Literature DB >> 30509746

Comparison of 3-month visual outcomes of a spherical and a toric trifocal intraocular lens.

Francisco Poyales1, Nuria Garzon2.   

Abstract

PURPOSE: To evaluate visual outcomes and satisfaction after implantation of 2 trifocal intraocular lenses (IOLs): a spherical IOL and a toric IOL.
SETTING: IOA Madrid Innova Ocular, Madrid, Spain.
DESIGN: Prospective, controlled clinical trial.
METHODS: Patients (>50 years) were implanted bilaterally with either a trifocal spherical hydrophilic IOL (FineVision POD F) if corneal astigmatism was 1.0 diopter (D) or less, or with a trifocal toric hydrophilic IOL (FineVision POD FT) if astigmatism was more than 1.0 D. Outcomes analyzed 3 months after surgery included monocular and binocular visual acuities at distance, near, and intermediate, both uncorrected and corrected. Defocus curves, contrast sensitivity, and patient satisfaction were also assessed.
RESULTS: There was no statistically significant difference between groups in monocular uncorrected distance (UDVA) (P = .38), monocular corrected distance (CDVA) (P = .22), or distance-corrected intermediate (DCIVA) (P = .95) visual acuities; however, the distance-corrected near visual acuity (DCNVA) was slightly better in the spherical IOL group (P = .008). The UDVA was 20/25 or better in 89% of eyes in the spherical IOL group and 93% in the toric IOL group. The DCIVA was 20/32 or better in 92% of eyes in the spherical IOL group and 93% in the toric IOL group at 80 cm (Radner Vissum chart), and 20/32 or better in 100% of eyes in both groups at 63 cm (Colenbrander chart). The DCNVA (Radner chart) was 20/32 or better in 89% of eyes in the spherical IOL group and 90% of eyes in the toric IOL group. There was no difference between the groups in contrast sensitivity, defocus curves, cylinder, or satisfaction results.
CONCLUSION: Patients had significant improvement in visual acuity and gained functional uncorrected visual acuity across all distances in both groups. Satisfaction was high with both IOLs.
Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2018        PMID: 30509746     DOI: 10.1016/j.jcrs.2018.09.025

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  4 in total

1.  Multivariate Regression Analysis Identifying Predictors of Patient Satisfaction with Multifocal IOLs: +4.00/+4.00 vs +3.25/+3.25 vs +3.25/EDOF.

Authors:  Frank A Bucci
Journal:  Clin Ophthalmol       Date:  2020-09-28

2.  Comparison of Visual Performance and Patient Satisfaction Outcomes with Two Trifocal IOLs with Similar Optical Design but Different Materials.

Authors:  Francisco Poyales; Ricardo Pérez; Israel López-Brea; Ying Zhou; Laura Rico; Nuria Garzón
Journal:  Clin Ophthalmol       Date:  2020-10-13

3.  Analyzing Effect of Waterclefts on Visual Functions Via Optical Simulations.

Authors:  Yusuke Seki; Takushi Kawamorita; Naoki Yamamoto; Takashi Tanigawa; Norihiro Mita; Natsuko Hatsusaka; Eri Kubo; Hiroshi Sasaki
Journal:  Invest Ophthalmol Vis Sci       Date:  2022-02-01       Impact factor: 4.799

4.  In Vitro Chromatic Performance of Three Presbyopia-Correcting Intraocular Lenses with Different Optical Designs.

Authors:  Diego Montagud-Martínez; Vicente Ferrando; Anabel Martínez-Espert; Salvador Garcia-Delpech; Juan A Monsoriu; Walter D Furlan
Journal:  J Clin Med       Date:  2022-02-24       Impact factor: 4.241

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.