Literature DB >> 3047864

[Risks of fine needle puncture--results of a survey in West Germany(German Society of Ultrasound in Medicine survey)].

H Weiss1, U Düntsch, A Weiss.   

Abstract

The rate of complications in fine needle puncture was ascertained by an inquiry conducted among the members of the German Association of Ultrasound in Medicine (DEGUM). 337 complications had been registered in a total of 66,397 punctures, corresponding to a percentage of only 0.51%. 294 of these were mild, i.e. not requiring therapy (0.44%), 38 severe (0.057%) and 5 complications were fatal and resulted in death (0.0075%). Differences were slight in respect of the frequency of complications with reference to puncture technique and type of needle employed. Most complications were seen in fine needle puncture for obtaining histological material (0.67%) (cutting biopsy needles), compared with 0.54% in therapeutic puncture and 0.46% for obtaining cytological material. Among the puncture techniques, the use of a puncture transducer resulted in more complications (0.72%) compared with sonographically guided puncture (0.59%) and puncture in full view with 0.43%. Punctures with/fatal outcome had been conducted in 4 out 5 cases with so-called cutting biopsy needles. Results are identical with those obtained in the U.S.A. on a comparative basis. Compared with punctures with so-called coarse needles, fine needle puncture results in fewer complications on account of the smaller needle caliber. As with every intensive method, however, complications must be taken into account even with fine needle puncture.

Entities:  

Mesh:

Year:  1988        PMID: 3047864     DOI: 10.1055/s-2007-1011609

Source DB:  PubMed          Journal:  Ultraschall Med        ISSN: 0172-4614            Impact factor:   6.548


  7 in total

1.  Needle track seeding following percutaneous procedures for hepatocellular carcinoma.

Authors:  Giuseppe Cabibbo; Antonio Craxì
Journal:  World J Hepatol       Date:  2009-10-31

2.  Two cases of lethal complications following ultrasound-guided percutaneous fine-needle biopsy of the liver.

Authors:  I Drinković; B Brkljacić
Journal:  Cardiovasc Intervent Radiol       Date:  1996 Sep-Oct       Impact factor: 2.740

3.  Diagnosis of HCC.

Authors:  C K Leow; W Y Lau
Journal:  Dig Dis Sci       Date:  1997-10       Impact factor: 3.199

4.  [Indications for pancreatic biopsy. Uncommon, but increasingly more important].

Authors:  J-M Löhr; G Klöppel
Journal:  Pathologe       Date:  2005-02       Impact factor: 1.011

5.  Fine needle trucut biopsy of focal liver lesions: a new technique.

Authors:  I Duysburgh; P Michielsen; H Fierens; E Van Marck; P Pelckmans
Journal:  Dig Dis Sci       Date:  1997-10       Impact factor: 3.199

6.  Ultrasound guided fine needle biopsy of early hepatocellular carcinoma complicating liver cirrhosis: a multicentre study.

Authors:  E Caturelli; L Solmi; M Anti; S Fusilli; P Roselli; A Andriulli; F Fornari; C Del Vecchio Blanco; I de Sio
Journal:  Gut       Date:  2004-09       Impact factor: 23.059

Review 7.  Assessment of pancreatic neoplasms: review of biopsy techniques.

Authors:  Steven B Goldin; Michael W Bradner; Emmanuel E Zervos; Alexander S Rosemurgy
Journal:  J Gastrointest Surg       Date:  2007-06       Impact factor: 3.267

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.