Literature DB >> 30514733

Evaluating the effectiveness and safety of the carotid Casper-RX stent for tandem lesions in acute ischemic stroke.

Bruno Bartolini1, Francesco Puccinelli1, Pascal J Mosimann2, Steven D Hajdu1, Louis Veunac3, Patrik Michel4, Guillaume Saliou1.   

Abstract

INTRODUCTION: A new generation of carotid artery stents that use a dual micromesh layer to reduce embolic events during carotid artery stenting has recently been introduced. We aimed to analyze the effectiveness and safety of the new Casper-RX stent in patients experiencing acute ischemic stroke with large vessel intracranial occlusion associated with a tandem lesion (another carotid occlusion or severe stenosis).
METHODS: We retrospectively analyzed all consecutive patients treated with carotid Casper-RX stents from our stroke registry. We analyzed clinical, angiographic, and neuroimaging data. Endpoints included acute intra-stent thrombus formation, stent occlusion prior to hospital discharge, 3 month modified Rankin Scale score (mRS), and symptomatic intracranial hemorrhage.
RESULTS: 21 patients were included: 10 patients had tandem carotid occlusions and 11 patients had severe carotid stenosis, 8 of whom had a hemodynamically significant stenosis. We observed acute in-stent thrombus formation in 11 patients. No stent occlusion occurred prior to hospital discharge. We report no stroke recurrence at 3 months but symptomatic intracranial hemorrhage in two patients. mRS score at 3 months was 0-2 (favorable) for 15 patients (71%), 3-5 for 3 patients, and 6 for 3 patients.
CONCLUSIONS: In the present series, we frequently observed clot formation during the procedure with Casper-RX stents, which required periprocedural intravenous infusion of anticoagulant and antiplatelet treatment. This motivated us, in the absence of a prospective randomized controlled study demonstrating the non-inferiority of micromesh dual layer stents compared with the single layer design, to discontinue using this stent type in acute stroke requiring carotid angioplasty. © Author(s) (or their employer(s)) 2019. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  cervical; stent; stroke

Mesh:

Year:  2018        PMID: 30514733     DOI: 10.1136/neurintsurg-2018-014425

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  4 in total

Review 1.  Tandem Carotid Lesions in Acute Ischemic Stroke: Mechanisms, Therapeutic Challenges, and Future Directions.

Authors:  A Y Poppe; G Jacquin; D Roy; C Stapf; L Derex
Journal:  AJNR Am J Neuroradiol       Date:  2020-06-04       Impact factor: 3.825

2.  Comparison of Restenosis Risk in Single-Layer versus Dual-Layer Carotid Stents: A Duplex Ultrasound Evaluation.

Authors:  Ján Sýkora; Kamil Zeleňák; Martin Vorčák; Martin Števík; Martina Sýkorová; Jozef Sivák; Marek Rovňák; Jana Zapletalová; Juraj Mužík; Igor Šinák; Egon Kurča; Lukas Meyer; Jens Fiehler
Journal:  Cardiovasc Intervent Radiol       Date:  2022-07-07       Impact factor: 2.797

3.  Emergency carotid artery revascularization using Casper-RX stent: A single-center experience.

Authors:  Yigit Ozpeynirci; Cristian Capatana; Johannes Rosskopf; Bernd L Schmitz; Gerhard F Hamann; Michael Braun
Journal:  Interv Neuroradiol       Date:  2020-02-11       Impact factor: 1.610

4.  Safety and Efficacy of Carotid Artery Stenting with the CGuard Double-layer Stent in Acute Ischemic Stroke.

Authors:  Tomas Klail; Christoph Kurmann; Johannes Kaesmacher; Adnan Mujanovic; Eike I Piechowiak; Tomas Dobrocky; Sara Pilgram-Pastor; Adrian Scutelnic; Mirjam R Heldner; Jan Gralla; Pasquale Mordasini
Journal:  Clin Neuroradiol       Date:  2022-09-07       Impact factor: 3.156

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.