Abstract

BACKGROUND: We performed a randomised blinded pilot study in 16 healthy volunteers to assess whether placing a suture-method catheter in the adductor canal is feasible with two different insertion techniques.
METHODS: Each volunteer had a suture-method catheter placed approximately halfway between the superior anterior iliac spine and base of the patella in both legs. Catheters were placed using a parallel technique in one leg and a perpendicular technique in the other leg, according to randomisation. 15 mL lidocaine 1% was injected in each catheter. Successful placement was defined as loss of cold sensation in the saphenous area 30 min after injection. Volunteers were sent home and returned the following day and another dose of lidocaine (15 mL, 1%) was injected through the catheters. Catheter displacement distance was assessed by ultrasound and cold sensation was assessed. In case of preserved cold sensation, we attempted to reposition the catheter with a subsequent injection of lidocaine and reassessment of cold sensation.
RESULTS: All primary placements were successful using the perpendicular approach (100%; 95% CI 81%-100%) whereas one placement failed using the parallel approach (94%; 95% CI 72%-99%). Three catheters placed using the perpendicular approach were displaced on day 2, compared to one catheter placed with the parallel approach. Displacement distance was highly variable. All catheters, except one, could be repositioned. Three volunteers reported transient sensory deficits lasting approximately 6-8 weeks.
CONCLUSION: The suture-method catheter can be placed in the adductor canal with high success rates for initial placement with both techniques.
© 2018 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30520017     DOI: 10.1111/aas.13300

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  1 in total

1.  Incidence of Suture-Method Catheter Dislocation with Femoral Nerve Block and Femoral Triangle Block after Total Knee Arthroplasty.

Authors:  Bulat Tuyakov; Mateusz Kruszewski; Lidia Glinka; Oksana Klonowska; Michal Borys; Pawel Piwowarczyk; Dariusz Onichimowski
Journal:  Int J Environ Res Public Health       Date:  2021-06-22       Impact factor: 3.390

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.