Literature DB >> 3047442

Duplex ultrasound assessment of venous diameters, peak velocities, and flow patterns.

G L Moneta1, G Bedford, K Beach, D E Strandness.   

Abstract

Duplex ultrasound was used to study the diameters, flow patterns, and peak blood flow velocities of the common femoral vein (CFV) in 12 normal subjects (mean age 35 years). Each subject was supine and non-weight-bearing on a tilt table and rotated in 10-degree increments from -10 degrees (head down) to +30 degrees (head up). Cross-sectional B-mode image was used to monitor continuously CFV diameter for 5 minutes in each position. Doppler flow patterns were recorded in longitudinal axis; heart rate and respiratory movements were also noted. CFV flow was affected by respiratory and cardiac events. At -10 degrees flow was primarily related to cardiac events, with flow increasing during diastole. At +30 degrees flow varied minimally with the cardiac cycle and was primarily respiration dependent, stopping at peak inspiration. Proceeding from -10 to +30 degrees the mean maximal CFV diameter corrected for body surface area increased 92% (0.47 +/- 0.11 cm/m2 to 0.90 +/- 0.16 cm/m2, p less than 0.001), whereas peak flow velocity decreased from 41 +/- 10 cm/sec to 13 +/- 5 cm/sec, p less than 0.001. There was a linear, inverse relationship between mean peak velocity and mean corrected diameter, r = -0.99. The study confirms the multiple influences on venous flow patterns and establishes a quantitative relationship between venous diameters and flow velocities.

Mesh:

Year:  1988        PMID: 3047442     DOI: 10.1067/mva.1988.avs0080286

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  6 in total

1.  A geometrically adaptable heart valve replacement.

Authors:  Sophie C Hofferberth; Mossab Y Saeed; Lara Tomholt; Matheus C Fernandes; Christopher J Payne; Karl Price; Gerald R Marx; Jesse J Esch; David W Brown; Jonathan Brown; Peter E Hammer; Richard W Bianco; James C Weaver; Elazer R Edelman; Pedro J Del Nido
Journal:  Sci Transl Med       Date:  2020-02-19       Impact factor: 17.956

2.  Diameter and blood velocity changes in the saphenous vein during thermal stress.

Authors:  P Abraham; G Leftheriotis; B Desvaux; M Saumet; J L Saumet
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1994

3.  Efficacy and safety of enoxaparin for preventing venous thromboembolic events after laparoscopic colorectal cancer surgery: a randomized-controlled trial (YCOG 1404).

Authors:  Kazuya Nakagawa; Jun Watanabe; Mitsuyoshi Ota; Yusuke Suwa; Shinsuke Suzuki; Hirokazu Suwa; Masashi Momiyama; Atsushi Ishibe; Yusuke Saigusa; Takeharu Yamanaka; Chikara Kunisaki; Itaru Endo
Journal:  Surg Today       Date:  2019-08-05       Impact factor: 2.549

4.  Pulmonary embolism following laparoscopic antireflux surgery: a case report and review of the literature.

Authors:  N T Nguyen; J D Luketich; D M Friedman; S Ikramuddin; P R Schauer
Journal:  JSLS       Date:  1999 Apr-Jun       Impact factor: 2.172

5.  Effect of valve lesion on venous valve cycle: A modified immersed finite element modeling.

Authors:  Xiang Liu; Lisheng Liu
Journal:  PLoS One       Date:  2019-03-04       Impact factor: 3.240

6.  Biohybrid elastin-like venous valve with potential for in situ tissue engineering.

Authors:  Fernando González-Pérez; Sergio Acosta; Stephan Rütten; Caroline Emonts; Alexander Kopp; Heinz-Werner Henke; Philipp Bruners; Thomas Gries; J Carlos Rodríguez-Cabello; Stefan Jockenhoevel; Alicia Fernández-Colino
Journal:  Front Bioeng Biotechnol       Date:  2022-09-21
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.