Literature DB >> 30516061

Clinical evaluation of the repeatability of ocular aberrometry obtained with a new pyramid wavefront sensor.

Ana B Plaza-Puche1, Liberdade C Salerno1, Francesco Versaci2, Daniel Romero3, Jorge L Alio1,3.   

Abstract

PURPOSE: To evaluate the intrasubject repeatability of the ocular aberrometry obtained with a new ocular pyramidal aberrometer technology in a sample of normal eyes.
METHODS: A total of 53 healthy eyes of 53 subjects with ages ranging from 18 to 45 years were included in this study. In all cases, three consecutive acquisitions were obtained. Intrasubject repeatability of the measurements with a pyramidal aberrometer was calculated. Intrasubject repeatability for 4.0- and 6.0-mm pupils was evaluated within the subject standard deviation (Sw) and intraclass correlation coefficient.
RESULTS: Low values of the Sw and intraclass correlation coefficient outcomes close to 1 were observed for the sphere and cylinder at 3.0-mm pupil size. Most low Sw and intraclass correlation coefficient values close to 1 were observed for total, low-order aberrations and higher-order aberrations root mean square and for each Zernike coefficient analysis (intraclass correlation coefficient ⩾0.798) at 4.0-mm pupil size, with more limited outcomes for the aberrometric coefficient of Z(4, 4) with an intraclass correlation coefficient of 0.683. For a 6.0 mm pupil diameter, low Sw and intraclass correlation coefficient values close to 1 were observed for all aberrometric parameters or Zernike coefficients analyzed (intraclass correlation coefficient ⩾0.850).
CONCLUSION: The new pyramidal aberrometer Osiris provides repeatable and consistent measurements of ocular aberrometry measurements in normal eyes.

Entities:  

Keywords:  Ocular aberrometry; intrasubject repeatability; pyramidal aberrometer

Mesh:

Year:  2018        PMID: 30516061     DOI: 10.1177/1120672118816060

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  4 in total

Review 1.  IMI 2021 Yearly Digest.

Authors:  Monica Jong; Jost B Jonas; James S Wolffsohn; David A Berntsen; Pauline Cho; Danielle Clarkson-Townsend; Daniel I Flitcroft; Kate L Gifford; Annechien E G Haarman; Machelle T Pardue; Kathryn Richdale; Padmaja Sankaridurg; Milly S Tedja; Christine F Wildsoet; Joan E Bailey-Wilson; Jeremy A Guggenheim; Christopher J Hammond; Jaakko Kaprio; Stuart MacGregor; David A Mackey; Anthony M Musolf; Caroline C W Klaver; Virginie J M Verhoeven; Veronique Vitart; Earl L Smith
Journal:  Invest Ophthalmol Vis Sci       Date:  2021-04-28       Impact factor: 4.799

2.  Repeatability and reproducibility of corneal higher-order aberrations measurements after small incision lenticule extraction using the Scheimpflug-Placido topographer.

Authors:  Rui Ning; Rongrong Gao; David P Piñero; Jun Zhang; Qingyi Gao; Yili Jin; Yiran Wang; Chenxiao Wang; Jinhai Huang
Journal:  Eye Vis (Lond)       Date:  2022-01-04

3.  The optics of the human eye at 8.6 µm resolution.

Authors:  Sergio Bonaque-González; Juan M Trujillo-Sevilla; Miriam Velasco-Ocaña; Óscar Casanova-González; Miguel Sicilia-Cabrera; Alex Roqué-Velasco; Sabato Ceruso; Ricardo Oliva-García; Javier Martín-Hernández; Oscar Gomez-Cardenes; José G Marichal-Hernández; Damien Gatinel; Jack T Holladay; José M Rodríguez-Ramos
Journal:  Sci Rep       Date:  2021-12-02       Impact factor: 4.379

4.  Comment on: Keratopigmentation; a comprehensive review.

Authors:  Sergio Bonaque-González; Juan M Trujillo-Sevilla
Journal:  Eye (Lond)       Date:  2020-02-24       Impact factor: 3.775

  4 in total