Literature DB >> 30487238

The attenuated spline reconstruction technique for single photon emission computed tomography.

Nicholas E Protonotarios1,2, Athanassios S Fokas3,4,5, Kostas Kostarelos6,7, George A Kastis3.   

Abstract

We present the attenuated spline reconstruction technique (aSRT) which provides an innovative algorithm for single photon emission computed tomography (SPECT) image reconstruction. aSRT is based on an analytic formula of the inverse attenuated Radon transform. It involves the computation of the Hilbert transforms of the linear attenuation function and of two sinusoidal functions of the so-called attenuated sinogram These computations are achieved by employing the attenuation information provided by computed tomography (CT) scans and by utilizing custom-made cubic spline interpolation. The purpose of this work is: (i) to present the mathematics of aSRT, (ii) to reconstruct simulated and real SPECT/CT data using aSRT and (iii) to evaluate aSRT by comparing it to filtered backprojection (FBP) and to ordered subsets expectation minimization (OSEM) reconstruction algorithms. Simulation studies were performed by using an image quality phantom and an appropriate attenuation map. Reconstructed images were generated for 45, 90 and 180 views over 360 degrees with 20 realizations and involved Poisson noise of three different levels (NL), namely 100% (NL1), 50% (NL2) and 10% (NL3) of the total counts, respectively. Moreover, real attenuated SPECT sinograms were reconstructed from a real study of a Jaszczak phantom, as well as from a real clinical myocardial SPECT/CT study. Comparisons between aSRT, FBP and OSEM reconstructions were performed using contrast, bias and image roughness. The results suggest that aSRT can efficiently produce accurate attenuation-corrected reconstructions for simulated and real phantoms, as well as for clinical data. In particular, in the case of the clinical myocardial study, aSRT produced reconstructions with higher cold contrast than both FBP and OSEM. aSRT, by incorporating the attenuation correction within itself, may provide an improved alternative to FBP. This is particularly promising for 'cold' regions as those occurring in myocardial ischaemia.
© 2018 The Author(s).

Entities:  

Keywords:  analytic image reconstruction; attenuated Radon transform; single photon emission computed tomography (SPECT)

Mesh:

Year:  2018        PMID: 30487238      PMCID: PMC6283982          DOI: 10.1098/rsif.2018.0509

Source DB:  PubMed          Journal:  J R Soc Interface        ISSN: 1742-5662            Impact factor:   4.118


  11 in total

Review 1.  Attenuation correction, or the emperor's new clothes?

Authors:  F J Wackers
Journal:  J Nucl Med       Date:  1999-08       Impact factor: 10.057

2.  The SRT reconstruction algorithm for semiquantification in PET imaging.

Authors:  George A Kastis; Anastasios Gaitanis; Alexandros P Samartzis; Athanasios S Fokas
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

Review 3.  Attenuation correction: eternal dilemma or real improvement?

Authors:  R C Hendel
Journal:  Q J Nucl Med Mol Imaging       Date:  2005-03       Impact factor: 2.346

4.  Reconstruction algorithm for single photon emission computed tomography and its numerical implementation.

Authors:  A S Fokas; A Iserles; V Marinakis
Journal:  J R Soc Interface       Date:  2006-02-22       Impact factor: 4.118

5.  Attenuation correction in cardiac SPECT: the boy who cried wolf?

Authors:  Guido Germano; Piotr J Slomka; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2007-01       Impact factor: 5.952

6.  A unified analysis of exact methods of inverting the 2-D exponential radon transform, with implications for noise control in SPECT.

Authors:  C E Metz; X Pan
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

Review 7.  A review on the clinical uses of SPECT/CT.

Authors:  Giuliano Mariani; Laura Bruselli; Torsten Kuwert; Edmund E Kim; Albert Flotats; Ora Israel; Maurizio Dondi; Naoyuki Watanabe
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-02-25       Impact factor: 9.236

8.  Attenuation correction for myocardial perfusion SPECT imaging: still a controversial issue.

Authors:  Alberto Cuocolo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-08-27       Impact factor: 9.236

9.  Evaluation of the spline reconstruction technique for PET.

Authors:  George A Kastis; Dimitra Kyriakopoulou; Anastasios Gaitanis; Yolanda Fernández; Brian F Hutton; Athanasios S Fokas
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

10.  Application of Chang's attenuation correction technique for single-photon emission computed tomography partial angle acquisition of Jaszczak phantom.

Authors:  Krishnendu Saha; Sean C Hoyt; Bryon M Murray
Journal:  J Med Phys       Date:  2016 Jan-Mar
View more
  1 in total

1.  Effectiveness of the smoothing filter in pediatric 99mTc-dimercaptosuccinic acid renal scintigraphy.

Authors:  Hitoshi Saito; Teruhiro Ito; Koichi Omachi; Atsushi Inugami; Masaru Yamaguchi; Megumi Tsushima; Yasushi Mariya; Ikuo Kashiwakura
Journal:  Radiol Phys Technol       Date:  2020-01-29
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.