Literature DB >> 30474243

Use of TiBrush for surface decontamination at peri-implantitis sites in dogs: Radiographic and histological outcomes.

Paolo Viganò1, Karol A Apaza Alccayhuaman1, Shigeru Sakuma1, Yoshiyuki Amari1, Franco Bengazi1,2, Daniele Botticelli1,2.   

Abstract

AIM: The aim of the present study was to evaluate the efficacy on the healing of mechanical decontamination of infected implant surfaces performed with a titanium brush.
METHODS: Mandibular premolars and first molars were extracted bilaterally in six dogs. After 3 months, two unsubmerged implants were installed on both sides of the mandible. Three months later, peri-implantitis was induced with ligatures for 3 months and then removed. After 1 month, surgical mechanical decontamination of the surfaces was performed either with a rotatory titanium brush or gauzes soaked in saline. Five month later, biopsies were retrieved. Evaluations on X-rays taken of the mesiodistal plane and on histological slides prepared in a buccal-lingual plane were performed.
RESULTS: After the induction of peri-implantitis, a mean marginal bone loss of 2.6 ± 0.6 mm and 1.9 ± 1.0 mm was observed in the brush and gauze groups by X-ray, respectively. Five months after treatment, a mean gain of marginal bone of 0.6 mm was obtained in both groups. The mean closures of the vertical and horizontal defects were 0.6 mm and 0.6 mm for the brush group, and 0.8 mm and 0.5 mm for the gauze group, respectively. Histologically, a loss of attachment at the buccal aspect of 2.2 ± 0.9 mm in the brush group and of 2.3 ± 0.5 mm in the gauze group was found. No statistically-significant differences were found after the treatment.
CONCLUSIONS: Mechanical implant surface decontamination performed with a rotatory titanium brush resulted in a marginal bone level gain, yielding a low content of inflammatory infiltrate close to the marginal bone.
© 2018 John Wiley & Sons Australia, Ltd.

Entities:  

Keywords:  animal experiment; decontamination; hstological assessment; peri-implantitis; surgical procedure

Mesh:

Substances:

Year:  2018        PMID: 30474243     DOI: 10.1111/jicd.12378

Source DB:  PubMed          Journal:  J Investig Clin Dent        ISSN: 2041-1618


  3 in total

1.  Comparison of the structure and function of a chimeric peptide modified titanium surface.

Authors:  Lei Gong; Hongjuan Geng; Xi Zhang; Ping Gao
Journal:  RSC Adv       Date:  2019-08-21       Impact factor: 4.036

2.  Efficacy of titanium brush, 915 nm diode laser, citric acid for eradication of Staphylococcus aureus from implant surfaces.

Authors:  Mohammad Reza Karimi; Behshad Farkhondemehr; Motahare Ghaeni Najafi; Ardavan Etemadi; Nasim Chiniforush
Journal:  BMC Oral Health       Date:  2021-12-07       Impact factor: 2.757

3.  Bone defect development in experimental canine peri-implantitis models: a systematic review.

Authors:  A Solderer; M de Boer; D B Wiedemeier; M Solderer; C C Liu; P R Schmidlin
Journal:  Syst Rev       Date:  2022-09-21
  3 in total