Literature DB >> 30477813

Management of anteromedially displaced acetabular fractures using a collinear reduction clamp through modified ilioinguinal approach.

Chul-Young Jang1, Dae-Kyung Kwak1, Hyung-Min Lee1, Ji-Hyo Hwang2, Je-Hyun Yoo3.   

Abstract

The authors present a surgical technique using a collinear reduction clamp through the modified ilioinguinal approach (MIA) for anteromedially displaced acetabular fractures along with the surgical outcomes. Between October 2010 and June 2015, 15 patients underwent surgical treatment for anteromedially displaced acetabular fractures; 10 both-column fractures and 5 anterior column and posterior hemitransverse fractures. Anteriorly displaced anterior column fragment and medially displaced quadrilateral plate fragment were simultaneously reduced using a collinear clamp and fixed with a 3.5mm-reconstruction plate through MIA. Postoperatively, anatomical reduction was achieved in 12 patients, while imperfect reduction was achieved in 3. At a mean follow-up of 49.0 months (range, 24-93 months), the mean Postel Merle d'Aubigné score were 16.3 and the mean VAS score was 0.9. Final radiographic grades according to Matta system were excellent in 13 patients and good in 2. Surgical technique using a collinear reduction clamp through the MIA can provide satisfactory outcomes in anteromedially displaced acetabular fractures.
Copyright © 2018 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Acetabular fracture; Anteromedially displaced; Collinear reduction clamp; Modified ilioinguinal approach

Mesh:

Year:  2018        PMID: 30477813     DOI: 10.1016/j.otsr.2018.10.004

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  2 in total

1.  Supra-ilioinguinal versus modified Stoppa approach in the treatment of acetabular fractures: reduction quality and early clinical results of a retrospective study.

Authors:  Sheng Yao; Kaifang Chen; Yanhui Ji; Fengzhao Zhu; Lian Zeng; Zekang Xiong; Tingfang Sun; Fan Yang; Jia Liu; Xiaodong Guo
Journal:  J Orthop Surg Res       Date:  2019-11-14       Impact factor: 2.359

2.  Comparison of three different reduction methods of the ankle mortise in unstable syndesmotic injuries.

Authors:  Sven Yves Vetter; Nils Beisemann; Holger Keil; Marc Schnetzke; Benedict Swartman; Jochen Franke; Paul Alfred Grützner; Maxim Privalov
Journal:  Sci Rep       Date:  2019-10-28       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.