Literature DB >> 30480597

The Stability of the Porous Tantalum Components Used in Revision THA to Treat Severe Acetabular Defects: A Radiostereometric Analysis Study.

Lucian B Solomon1,2, John M Abrahams1,2, Stuart A Callary1,2, Donald W Howie1,2.   

Abstract

BACKGROUND: The acetabular components used in revision total hip arthroplasty (THA) to treat severe acetabular bone defects have high rates of re-revision at mid to long-term follow-up. Early translation of acetabular components used in revision THA is a good predictor of later loosening, and radiostereometric analysis (RSA) is the most sensitive method to measure migration. The objectives of the present study were to use RSA to compare the migration of the porous tantalum acetabular components used to treat severe bone defects with the previously established acceptable proximal translation threshold of ≤1 mm within 2 years, and to determine the effect on migration of the addition of inferior screws through the component into the ischium or pubis.
METHODS: RSA was utilized to measure the migration of 55 porous tantalum components used to treat severe acetabular defects (28 Paprosky IIIA, 27 Paprosky IIIB; 21 hips with pelvic discontinuity) at a mean follow-up of 4 years (range, 2 to 12 years).
RESULTS: Forty-eight of the 55 components migrated less than the threshold that predicts later loosening (>1 mm) and 50 had not been re-revised at the time of the latest follow-up. Seven components, none of which had inferior screw fixation, exceeded the translation threshold. Of these, 6 were implanted to treat pelvic discontinuity. Of those 6 components, 5 were re-revised for loosening related to patient symptoms. At 2 years, the absolute median proximal translation of components with inferior screw fixation was |0.3| mm (range, |0.1| to |0.9| mm), compared with |0.4| mm (range, |0.03| to |16.4| mm) for those without inferior screws (p = 0.04).
CONCLUSIONS: As measured with use of RSA, the majority of porous tantalum acetabular components used in a revision THA to treat severe acetabular defects had acceptable early migration. This predicts good long-term survivorship of these components. The use of inferior screws further improved acetabular component fixation. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30480597     DOI: 10.2106/JBJS.18.00127

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  6 in total

1.  Minimum 2-Year Outcomes of a Novel 3D-printed Fully Porous Titanium Acetabular Shell in Revision Total Hip Arthroplasty.

Authors:  Elyse J Berlinberg; J Abraham Kavian; Mackenzie A Roof; Ittai Shichman; Brett Frykberg; William B Lutes; Erik A Schnaser; Stephen A Jones; Richard W McCalden; Ran Schwarzkopf
Journal:  Arthroplast Today       Date:  2022-10-12

Review 2.  The Diagnosis and Treatment of Acetabular Bone Loss in Revision Hip Arthroplasty: An International Consensus Symposium.

Authors:  Peter K Sculco; Timothy Wright; Michael-Alexander Malahias; Alexander Gu; Mathias Bostrom; Fares Haddad; Seth Jerabek; Michael Bolognesi; Thomas Fehring; Alejandro Gonzalez DellaValle; William Jiranek; William Walter; Wayne Paprosky; Donald Garbuz; Thomas Sculco
Journal:  HSS J       Date:  2021-09-28

3.  A novel revision system for complex pelvic defects utilizing 3D-printed custom prosthesis.

Authors:  Yongqiang Hao; Dinghao Luo; Junxiang Wu; Lei Wang; Kai Xie; Mengning Yan; Kerong Dai; Yongqiang Hao
Journal:  J Orthop Translat       Date:  2021-12-15       Impact factor: 5.191

4.  Acetabular Revision Arthroplasty Based on 3-Dimensional Reconstruction Technology Using Jumbo Cups.

Authors:  Xianyue Shen; Hao Tian; Yang Li; Jianlin Zuo; Zhongli Gao; Jianlin Xiao
Journal:  Front Bioeng Biotechnol       Date:  2022-04-05

5.  Extended Ischiopubic Fixation Using Porous Metal Augments in Cementless Acetabular Reconstruction during Revision Total Hip Arthroplasty.

Authors:  Yong Huang; Hao Tang; Yixin Zhou; Hongyi Shao; Dejin Yang; Baochun Zhou
Journal:  Orthop Surg       Date:  2022-08-26       Impact factor: 2.279

6.  Defining the canal for ischial and pubic screws in cup revision surgery.

Authors:  Steffen Brodt; Vincent Boersch; Patrick Strube; Georgi Wassilew; Georg Matziolis
Journal:  Int Orthop       Date:  2022-08-22       Impact factor: 3.479

  6 in total