Literature DB >> 304688

[A new method for calibration of electrophysiological recording systems (author's transl)].

I Wilmanns, R Stodtmeister.   

Abstract

The method described in this paper permits determination of amplification, band-pass properties, and electrode impedance in electrophysiological experimental setups. The battery powered test-signal generator drives square-wave current pulses through a 2 ohm resistance, which acts as a source of 100 muV p-p pulses. The 2 ohm resistor is wired in series with one of the electrode leads and remains there permanently. For calibration of the above-mentioned properties, one need only turn the generator on, without changing the measurement setup. By observing the shape of the square waves after passing through the system, it is possible to judge the band-pass characteristics of the entire system. Electrode impedance may be measured by putting a (variable) resistor in parallel with the preamplifier input. The test signal current is of the same order of magnitude as currents from biological signal sources. This method makes working with electrophysiological measurement systems which are used in electroretinography, electrooculography, and recording of visually-evoked cortical potentials in ophthalmology much easier.

Mesh:

Year:  1977        PMID: 304688     DOI: 10.1007/bf00413461

Source DB:  PubMed          Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol        ISSN: 0065-6100


  1 in total

1.  A TIME LOCKED, LOW LEVEL CALIBRATOR.

Authors:  J W EMDE
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1964-06
  1 in total
  6 in total

1.  IOP measurement and central corneal thickness.

Authors:  Richard Stodtmeister; Martina Kron; Wilhelm Gaus
Journal:  Br J Ophthalmol       Date:  2002-01       Impact factor: 4.638

2.  Changes of the current pathways in the eye due to coating agents during electroretinography.

Authors:  R Stodtmeister; I Wilmanns
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1978-06-19

3.  The influence of coating agents on the electrode circuit in electroretinography.

Authors:  R Stodtmeister; I Wilmanns
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1978-06-19

4.  Bandpass measurements in the electroretinographic electrode circuit.

Authors:  R Stodtmeister; I Wilmanns
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1978-11-30

5.  Autoregulation of ocular blood flow during changes in intraocular pressure. Preliminary results.

Authors:  L E Pillunat; R Stodtmeister; I Wilmanns; T Christ
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1985       Impact factor: 3.117

6.  Pressure compliance of the optic nerve head in low tension glaucoma.

Authors:  L E Pillunat; R Stodtmeister; I Wilmanns
Journal:  Br J Ophthalmol       Date:  1987-03       Impact factor: 4.638

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.