HIFU lesion were considered for analysis. Simulated thermal damage distribution demonstrated that fixed pulses and moving pulses respectively placed every 1.5 and 0.5 mm along the vein and delivered at an acoustic power of 85 W and for 4 s were able to induce continuous thermal damages along the vein segments. Experimentally, both treatment parameters (1) and (2) have proven effective to occlude veins with a success rate of 82%. Occlusion was always observed when compression was applied. Our results demonstrate that HIFU can durably and non-invasively occlude veins of diameters comparable to human veins.

Entities:  

Mesh:

Year:  2019        PMID: 30523945     DOI: 10.1088/1361-6560/aaf58d

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Hemodynamic analysis of intermittent pneumatic compression combined with hyperthermia after total hip arthroplasty: an experiment on male rabbits.

Authors:  Siping Zhang; Pengcheng Ma; Aikeremujiang Muheremu; Rongxin Sun; Hao Chai; Kan Jiang
Journal:  Am J Transl Res       Date:  2022-05-15       Impact factor: 3.940

2.  Extracorporeal Treatment with High Intensity Focused Ultrasound of an Incompetent Perforating Vein in a Patient with Active Venous Ulcers.

Authors:  Alfred Obermayer; Jean-François Aubry; Nesrine Barnat
Journal:  EJVES Vasc Forum       Date:  2020-12-05

3.  The interaction of shockwaves with a vapour bubble in boiling histotripsy: The shock scattering effect.

Authors:  Ki Joo Pahk; Sunho Lee; Pierre Gélat; Matheus Oliveira de Andrade; Nader Saffari
Journal:  Ultrason Sonochem       Date:  2020-08-18       Impact factor: 7.491

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.