Correction: On the internal reaction forces, energy absorption, and fracture in the hip during simulated sideways fall impact.

Ingmar Fleps, William S Enns-Bray, Pierre Guy, Stephen J Ferguson, Peter A Cripton, Benedikt Helgason.   

Abstract

[This corrects the article DOI: 10.1371/journal.pone.0200952.].

Entities:  

Year:  2018        PMID: 30475925      PMCID: PMC6258374          DOI: 10.1371/journal.pone.0208286

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


In Fig 2, the markers PB1 and PB2 are incorrect. PB1 should be labeled LR1 and PB2 should be labeled LR2. Additionally, the marker dPB should be removed. Please see the corrected Fig 2 here.
Fig 2

FEM of specimen H1391 aligned in initial position corresponding to the time of first contact with force plate during the experimental testing.

Lower limb constructions coloured grey, lower limb masses coloured blue and soft tissue coloured orange. Marker points corresponding to location of video markers of the physical specimen are shown in black. Marker ST1 corresponds to a marker attached to the surrogate soft tissue above the right GT. Markers LR1 and LR2 correspond to the position of markers attached to the right and left side of the pelvic ring, respectively.

FEM of specimen H1391 aligned in initial position corresponding to the time of first contact with force plate during the experimental testing.

Lower limb constructions coloured grey, lower limb masses coloured blue and soft tissue coloured orange. Marker points corresponding to location of video markers of the physical specimen are shown in black. Marker ST1 corresponds to a marker attached to the surrogate soft tissue above the right GT. Markers LR1 and LR2 correspond to the position of markers attached to the right and left side of the pelvic ring, respectively.
  1 in total

1.  On the internal reaction forces, energy absorption, and fracture in the hip during simulated sideways fall impact.

Authors:  Ingmar Fleps; William S Enns-Bray; Pierre Guy; Stephen J Ferguson; Peter A Cripton; Benedikt Helgason
Journal:  PLoS One       Date:  2018-08-16       Impact factor: 3.240

  1 in total
  2 in total

1.  The Influence of Fall Direction and Hip Protector on Fracture Risk: FE Model Predictions Driven by Experimental Data.

Authors:  Ellie S Galliker; Andrew C Laing; Stephen J Ferguson; Benedikt Helgason; Ingmar Fleps
Journal:  Ann Biomed Eng       Date:  2022-02-07       Impact factor: 3.934

2.  One step further in biomechanical models in palaeontology: a nonlinear finite element analysis review.

Authors:  Jordi Marcé-Nogué
Journal:  PeerJ       Date:  2022-08-08       Impact factor: 3.061

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.