Literature DB >> 30510319

Assessing the sharpness of hypodermic needles after repeated use.

Kadin Majcher1, Dustin Eichorn1, Cheryl Waldner1, James Johnston1, Chris Clark1, Murray Jelinski1.   

Abstract

Four gauges (14G, 16G, 18G, 20G) of single use hypodermic needles were evaluated for sharpness by measuring the force required to puncture rehydrated bovine leather. The needles began to dull after 1 use with maximum bluntness occurring within 4 to 5 uses.

Entities:  

Mesh:

Year:  2018        PMID: 30510319      PMCID: PMC6135268     

Source DB:  PubMed          Journal:  Can Vet J        ISSN: 0008-5286            Impact factor:   1.008


  6 in total

1.  Breakage and deformation characteristics of hypodermic devices under static and dynamic loading.

Authors:  S J Hoff; P Sundberg
Journal:  Am J Vet Res       Date:  1999-03       Impact factor: 1.156

2.  Bovine leukosis virus infection in a dairy herd in Saskatchewan.

Authors:  P Brightling; O M Radostits
Journal:  Can Vet J       Date:  1983-11       Impact factor: 1.008

3.  Injection-site lesion prevalence and potential risk factors in UK beef cattle.

Authors:  E Cresswell; J Remnant; A Butterworth; W Wapenaar
Journal:  Vet Rec       Date:  2016-10-26       Impact factor: 2.695

4.  A study of the effectiveness of a needle-free injection device compared with a needle and syringe used to vaccinate calves against bovine viral diarrhea and infectious bovine rhinotracheitis viruses.

Authors:  Michel R Rey; Michael Undi; Juan C Rodriguez-Lecompte; Tomy Joseph; Jason Morrison; Alexander Yitbarek; Karin Wittenberg; Robert Tremblay; Gary H Crow; Kim H Ominski
Journal:  Vet J       Date:  2013-09-04       Impact factor: 2.688

5.  Comparison of iatrogenic transmission of Anaplasma marginale in Holstein steers via needle and needle-free injection techniques.

Authors:  James B Reinbold; Johann F Coetzee; Larry C Hollis; Jason S Nickell; Casey M Riegel; Julia A Christopher; Roman R Ganta
Journal:  Am J Vet Res       Date:  2010-10       Impact factor: 1.156

6.  Surgical needle sharpness.

Authors:  J G Thacker; G T Rodeheaver; M A Towler; R F Edlich
Journal:  Am J Surg       Date:  1989-03       Impact factor: 2.565

  6 in total
  1 in total

1.  The Effect of Needle Reuse on Piglet Skin Puncture Force.

Authors:  Kathryn Owen; Nicola Blackie; Troy John Gibson
Journal:  Vet Sci       Date:  2022-02-18
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.