Literature DB >> 30476592

Rapid liquid chromatography-tandem mass spectrometry method for determination of 24,25(OH)2D and 25OHD with efficient separation of 3-epi analogs.

Songlin Yu1, Weiyan Zhou2, Danchen Wang1, Yicong Yin1, Qian Cheng1, Shaowei Xie1, Dandan Sun1, Honglei Li1, Xinqi Cheng1, Ling Qiu3.   

Abstract

This study establishes and validates a rapid method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) without derivatization steps to simultaneously measure of 24,25(OH)2D2, 24,25(OH)2D3, 25OHD2, and 25OHD3, while efficiently separating the 3-epi analogs. Samples were prepared by precipitation and liquid-liquid extraction. The linearity, precision, accuracy, recovery and matrix effect of the method were thoroughly evaluated according to the Clinical & Laboratory Standards Institute guidelines. Additionally, the four vitamin D metabolites in the serum of 38 apparently healthy Chinese volunteers were evaluated. The total analysis time was 8.0 min, with efficient separation of 3-epi 24,25(OH)2D3 and 3-epi 25OHD3, without interference from isomers such as 23,25(OH)2D3 or 1,25(OH)2D2, 1,25(OH)2D3. Good reproducibility was obtained for all four metabolites with within-run coefficient variations (CVs) of 4.07%-6.55%, 4.26%-7.84%, 2.46%-7.21%, and 4.90%-6.87% for 25OHD3, 25OHD2, 24,25(OH)2D3, and 24,25(OH)2D2, respectively, and the total CVs were 4.29%-6.64%, 6.14%-7.84%, 4.33%-7.21%, 5.82%-9.90%, respectively. The limit of quantification was 0.625 ng/mL for 25OHD3 and 25OHD2, and 0.5 ng/mL for 24,25(OH)2D3 and 24,25(OH)2D2. The relative bias of the LC-MS/MS method compared to the certified results of SRM 972a for 25OHD3, 25OHD2 and 24,25(OH)2D3 was -2.21% to 1.01%, 3.38% to 6.73%, and -7.72% to -3.9%, respectively. The mean±SD values for 25OHD, 24,25(OH)2D and 25OHD/24,25(OH)2D in the volunteers were 13.5±4.4 ng/mL(range:7.6-27.5 ng/mL), 0.84±0.42 ng/mL (range:0.26-2.1 ng/mL), and 18±7(range:8-37), respectively. Thus, a simple, precise LC-MS/MS method for appropriate retention and separation of vitamin D metabolites and their epi analogs was developed.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Interference; Liquid chromatography/tandem mass spectrometry; Matrix effect; Metabolite; Vitamin D

Mesh:

Substances:

Year:  2018        PMID: 30476592     DOI: 10.1016/j.jsbmb.2018.11.012

Source DB:  PubMed          Journal:  J Steroid Biochem Mol Biol        ISSN: 0960-0760            Impact factor:   4.292


  2 in total

Review 1.  Sample preparation techniques for extraction of vitamin D metabolites from non-conventional biological sample matrices prior to LC-MS/MS analysis.

Authors:  Anastasia Alexandridou; Dietrich A Volmer
Journal:  Anal Bioanal Chem       Date:  2022-05-02       Impact factor: 4.478

Review 2.  Vitamin D: Current Challenges between the Laboratory and Clinical Practice.

Authors:  Ludmila Máčová; Marie Bičíková
Journal:  Nutrients       Date:  2021-05-21       Impact factor: 5.717

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.