Literature DB >> 3049718

Microleakage in class II composite restorations bonded to dentin using thermal and load cycling.

P A Darbyshire1, L B Messer, W H Douglas.   

Abstract

The effectiveness of a dentin-bonding agent (DBA) and a glass-ionomer cement liner (GIC) in reducing the marginal microleakage at the cervical margin of Class II posterior composite restorations was examined. The effect of load cycling on microleakage of this type of restoration was evaluated. The Class II cavities were prepared in extracted human pre-molar teeth, with the cervical margins finished approximately 1 mm below the CEJ. Combinations of DBA, GIC, and control (no liner) were used as mediators between resin and dentin. All restorations were placed incrementally with a 40-second cure per increment and finished with high-speed diamond burs. Half the samples of each treatment group received cyclical axial loading and half did not. All samples were thermocycled at 5 degrees and 55 degrees C for 500 cycles of one min each, stained (four hr) in 50% AgNO3, and sectioned following stain development. Microleakage was scored linearly along the dentin-restoration interface. All restorations exhibited microleakage which was unaffected by load cycling. Both the DBA and the GIC significantly reduced microleakage independently. When GIC was present, the additional presence of the DBA did not provide a statistically significant additional reduction of microleakage.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3049718     DOI: 10.1177/00220345880670031201

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  4 in total

1.  Effect of thermal cycling on whisker-reinforced dental resin composites.

Authors:  Hockin H K Xu; Frederick C Eichmiller; Douglas T Smith; Gary E Schumacher; Anthony A Giuseppetti; Joseph M Antonucci
Journal:  J Mater Sci Mater Med       Date:  2002-09       Impact factor: 3.896

2.  Evaluation of Microleakage of Dental Composites Using Bonding Agents with Different Placement Techniques: An Invitro Study.

Authors:  Jasvir Kaur; Deepika Kapoor; Deepanshu Garg; M K Sunil; Anshul Sawhney; Neha Malaviya; Shashank Tripathi; Saloni Arora
Journal:  J Clin Diagn Res       Date:  2015-09-01

3.  Finite element analysis of multi-piece post-crown restoration using different types of adhesives.

Authors:  Lin-Wei Lü; Guang-Wei Meng; Zhi-Hui Liu
Journal:  Int J Oral Sci       Date:  2013-07-26       Impact factor: 6.344

4.  Effect of Thermo-mechanical Load Cycling on Microleakage in Class II Ormocer Restorations.

Authors:  Dina Erdilek; Can Dörter; Fatma Koray; Karl-Heinz Kunzelmann; Begum Guray Efes; Yavuz Gomec
Journal:  Eur J Dent       Date:  2009-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.