Literature DB >> 30469719

Multicascade-linked synthetic wavelength digital holography using an optical-comb-referenced frequency synthesizer.

Masatomo Yamagiwa, Takeo Minamikawa, Clément Trovato, Takayuki Ogawa, Dahi Ghareab Abdelsalam Ibrahim, Yusuke Kawahito, Ryo Oe, Kyuki Shibuya, Takahiko Mizuno, Emmanuel Abraham, Yasuhiro Mizutani, Tetsuo Iwata, Hirotsugu Yamamoto, Kaoru Minoshima, Takeshi Yasui.   

Abstract

Digital holography (DH) is a promising method for non-contact surface topography because the reconstructed phase image can visualize the nanometer unevenness in a sample. However, the axial range of this method is limited to the range of the optical wavelength due to the phase wrapping ambiguity. Although the use of two different wavelengths of light and the resulting synthetic wavelength, i.e., synthetic wavelength DH, can expand the axial range up to several hundreds of millimeters, its axial precision does not reach sub-micrometer. In this article, we constructed a tunable external cavity laser diode phase-locked to an optical frequency comb, namely, an optical-comb-referenced frequency synthesizer, enabling us to generate multiple synthetic wavelengths within the range of 32 µm to 1.20 m. A multiple cascade link of the phase images among an optical wavelength ( = 1.520 µm) and 5 different synthetic wavelengths ( = 32.39 µm, 99.98 µm, 400.0 µm, 1003 µm, and 4021 µm) enables the shape measurement of a reflective millimeter-sized stepped surface with the axial resolution of 34 nm. The axial dynamic range, defined as the ratio of the axial range ( = 2.0 mm) to the axial resolution ( = 34 nm), achieves 5.9 × 105, which is larger than that of previous synthetic wavelength DH. Such a wide axial dynamic range capability will further expand the application field of DH for large objects with meter dimensions.

Entities:  

Year:  2018        PMID: 30469719     DOI: 10.1364/OE.26.026292

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  2 in total

1.  Erythrocyte volumetric measurements in imaging flow cytometry using simultaneous three-wavelength digital holographic microscopy.

Authors:  Nir A Turko; Natan T Shaked
Journal:  Biomed Opt Express       Date:  2020-10-22       Impact factor: 3.732

2.  Deformation Wave Theory and Application to Optical Interferometry.

Authors:  Sanichiro Yoshida; Tomohiro Sasaki
Journal:  Materials (Basel)       Date:  2020-03-17       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.