Literature DB >> 30467827

Fibreoptic-guided tracheal intubation through i-gel® and LMA® ProtectorTM supraglottic airway devices - a randomised comparison.

C Mendonca1, C C Tourville1, H Jefferson2, A Nowicka1, M Patteril1, V Athanassoglou2.   

Abstract

Fibreoptic-guided tracheal intubation using a supraglottic airway device as a conduit is a technique that can be used in anticipated and unanticipated difficult airway management. Although the i-gel® supraglottic airway device has been examined for this purpose, the LMA® ProtectorTM , a recently introduced second-generation supraglottic airway device, has not been evaluated for this use in clinical trials. This prospective, randomised clinical trial compared fibreoptic-guided tracheal intubation via i-gel and LMA Protector supraglottic airway devices in two UK hospitals. Patients who were ASA physical status 1 or 2 and undergoing elective surgery requiring tracheal intubation were recruited to the study. A block randomisation list was generated for each study site. The primary outcome measure was time to successful tracheal intubation and secondary outcomes were tracheal intubation success rate, glottic view through flexible fibrescope, ease of tracheal intubation using operator visual analogue score, supraglottic airway device insertion time and insertion success rate. Ninety patients were randomly allocated to each device, and final data analysis was carried out for 92 patients in the i-gel group and 86 patients in the LMA Protector group. Mean (SD) tracheal intubation time in the i-gel and LMA Protector groups were 54.3 (13.8) s and 52.0 (13.0) s, respectively (p = 0.240). There were no significant differences in tracheal intubation success rate, glottic view and ease of tracheal intubation between the two groups. This study demonstrates that the LMA Protector supraglottic airway device is comparable to the i-gel supraglottic airway device as a conduit for fibreoptic-guided tracheal intubation.
© 2018 Association of Anaesthetists.

Entities:  

Keywords:  airway management; failed tracheal intubation; fibreoptic tracheal intubation; supraglottic airway

Mesh:

Year:  2018        PMID: 30467827     DOI: 10.1111/anae.14475

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  3 in total

1.  Supraglottic airway devices: more good than bad.

Authors:  Hee-Pyoung Park
Journal:  Korean J Anesthesiol       Date:  2019-11-29

Review 2.  Optical Devices in Tracheal Intubation-State of the Art in 2020.

Authors:  Jan Matek; Frantisek Kolek; Olga Klementova; Pavel Michalek; Tomas Vymazal
Journal:  Diagnostics (Basel)       Date:  2021-03-22

3.  Comparison of SaCoVLM™ video laryngeal mask-guided intubation and i-gel combined with flexible bronchoscopy-guided intubation in airway management during general anesthesia: a non-inferiority study.

Authors:  Chun-Ling Yan; Yi-Qi-Yuan Zhang; Ying Chen; Zong-Yang Qv; Ming-Zhang Zuo
Journal:  BMC Anesthesiol       Date:  2022-09-22       Impact factor: 2.376

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.