Literature DB >> 30501947

Dissected Aorta Repair Through Stent Implantation trial: Canadian results.

Sabin J Bozso1, Jeevan Nagendran1, Roderick G G MacArthur1, Michael W A Chu2, Bob Kiaii2, Ismail El-Hamamsy3, Raymond Cartier3, Ali Shahriari4, Michael C Moon5.   

Abstract

OBJECTIVES: We describe the Canadian results of the Ascyrus Medical Dissection Stent (AMDS), a novel partially uncovered aortic arch hybrid graft implanted antegrade during hypothermic circulatory arrest to promote true lumen expansion and enhance aortic remodeling.
METHODS: From March 2017 to February 2018, 16 consecutive patients (66 ± 12 years; 38% female) presented with acute type A aortic dissections and underwent emergent surgical aortic repair with AMDS implantation. All patients presented with DeBakey I aortic dissection, with evidence of malperfusion in 50% (n = 8) of patients. All cases were performed under hypothermic circulatory arrest with an additional average duration for AMDS implantation time of 2.1 minutes.
RESULTS: All 16 device implantations were successful. Overall 30-day mortality was 6.3% (n = 1) and stroke occurred in 6.3% (n = 1) of cases. There was no incidence of device-related aortic injury or aortic arch branch vessel occlusion. During the follow-up period, 12 patients had completed at least 1 postoperative computed tomography scan. At initial follow-up computed tomography scan, complete or partial thrombosis, and remodeling of the aortic arch occurred in 91.7% of cases (n = 11/12) and in the proximal descending thoracic aorta, complete or partial thrombosis, and remodeling occurred in 91.7% (n = 11/12).
CONCLUSIONS: Preliminary results suggest that the AMDS is a safe, feasible and reproducible adjunct to current surgical approaches for acute DeBakey I aortic dissection repair. Further, the AMDS manages malperfusion and promotes early positive remodeling in the aortic arch and distal dissected segments, with favorable FL closure rates at follow-up. Ongoing follow-up will provide additional insight into the long-term effects of the AMDS.
Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  aortic dissection; endovascular

Mesh:

Year:  2018        PMID: 30501947     DOI: 10.1016/j.jtcvs.2018.09.120

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  3 in total

1.  Hybrid arch frozen elephant trunk repair for acute type A intramural hematoma.

Authors:  Fadi Hage; Ali Hage; Michael W A Chu
Journal:  Ann Cardiothorac Surg       Date:  2019-09

2.  Initial experience with the new type A arch dissection stent: restoration of supra-aortic vessel perfusion.

Authors:  Matteo Montagner; Markus Kofler; Roland Heck; Semih Buz; Christoph Starck; Stephan Kurz; Volkmar Falk; Jörg Kempfert
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-07-26

3.  Early Results of a Novel Hybrid Prosthesis for Treatment of Acute Aortic Dissection Type A With Distal Anastomosis Line Beyond Aortic Arch Zone Zero.

Authors:  Arash Mehdiani; Yukiharu Sugimura; Louise Wollgarten; Moritz Benjamin Immohr; Sebastian Bauer; Hubert Schelzig; Markus Udo Wagenhäuser; Gerald Antoch; Artur Lichtenberg; Payam Akhyari
Journal:  Front Cardiovasc Med       Date:  2022-07-14
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.