Literature DB >> 30501928

Determination of central corneal clearance in scleral lenses with an optical biometer and agreement with subjective evaluation.

Rute J Macedo-de-Araújo1, Ana Amorim-de-Sousa2, António Queirós2, Eef van der Worp3, José M González-Méijome2.   

Abstract

PURPOSE: To compare three methods to measure central corneal clearance (CCC) during scleral lens wear: subjective (slit lamp), image processed (ImageJ) and with an optic biometer. The optic biometer technique was validated in comparison to an OCT in the first part of the study.
METHODS: Twenty-two eyes (11 subjects) with healthy corneas were recruited. Three measures of OCT with scleral lens and ten measurements of axial length (AL) with IOLMaster with and without lens were performed. For the second part, 61 eyes (35 subjects) enrolled in a clinical study were selected. Measurements of CCC were done with IOLMaster, SlitLamp and ImageJ.
RESULTS: The measurements of CCC indirectly obtained with IOLMaster had a strong correlation with AS-OCT measurements (r = 0.981), showing a mean difference of 122.18 ± 46.05 μm (higher with IOLMaster). Regarding the second part, measurements of CCC were 238.66 ± 95.94 μm, 250.16 ± 124.31 μm and 263.15 ± 90.60 μm, for the IOLMaster, SlitLamp and ImageJ, respectively. The correlations were higher for ImageJ vs Subjective measure (r = 0.891) than for IOL vs Subjective (r = 0.748) and IOL vs ImageJ (r = 0.745). Analysis of differences and correlations between SlitLamp and ImageJ through time showed a mean difference of -32.28 ± 89.95 μm (r = 0.683) at V1month, 12.53 ± 59.46 μm (r = 0.850) at V6months and 11.57 ± 32.95 μm (r = 0.940) at V12months.
CONCLUSIONS: It is possible to measure CCC with IOLMaster, considering AL measured with and without lens and lens thickness. The three methods tested have good correspondence, showing that IOLMaster and ImageJ could be objective techniques to measure CCC. Also, it is possible to improve the agreement of subjective measures when compared to objective measures trough time.
Copyright © 2018 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Clearance; Contact lens; Scleral lens

Mesh:

Year:  2018        PMID: 30501928     DOI: 10.1016/j.clae.2018.11.013

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  2 in total

1.  Practitioner Learning Curve in Fitting Scleral Lenses in Irregular and Regular Corneas Using a Fitting Trial.

Authors:  Rute J Macedo-de-Araújo; Eef van der Worp; José M González-Méijome
Journal:  Biomed Res Int       Date:  2019-01-28       Impact factor: 3.411

Review 2.  How Can We Best Measure the Performance of Scleral Lenses? Current Insights.

Authors:  Rute J Macedo-de-Araújo; Daddi Fadel; Melissa Barnett
Journal:  Clin Optom (Auckl)       Date:  2022-04-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.