Investigation of effects of urethane foam mattress hardness on skin and soft tissue deformation in the prone position using magnetic resonance imaging.

Ayumi Kumagai1, Naoki Ohno2, Tosiaki Miyati2, Mayumi Okuwa2, Toshio Nakatani2, Hiromi Sanada3, Junko Sugama4.   

Abstract

AIM: In operating rooms, the occurrence of pressure ulcers caused by being in the prone position is the highest among that of pressure ulcers caused by being in other surgical positions. Thus, we investigated effects of hardness and shape of urethane foam mattresses for preventing pressure ulcers during surgery performed with patients in the prone position. We aimed to elucidate how mattresses of variable hardness and shapes affect compression and displacement of the skin and soft tissues with external force in the prone position.
MATERIAL AND METHODS: We assessed effects of two shapes [rectangular cube (RC) and trapezoid cube (TC)] and four degrees of hardness (50, 87.5, 175, and 262.5 N) in each shape. We performed magnetic resonance imaging (MRI) of the iliac crests with external force while participants reclined in the prone position on eight different mattresses.
RESULTS: Compression of the skin and soft tissue was significantly higher with 87.5-, 175-, and 262.5-N mattresses than that with 50-N mattresses. Skin and soft tissue displacement was higher with TC mattress than that with RC mattress, and the extent of skin surface and internal soft tissue displacement was different.
CONCLUSIONS: Compression of the skin and soft tissue depends on mattress hardness; however, a threshold value (175 N) for hardness exists, above which no further changes in the parameters were observed. Skin and soft tissue displacement does not depend on mattress hardness, but rather on its shape. Furthermore, mattress inclination increases skin surface displacement.
Copyright © 2018 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Magnetic resonance imaging; Pressure ulcer prevention; Prone position; Skin and soft tissue; Urethane foam mattress

Mesh:

Substances:

Year:  2018        PMID: 30502973     DOI: 10.1016/j.jtv.2018.10.007

Source DB:  PubMed          Journal:  J Tissue Viability        ISSN: 0965-206X            Impact factor:   2.932


  2 in total

1.  Critical biomechanical and clinical insights concerning tissue protection when positioning patients in the operating room: A scoping review.

Authors:  Amit Gefen; Sue Creehan; Joyce Black
Journal:  Int Wound J       Date:  2020-06-04       Impact factor: 3.315

2.  Effect of napping on a bean bag chair on sleep stage, muscle activity, and heart rate variability.

Authors:  Masaki Nishida; Atsushi Ichinose; Yusuke Murata; Kohei Shioda
Journal:  PeerJ       Date:  2022-05-09       Impact factor: 3.061

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.