Literature DB >> 30475420

Comparison of three different stents for endoscopic ultrasound-guided drainage of pancreatic fluid collection: A large retrospective study.

Zhijie Wang1,2, Shengbing Zhao1, Qianqian Meng1, Shuling Wang1, Yan Chen1, Fuming Wang3, Qiang Li4, Jun Yao5, Yiqi Du1, Zhendong Jin1, Yu Bai1, Zhaoshen Li1, Dong Wang1,2.   

Abstract

BACKGROUND AND AIM: Endoscopic transmural drainage has been recognized as the first-line treatment for pancreatic fluid collection (PFC). Currently, three different types of stents have been extensively applied, including double pigtail plastic stent (PS), fully covered self-expanding metal stent (FCSEMS), and novel lumen-apposing metal stent (LAMS). Nonetheless, limited data are available about the comparison among them in terms of their clinical outcomes and safety for endoscopic ultrasound-guided drainage of PFC.
METHODS: The current retrospective study was carried on 160 PFC patients undergoing endoscopic ultrasound-guided drainage from 2010 to 2018 at a single tertiary care center. Patients were divided into three groups based on different drainage ways: drainage using PS, FCSEMS, or LAMS.
RESULTS: A total of 160 PFC patients (104 male and 56 female) were analyzed in this retrospective study, including 62 patients drained with PS, 28 with FCSEMS, and 70 with LAMS. Typically, the technical success (93.5% vs 96.4% vs 94.3%, P = 1.000) and treatment success rates (84.6% vs 85.2% vs 89.2%, P = 0.763) were similar between PS, FCSEMS, and LAMS. With regard to major adverse events, four patients (FCSEMS: n = 2 and LAMS: n = 2) with pseudoaneurysms developed severe bleeding; among them, 75% (3/4) of patients were observed within 2 weeks after intervention, and two patients in LAMS group died.
CONCLUSIONS: There are no significant differences in the clinical outcomes of PFC patients treated with PS, FCSEMS, or LAMS. Nonetheless, severe (or even fatal) bleeding may occur at the early stage after metal stent placement, which should be paid particular attention to.
© 2018 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

Entities:  

Keywords:  adverse event; bleeding; endoscopic drainage; lumen-apposing metal stent; pancreatic fluid collection

Mesh:

Year:  2019        PMID: 30475420     DOI: 10.1111/jgh.14557

Source DB:  PubMed          Journal:  J Gastroenterol Hepatol        ISSN: 0815-9319            Impact factor:   4.029


  7 in total

1.  Predictors of the need for necrosectomy in patients with walled-off pancreatic necrosis treated with lumen apposition metal stents.

Authors:  Laura González-González; Sergio Bazaga; Marianette Murzi; Anna Brujats; Mireia Trias; Beatriz de Riba; Raffaella Romito; Juan Colán-Hernández; Mar Concepción; Jordi Gordillo; Juan Carlos Pernas; Maria Poca; German Soriano; Carlos Guarner-Argente
Journal:  Surg Endosc       Date:  2021-03-03       Impact factor: 4.584

2.  Efficacy and safety of plastic versus lumen-apposing metal stents for transmural drainage of walled-off necrosis: a retrospective single-center study.

Authors:  Surinder Singh Rana; Ravi Sharma; Lovneet Dhalaria; Rajesh Gupta
Journal:  Ann Gastroenterol       Date:  2020-05-25

Review 3.  Endoscopic Transmural Necrosectomy: Timing, Indications, and Methods.

Authors:  Rungsun Rerknimitr
Journal:  Clin Endosc       Date:  2019-09-18

Review 4.  Are Lumen-Apposing Metal Stents More Effective Than Plastic Stents for the Management of Pancreatic Fluid Collections: An Updated Systematic Review and Meta-analysis.

Authors:  Shali Tan; Chunyu Zhong; Yutang Ren; Xujuan Luo; Jin Xu; Yan Peng; Xiangsheng Fu; Xiaowei Tang
Journal:  Gastroenterol Res Pract       Date:  2020-04-20       Impact factor: 2.260

5.  Endoscopic Transmural Drainage and Necrosectomy in Acute Necrotizing Pancreatitis: A Review.

Authors:  Linlin Feng; Jintao Guo; Sheng Wang; Xiang Liu; Nan Ge; Guoxin Wang; Siyu Sun
Journal:  J Transl Int Med       Date:  2021-09-28

6.  Comparative Effectiveness of Lumen-Apposing Metal Stents and Plastic Stents for the Treatment of Pancreatic Walled-Off Necrosis: A Meta-analysis.

Authors:  Natalia Causada Calo; Kirles Bishay; Mohammad Yaghoobi; Yuhong Yuan; Jeffrey Mosko; Gary May; Yen-I Chen; Christopher Teshima
Journal:  J Can Assoc Gastroenterol       Date:  2021-08-07

7.  Lumen-apposing metal stent placement for drainage of pancreatic fluid collections: predictors of adverse events.

Authors:  Ji Young Bang; Robert H Hawes; Shyam Varadarajulu
Journal:  Gut       Date:  2020-02-17       Impact factor: 23.059

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.