| Literature DB >> 30479980 |
Ahmad Mehri1, Somayeh Farhang Dehghan2, Milad Abbasi3,4, Mohammad Hosein Beheshti5, Javad Sajedifar6, Sayed Mohammad Jafari7, Monireh Khadem8, Roohalah Hajizadeh9.
Abstract
Background: The purpose of this study was to assess the contrast perception of obstacles in a tunnel entrance which was placed in Ilam Province, Iran.Entities:
Keywords: Contrast perception; Ilam; Safe stopping distance; Tunnel entrance
Year: 2018 PMID: 30479980 PMCID: PMC6249494 DOI: 10.15171/hpp.2018.38
Source DB: PubMed Journal: Health Promot Perspect ISSN: 2228-6497
Figure 1Rings angle of the Holladay polar diagram
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 | 3 | 4 | 5.8 | 8 | 11.6 | 16.6 | 24 | 36 | 56.8 |
Figure 2
Figure 3
Figure 4Estimation of the luminance in each sector of the polar diagram based on CIE-088-2004 standard
|
|
|
|
| ||
|
|
|
| |||
| South | 5 | 0 | 1 | 4 | 2 |
The luminance for each sector of the rings of the Holladay diagram in the south line of the tunnel entrance
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
| |
| 1 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | Not calculated |
| 2 | 0 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
| 3 | 0 | 0 | 0 | 2.9 | 4.4 | 4.7 | 4.3 | 4.7 | 4.7 |
| 4 | 0 | 0 | 0 | 0.2 | 3.7 | 2.8 | 1 | 1 | 1 |
| 5 | 0 | 0 | 0 | 0 | 0.95 | 1 | 1 | 1 | 1.8 |
| 6 | 0 | 0 | 0 | 0.05 | 1 | 1 | 1 | 1.5 | Not calculated |
| 7 | 0 | 0 | 0 | 0.1 | 1 | 1 | 1 | 1.6 | Not calculated |
| 8 | 0 | 0 | 0 | 0 | 0.55 | 1 | 1 | 1.1 | 2 |
| 9 | 0 | 0 | 0 | 0 | 3.5 | 3.6 | 1.15 | 1 | 1.02 |
| 10 | 0 | 0 | 0 | 2.5 | 4.5 | 4.8 | 4.8 | 4.8 | 4.8 |
| 11 | 0 | 2.5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
| 12 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | Not calculated |
| Luminance of each ring | 10 | 17.5 | 20 | 25.75 | 39.6 | 39.9 | 35.25 | 36.7 | 25.32 |
| Luminance of all rings | ∑Lije = 250.02 Kcd/m2 | ||||||||