Literature DB >> 30467023

The value of postoperative prosthesis alignment and patellar height measurements on standard X-rays after Total Knee Arthroplasty: Does it relate to knee function after 5 years?

Rachid Rassir1, Fabian van de Bunt2, Inger N Sierevelt2, Peter A Nolte2.   

Abstract

BACKGROUND: The purpose of this retrospective cohort study was to investigate the influence of parameters of malalignment on knee function 5 years post TKA and, additionally, to explore alterations in patellar height after TKA.
METHODS: All 661 patients undergoing TKA between 2010 and 2011 were considered for inclusion. Preoperative and 1-year postoperative short-leg radiographs were assessed for malalignment parameters: coronal tibial angle (cTA), sagittal tibial angle (sTA), femoral flexion angle (FFA) and mediolateral tibial mismatch. Patellar height was measured using the modified Insall-Salvati ratio. We determined improvements in knee function utilizing the Knee Society Score (Function score, KSS-F), Oxford Knee Score (OKS) and Algofunctional index (AI). Influences of malalignment parameters were analyzed univariate and selected (p < 0.10) for multivariate linear regression analysis. Inter-observer reproducibility was assessed by test-retest analysis of 30 randomly selected radiographs and calculation of an intra-class correlation coefficient (ICC) for all radiographic parameters.
RESULTS: Three-hundred and four patients were included. Multivariate regression showed degrees of cTA malalignment to be significantly associated with only the KSS-F (β = -3.52). Correction of coronal deformity was stronger associated with knee function (KSS-F β = 2.81; AI β = -0.36). Patellar height was significantly reduced after TKA (1.51 vs 1.44). Decrease of patellar height was weakly associated with the OKS (β = 10.69). ICC scores were: cTA 0.81, sTA 0.57, IS 0.72, FFA 0.75.
CONCLUSION: Postoperative coronal tibial plate alignment and correction of preoperative coronal deformity are associated with improved knee function 5 years post TKA. Decrease in patellar height was weakly associated with knee function. Short-leg radiography can be a sufficient screening tool for prosthesis alignment.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Alignment; Patellar height; Placement; Total Knee Arthroplasty; X-ray

Mesh:

Year:  2018        PMID: 30467023     DOI: 10.1016/j.knee.2018.09.014

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  4 in total

Review 1.  Current evidence base for kinematic alignment.

Authors:  L-R Tuecking; P Savov; H Windhagen; M Ettinger
Journal:  Orthopade       Date:  2020-07       Impact factor: 1.087

2.  Patellar height after unicompartmental knee arthroplasty: comparison between fixed and mobile bearing.

Authors:  Riccardo D'Ambrosi; Matteo Buda; Alessandro Nuara; Ilaria Mariani; Michele Scelsi; Federico Valli; Nicola Ursino; Michael Tobias Hirschmann
Journal:  Arch Orthop Trauma Surg       Date:  2021-10-20       Impact factor: 2.928

3.  Tibial component coverage affects tibial bone resorption and patient-reported outcome measures for patients following total knee arthroplasty.

Authors:  Changquan Liu; Guanglei Zhao; Kangming Chen; Jinyang Lyu; Jie Chen; Jingsheng Shi; Gangyong Huang; Feiyan Chen; Yibing Wei; Siqun Wang; Jun Xia
Journal:  J Orthop Surg Res       Date:  2021-02-12       Impact factor: 2.359

Review 4.  A Protocol to Systematic Radiographic Assessment of Primary Total Knee Arthroplasty.

Authors:  Ahmed A Khalifa; Arun B Mullaji; Alaa M Mostafa; Osama A Farouk
Journal:  Orthop Res Rev       Date:  2021-07-17
  4 in total