Literature DB >> 30517066

Is Optical Coherence Tomography a Potential Tool to Evaluate Marginal Adaptation of Class III/IV Composite Restorations In Vivo?

H Schneider, A S Steigerwald-Otremba, M Häfer, F Krause, M Scholz, R Haak.   

Abstract

OBJECTIVE: Margin analysis of Class III and IV composite restorations in vitro and in vivo occurred by scanning electron microscopy (SEM) and optical coherence tomography (OCT). The results were compared and related to clinical evaluation. METHODS AND MATERIALS: Eight Class III composite restorations were imaged in vitro using OCT and SEM. The margins were analyzed quantitatively. OCT signals were verified by assignment to the criteria perfect margin, gap, and positive/negative ledge. In vivo quantitative margin analysis of Class III/IV composite restorations made of the micro-hybrid composite Venus combined with the self-etch adhesive iBond Gluma inside (1-SE) or etch-and-rinse adhesive Gluma Comfort Bond (2-ER) (all Heraeus Kulzer) was carried out using OCT and SEM after 90 months of clinical function. The results were compared with clinical evaluation (US Public Health Service criteria; marginal integrity, marginal discoloration).
RESULTS: In vitro, the correlation between OCT and SEM was high for all four margin criteria (Kendall tau b [τb] correlation: 0.64-0.92, pi≤0.026), with no significant differences between OCT and SEM (pi≥0.63). In vivo, a moderate correlation was observed (τb: 0.38-0.45, pi<0.016). Clinically, the cumulative failure rate in the criterion marginal integrity was higher for the 1-SE group (baseline 90 M, p=0.011). Similarly, OCT and SEM detected higher percentages of the criterion gap in the 1-SE group (p: 0.027/0.002), in contrast to perfect margin. Both, gap and perfect margin ranged widely between 0.0% and 88.7% (OCT) and between 0.0% and 89.0% (SEM).
CONCLUSION: Despite the positive selection bias after 90 months with only a few patients left, quantitative margin analysis allows for differentiation between the two adhesives at this specific date. OCT in particular offers the possibility to evaluate marginal integrity directly in vivo.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30517066     DOI: 10.2341/17-192-C

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  3 in total

1.  Handheld optical coherence tomography for clinical assessment of dental plaque and gingiva.

Authors:  Jungeun Won; Pin-Chieh Huang; Darold R Spillman; Eric J Chaney; Ralf Adam; Malgorzata Klukowska; Ronit Barkalifa; Stephen A Boppart
Journal:  J Biomed Opt       Date:  2020-11       Impact factor: 3.170

2.  OCT evaluation of orthodontic surface sealants: a 12-month follow-up randomized clinical trial.

Authors:  Sinan Şen; Ralf Erber; Gül Orhan; Sebastian Zingler; Christopher J Lux
Journal:  Clin Oral Investig       Date:  2020-08-13       Impact factor: 3.573

3.  Evaluation of low-viscosity bulk-fill composites regarding marginal and internal adaptation.

Authors:  Kyung-Jin Park; Manon Pfeffer; Thomas Näke; Hartmut Schneider; Dirk Ziebolz; Rainer Haak
Journal:  Odontology       Date:  2020-06-09       Impact factor: 2.634

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.