Literature DB >> 30488108

Magnitude dependent discordance in liver stiffness measurements using elastography point quantification with transient elastography as the reference test.

Ivica Grgurevic1, Nermin Salkic2, Tonci Bozin3, Sanda Mustapic3, Vladimir Matic3, Ivo Dumic-Cule4, Ida Tjesic Drinkovic3, Tomislav Bokun3.   

Abstract

OBJECTIVES: To investigate diagnostic performance of point shear wave elastography by elastography point quantification (ElastPQ) for non-invasive assessment of liver fibrosis in patients with chronic liver diseases (CLD).
METHODS: Liver stiffness measurement (LSM) by transient elastography (TE) and ElastPQ was performed in patients with CLD and healthy volunteers. The stage of liver fibrosis was defined by TE which served as the reference. We compared two methods by using correlation, area under the receiver operating characteristics curve (AUC) analysis, Bland and Altman plot and Passing-Bablok regression.
RESULTS: A total of 185 subjects (20 healthy volunteers and 165 patients with CLD (128 non-alcoholic fatty liver disease), 83 (44.9%) females, median age 53 years, BMI 27.3 kg/m2) were evaluated. There were 24.3%, 13.5% and 11.4% patients in ≥ F2, ≥ F3 and F4 stage, respectively. The best performing cutoff LSM values by ElastPQ were 5.5 kPa for F ≥ 2 (AUC = 0.96), 8.1 kPa for F ≥ 3 (AUC = 0.98) and 9.9 kPa for F4 (AUC = 0.98). Mean (SD) difference between TE and ElastPQ measurements was 0.98 (3.27) kPa (95% CI 0.51-1.45, range 4.99-21.60 kPa). Two methods correlated significantly (r = 0.86; p < 0.001), yet Bland and Altman plot demonstrated difference between measurements, especially with TE values > 10 kPa. Passing and Bablok regression analysis yielded significant constant and proportional difference between ElastPQ and TE.
CONCLUSION: ElastPQ is reliable method for assessment of liver fibrosis but LSM values are not interchangeable with TE, especially above 10 kPa. Diagnostic performance of ElastPQ for sub-classification of patients with compensated advanced chronic liver disease should therefore be furtherly investigated. KEY POINTS: • ElastPQ appears to be reliable method for assessment of liver fibrosis, with data presented here mostly applicable to NAFLD. • LSM values produced by TE and ElastPQ are NOT interchangeable-in values < 10 kPa, they are similar, but in values > 10 kPa, they appear to be increasingly and significantly different. • Diagnostic performance of ElastPQ for sub-classification of patients with compensated advanced chronic liver disease should be furtherly investigated.

Entities:  

Keywords:  Diagnostic performance; Liver fibrosis; Liver stiffness measurement; Non-alcoholic fatty liver disease

Mesh:

Year:  2018        PMID: 30488108     DOI: 10.1007/s00330-018-5831-2

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  24 in total

1.  Differences in liver stiffness values obtained with new ultrasound elastography machines and Fibroscan: A comparative study.

Authors:  Fabio Piscaglia; Veronica Salvatore; Lorenzo Mulazzani; Vito Cantisani; Antonio Colecchia; Roberto Di Donato; Cristina Felicani; Alessia Ferrarini; Nesrine Gamal; Valentina Grasso; Giovanni Marasco; Elena Mazzotta; Federico Ravaioli; Giacomo Ruggieri; Ilaria Serio; Joules Fabrice Sitouok Nkamgho; Carla Serra; Davide Festi; Cosima Schiavone; Luigi Bolondi
Journal:  Dig Liver Dis       Date:  2017-03-10       Impact factor: 4.088

2.  EFSUMB guidelines and recommendations on the clinical use of ultrasound elastography. Part 2: Clinical applications.

Authors:  D Cosgrove; F Piscaglia; J Bamber; J Bojunga; J-M Correas; O H Gilja; A S Klauser; I Sporea; F Calliada; V Cantisani; M D'Onofrio; E E Drakonaki; M Fink; M Friedrich-Rust; J Fromageau; R F Havre; C Jenssen; R Ohlinger; A Săftoiu; F Schaefer; C F Dietrich
Journal:  Ultraschall Med       Date:  2013-04-19       Impact factor: 6.548

3.  Comparison between the M and XL probes for liver fibrosis assessment by transient elastography.

Authors:  Roxana Şirli; Ioan Sporea; Alexandra Deleanu; Laura Culcea; Milana Szilaski; Alina Popescu; Mirela Dănilă
Journal:  Med Ultrason       Date:  2014-06       Impact factor: 1.611

4.  WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 3: liver.

Authors:  Giovanna Ferraioli; Carlo Filice; Laurent Castera; Byung Ihn Choi; Ioan Sporea; Stephanie R Wilson; David Cosgrove; Christoph F Dietrich; Dominique Amy; Jeffrey C Bamber; Richard Barr; Yi-Hong Chou; Hong Ding; Andre Farrokh; Mireen Friedrich-Rust; Timothy J Hall; Kazutaka Nakashima; Kathryn R Nightingale; Mark L Palmeri; Fritz Schafer; Tsuyoshi Shiina; Shinichi Suzuki; Masatoshi Kudo
Journal:  Ultrasound Med Biol       Date:  2015-03-20       Impact factor: 2.998

5.  Accuracy of the ElastPQ Technique for the Assessment of Liver Fibrosis in Patients with Chronic Hepatitis C: a "Real Life" Single Center Study.

Authors:  Giovanna Ferraioli; Laura Maiocchi; Raffaella Lissandrin; Carmine Tinelli; Annalisa De Silvestri; Carlo Filice
Journal:  J Gastrointestin Liver Dis       Date:  2016-09       Impact factor: 2.008

6.  Non-invasive tests for fibrosis and liver stiffness predict 5-year survival of patients chronically infected with hepatitis B virus.

Authors:  V de Lédinghen; J Vergniol; C Barthe; J Foucher; F Chermak; B Le Bail; W Merrouche; P-H Bernard
Journal:  Aliment Pharmacol Ther       Date:  2013-04-05       Impact factor: 8.171

7.  Complications following percutaneous liver biopsy. A multicentre retrospective study on 68,276 biopsies.

Authors:  F Piccinino; E Sagnelli; G Pasquale; G Giusti
Journal:  J Hepatol       Date:  1986       Impact factor: 25.083

8.  Transient elastography: a new noninvasive method for assessment of hepatic fibrosis.

Authors:  Laurent Sandrin; Bertrand Fourquet; Jean-Michel Hasquenoph; Sylvain Yon; Céline Fournier; Frédéric Mal; Christos Christidis; Marianne Ziol; Bruno Poulet; Farad Kazemi; Michel Beaugrand; Robert Palau
Journal:  Ultrasound Med Biol       Date:  2003-12       Impact factor: 2.998

9.  Ultrasound point shear wave elastography assessment of liver and spleen stiffness: effect of training on repeatability of measurements.

Authors:  Giovanna Ferraioli; Carmine Tinelli; Raffaella Lissandrin; Mabel Zicchetti; Stefano Bernuzzi; Laura Salvaneschi; Carlo Filice
Journal:  Eur Radiol       Date:  2014-03-19       Impact factor: 5.315

10.  Prospective Comparison of Liver Stiffness Measurements between Two Point Shear Wave Elastography Methods: Virtual Touch Quantification and Elastography Point Quantification.

Authors:  Hyunsuk Yoo; Jeong Min Lee; Jeong Hee Yoon; Dong Ho Lee; Won Chang; Joon Koo Han
Journal:  Korean J Radiol       Date:  2016-08-23       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.