Literature DB >> 30514632

Sensitivity and Robustness of Spatially Dependent Thrombin Generation and Fibrin Clot Propagation.

Anna D Kuprash1, Alexey M Shibeko1, Ramya Vijay2, Sukesh C Nair2, Alok Srivastava2, Fazoil I Ataullakhanov3, Mikhail A Panteleev4, Anna N Balandina1.   

Abstract

Blood coagulation is a delicately regulated space- and time-dependent process that leads to the formation of fibrin clots preventing blood loss upon vascular injury. The sensitivity of the coagulation network was previously investigated without accounting for transport processes. To investigate its sensitivity to coagulation factor deficiencies in a spatial reaction-diffusion system, we combined an in vitro experimental design with a computational systems biology model. Clot formation in platelet-free plasma supplemented with phospholipids was activated with identical amounts of tissue factor (TF) either homogeneously distributed (concentration 5 pM, homogeneous model) or immobilized on the surface (surface density 100 pmole/m2, spatially heterogeneous model). Fibrin clot growth and thrombin concentration dynamic in space were observed using video microscopy in plasma of healthy donors or patients with deficiencies in factors (F) II, FV, FVII, FVIII, FIX, FX, or FXI. In the spatially heterogeneous model, near-activator thrombin generation was decreased in FV-, FVII-, and FX-deficient plasma. In the homogeneous model, clotting was not registered in these samples. The simulation and experiment data showed that the coagulation threshold depended on the TF concentration. Our data indicate that the velocity of spatial clot propagation correlates linearly with the concentration of thrombin at the clot wave front but not with the overall thrombin wave amplitude. Spatial clot growth in normal plasma at early stages was neither reaction nor diffusion limited but became diffusion limited later. In contrast, clot growth was always diffusion limited in FV-, FVII-, and FX-deficient plasma and reaction limited in FVIII-, FIX-, and FXI-deficient plasma. We conclude that robustness of the spatially heterogeneous coagulation system was achieved because of the combination of 1) a local high TF surface density that overcomes activation thresholds, 2) diffusion control being shared between different active factors, and 3) an early saturated stimulus-response dependence of fibrin clot formation by thrombin.
Copyright © 2018 Biophysical Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30514632      PMCID: PMC6301986          DOI: 10.1016/j.bpj.2018.11.009

Source DB:  PubMed          Journal:  Biophys J        ISSN: 0006-3495            Impact factor:   4.033


  2 in total

1.  Damped White Noise Diffusion with Memory for Diffusing Microprobes in Ageing Fibrin Gels.

Authors:  Rev R L Aure; Christopher C Bernido; M Victoria Carpio-Bernido; Rommel G Bacabac
Journal:  Biophys J       Date:  2019-08-21       Impact factor: 4.033

2.  Modeling Thrombin Generation in Plasma under Diffusion and Flow.

Authors:  Christian J C Biscombe; Steven K Dower; Ineke L Muir; Dalton J E Harvie
Journal:  Biophys J       Date:  2020-05-19       Impact factor: 4.033

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.