First-in-man pulmonary artery stenting in children using the Bentley® BeGrow™ stent system for newborns and infants.

Daniel Quandt1, Walter Knirsch2, Ina Michel-Behnke3, Erwin Kitzmüller3, Miko Obradovic4, Frank Uhlemann5, Oliver Kretschmar2.   

Abstract

BACKGROUND: Stent implantation into growing vessels is a common treatment option in infants and children with congenital heart disease (CHD) and corresponding vessel lesions. After stent implantation in small children, repetitive stent redilations are frequently necessary to accommodate for somatic growth. Until now, all available stents have limited final expansion diameters. MATERIAL AND
RESULTS: The new Bentley BeGrow™ stent system for newborns and infants is a L605 cobalt‑chromium, pre-mounted, balloon expandable stent, which is compatible with a 4 French sheath and 0.014 inch guide wire thus allowing implantation in small vessels (4-6 mm). It offers a new, unique stent design that allows post-dilation steps up to Ø11.5 mm. While re-dilating up to Ø11.5 mm this new stent maintains radial force and shows uniform expansion with only minimal foreshortening. Predetermined breaking points allow the stent struts to break in a controlled manner when exceeding a diameter of 11.5 mm. Residual radial force maintains even after stent opening due to spiral arrangement of the predetermined breaking points. The 2 first-in-man pulmonary artery stent implantations in a newborn with univentricular circulation and a toddler with biventricular circulation are reported as part of the currently performed licencing trial (ClinicalTrials.govNCT03287024).
CONCLUSION: The low-profile BeGrow™ stent system offers new treatment options for transcatheter stent implantations in newborns and infants. In our first experience, it can be effectively implanted. Longer follow-up will evaluate multiple, stepwise redilations and controlled stent strut breakage, which have the potential to accommodate for somatic vessel growth and/or subsequent implantation of larger stents.
Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2018        PMID: 30477928     DOI: 10.1016/j.ijcard.2018.11.029

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  2 in total

Review 1.  Transcatheter Device Therapy and the Integration of Advanced Imaging in Congenital Heart Disease.

Authors:  Abhay A Divekar; Yousef M Arar; Stephen Clark; Animesh Tandon; Thomas M Zellers; Surendranath R Veeram Reddy
Journal:  Children (Basel)       Date:  2022-04-02

2.  Preliminary testing and evaluation of the renata minima stent, an infant stent capable of achieving adult dimensions.

Authors:  Evan M Zahn; Eason Abbott; Neil Tailor; Shyam Sathanandam; Dustin Armer
Journal:  Catheter Cardiovasc Interv       Date:  2021-05-04       Impact factor: 2.585