Literature DB >> 30471567

Development of cardiac troponin-I biosensor based on boron nitride quantum dots including molecularly imprinted polymer.

Mehmet Lütfi Yola1, Necip Atar2.   

Abstract

The cardiac Troponin-I (cTnI) is one of the subunits of cardiac troponin complexes and a pivotal biochemical marker of acute myocardial infarction (AMI). Due to its myocardial specificity, cTnI is widely used for the diagnosis of AMI diseases. In this study, a novel imprinted biosensor approach based on boron nitride quantum dots (BNQDs) was presented for cTnI detection in plasma samples. Various characterization methods such as scanning electron microscope (SEM), transmission electron microscope (TEM), x-ray diffraction (XRD), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used for all characterizations of nanomaterials. After the characterization analysis, cTnI imprinted electrode was developed in the presence of 100.0 mM pyrrole containing 25.0 mM cTnI. After that, the analytical studies of cTnI in plasma samples were performed by using cTnI imprinted biosensor. The results of the study have revealed that 0.01-5.00 ng mL-1 and 0.0005 ng mL-1 were found as the linearity range and the detection limit (LOD). Moreover, the selectivity of cTnI imprinted glassy carbon electrode (GCE) was investigated for plasma sample analysis in the presence of other nonspecific and specific proteins including cardiac myoglobin (MYG), bovine serum albumin (BSA) and cardiac troponin T (cTnT), respectively. Furthermore, the prepared biosensor was examined in terms of stability, repeatability, reproducibility and reusability. Finally, the imprinted biosensor was applied to the plasma samples having high recovery.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Boron nitride quantum dots; Cardiac Troponin-I; Molecular imprinted biosensor; Plasma

Mesh:

Substances:

Year:  2018        PMID: 30471567     DOI: 10.1016/j.bios.2018.11.016

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  13 in total

1.  Novel voltammetric tumor necrosis factor-alpha (TNF-α) immunosensor based on gold nanoparticles involved in thiol-functionalized multi-walled carbon nanotubes and bimetallic Ni/Cu-MOFs.

Authors:  Mehmet Lütfi Yola; Necip Atar
Journal:  Anal Bioanal Chem       Date:  2021-02-05       Impact factor: 4.142

2.  Electrochemical α-fetoprotein immunosensor based on Fe3O4NPs@covalent organic framework decorated gold nanoparticles and magnetic nanoparticles including SiO2@TiO2.

Authors:  Ömer Saltuk Bölükbaşi; Bahar Bankoğlu Yola; Ceren Karaman; Necip Atar; Mehmet Lütfi Yola
Journal:  Mikrochim Acta       Date:  2022-06-02       Impact factor: 5.833

3.  A molecularly imprinted electrochemical biosensor based on hierarchical Ti2Nb10O29 (TNO) for glucose detection.

Authors:  Ceren Karaman; Onur Karaman; Necip Atar; Mehmet Lütfi Yola
Journal:  Mikrochim Acta       Date:  2021-12-11       Impact factor: 5.833

4.  Electrochemical immuno determination of connective tissue growth factor levels on nitrogen-doped graphene.

Authors:  Jing Ma; Junhui Chen; YuanYuan Li; Xinru Zhang-Peng; Hong Wei; Wen Li; Fangdi Hu; Yan Zhang
Journal:  Mikrochim Acta       Date:  2022-04-09       Impact factor: 5.833

Review 5.  Recent advances in quantum dots-based biosensors for antibiotics detection.

Authors:  Rui Ding; Yue Chen; Qiusu Wang; Zhengzhang Wu; Xing Zhang; Bingzhi Li; Lei Lin
Journal:  J Pharm Anal       Date:  2021-08-04

Review 6.  Electroanalytical point-of-care detection of gold standard and emerging cardiac biomarkers for stratification and monitoring in intensive care medicine - a review.

Authors:  Robert D Crapnell; Nina C Dempsey; Evelyn Sigley; Ascanio Tridente; Craig E Banks
Journal:  Mikrochim Acta       Date:  2022-03-12       Impact factor: 6.408

Review 7.  Evaluation of Molecularly Imprinted Polymers for Point-of-Care Testing for Cardiovascular Disease.

Authors:  Brian Regan; Fiona Boyle; Richard O'Kennedy; David Collins
Journal:  Sensors (Basel)       Date:  2019-08-09       Impact factor: 3.576

8.  Ultra-Stable UiO-66 Involved Molecularly Imprinted Polymers for Specific and Sensitive Determination of Tyramine Based on Quartz Crystal Microbalance Technology.

Authors:  Chi-Xuan Yao; Ning Zhao; Jing-Min Liu; Guo-Zhen Fang; Shuo Wang
Journal:  Polymers (Basel)       Date:  2020-01-31       Impact factor: 4.329

Review 9.  Nanotechnology for cardiovascular diseases.

Authors:  Qinqin Hu; Zheyan Fang; Junbo Ge; Hua Li
Journal:  Innovation (Camb)       Date:  2022-02-02

10.  Sensitive sandwich-type voltammetric immunosensor for breast cancer biomarker HER2 detection based on gold nanoparticles decorated Cu-MOF and Cu2ZnSnS4 NPs/Pt/g-C3N4 composite.

Authors:  Mehmet Lütfi Yola
Journal:  Mikrochim Acta       Date:  2021-02-10       Impact factor: 5.833

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.