Literature DB >> 30516414

A randomized clinical trial to evaluate the plaque removal efficacy of an oscillating-rotating toothbrush versus a sonic toothbrush in orthodontic patients using digital imaging analysis of the anterior dentition.

Christina Erbe, Collin Jacobs, Malgorzata Klukowska, Hans Timm, Julie Grender, Heinrich Wehrbein.   

Abstract

OBJECTIVE: To compare the plaque removal efficacy of an oscillating-rotating electric toothbrush with an orthodontic brush head versus a sonic toothbrush in adolescent patients with fixed orthodontic appliances.
MATERIALS AND METHODS: This was a randomized, examiner-blind, replicate single-use, two-treatment, four-period, crossover study with a washout period between visits of approximately 24 hours. Forty-four adolescent patients with fixed orthodontic appliances in both arches were randomized based on a computer-generated randomization schedule to one of four toothbrush treatment sequences. The primary outcome was plaque score change from baseline, measured using digital plaque imaging analysis.
RESULTS: Baseline plaque levels for both brush treatments were high, covering more than 50% of the tooth area. Effective plaque removal was observed with both brush treatments (P < .001); however, the reduction in plaque with the oscillating-rotating toothbrush was statistically significantly greater (P = .017) compared with the sonic toothbrush.
CONCLUSIONS: The study provides evidence for more effective plaque-removing efficacy of the oscillating-rotating toothbrush versus the sonic toothbrush among orthodontic patients.

Entities:  

Keywords:  Oral hygiene; Orthodontic; Plaque removal; Power toothbrushes

Mesh:

Year:  2018        PMID: 30516414      PMCID: PMC8117681          DOI: 10.2319/080317-520.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  30 in total

1.  Objective quantification of plaque using digital image analysis.

Authors:  P A Sagel; P G Lapujade; J M Miller; R J Sunberg
Journal:  Monogr Oral Sci       Date:  2000

2.  An advanced toothbrush with improved plaque removal efficacy.

Authors:  N C Sharma; J G Qaqish; H J Galustians; D W King; M A Low; D M Jacobs; D A Weber
Journal:  Am J Dent       Date:  2000-03       Impact factor: 1.522

3.  Changes in the subgingival microbiota and periodontal parameters before and 3 months after bracket placement.

Authors:  Andrea Amezquita Naranjo; Martha Lucia Triviño; Adriana Jaramillo; Marisol Betancourth; Javier Enrique Botero
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-09       Impact factor: 2.650

4.  Comparative cleansing efficiency of manual and power brushing.

Authors:  G A QUIGLEY; J W HEIN
Journal:  J Am Dent Assoc       Date:  1962-07       Impact factor: 3.634

5.  Efficacy of 3 toothbrush treatments on plaque removal in orthodontic patients assessed with digital plaque imaging: a randomized controlled trial.

Authors:  Christina Erbe; Malgorzata Klukowska; Iris Tsaknaki; Hans Timm; Julie Grender; Heinrich Wehrbein
Journal:  Am J Orthod Dentofacial Orthop       Date:  2013-06       Impact factor: 2.650

Review 6.  Plaque removal efficacy of oscillating-rotating power toothbrushes: review of six comparative clinical trials.

Authors:  Julie Grender; Karen Williams; Pat Walters; Malgorzata Klukowska; Hansjoerg Reick
Journal:  Am J Dent       Date:  2013-04       Impact factor: 1.522

7.  Effect of orthodontic therapy with fixed and removable appliances on oral microbiota: a six-month longitudinal study.

Authors:  S Petti; E Barbato; A Simonetti D'Arca
Journal:  New Microbiol       Date:  1997-01       Impact factor: 2.479

8.  Plaque levels of patients with fixed orthodontic appliances measured by digital plaque image analysis.

Authors:  Malgorzata Klukowska; Annike Bader; Christina Erbe; Philip Bellamy; Donald J White; Mary Kay Anastasia; Heiner Wehrbein
Journal:  Am J Orthod Dentofacial Orthop       Date:  2011-05       Impact factor: 2.650

9.  One-third of orthodontic patients receiving fixed appliances in a US graduate clinic have new iatrogenic demineralized white lesions at the end of treatment.

Authors:  Philip Benson
Journal:  J Evid Based Dent Pract       Date:  2011-06       Impact factor: 5.267

10.  A 3-month comparative investigation of the safety and efficacy of a new toothbrush: results from two independent clinical studies.

Authors:  N C Sharma; J G Qaqish; H J Galustians; D W King; M A Low; D M Jacobs; D A Weber
Journal:  Am J Dent       Date:  2000-03       Impact factor: 1.522

View more
  5 in total

1.  Randomized controlled trial assessing plaque removal of an oscillating-rotating electric toothbrush with micro-vibrations.

Authors:  Ralf Adam; Jasmin Erb; Julie Grender
Journal:  Int Dent J       Date:  2020-04       Impact factor: 2.607

2.  Introducing the Oral-B iO electric toothbrush: next generation oscillating-rotating technology.

Authors:  Ralf Adam
Journal:  Int Dent J       Date:  2020-04       Impact factor: 2.607

Review 3.  Safety and Design Aspects of Powered Toothbrush-A Narrative Review.

Authors:  Clarence Ng; James Kit Hon Tsoi; Edward C M Lo; And Jukka P Matinlinna
Journal:  Dent J (Basel)       Date:  2020-02-05

Review 4.  Powered Toothbrushes: An Opportunity for Biofilm and Gingival Inflammation Control.

Authors:  Cassiano Kuchenbecker Rösing; Eduardo Garduño; Sandra Kalil Bussadori; Agustín Zerón; Paulo Vinícius Soares; Marc Saadia; Cristina Cunha Villar
Journal:  Int J Dent       Date:  2022-08-22

5.  An 8-week randomized controlled trial comparing the effect of a novel oscillating-rotating toothbrush versus a manual toothbrush on plaque and gingivitis.

Authors:  Julie Grender; C Ram Goyal; Jimmy Qaqish; Ralf Adam
Journal:  Int Dent J       Date:  2020-04       Impact factor: 2.607

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.