Literature DB >> 30465549

Integrating a low-field open MR scanner with a static proton research beam line: proof of concept.

Sonja M Schellhammer1, Aswin L Hoffmann, Sebastian Gantz, Julien Smeets, Erik van der Kraaij, Sébastien Quets, Stefan Pieck, Leonhard Karsch, Jörg Pawelke.   

Abstract

On-line image guidance using magnetic resonance (MR) imaging is expected to improve the targeting accuracy of proton therapy. However, to date no combined system exists. In this study, for the first time a low-field open MR scanner was integrated with a static proton research beam line to test the feasibility of simultaneous irradiation and imaging. The field-of-view of the MR scanner was aligned with the beam by taking into account the Lorentz force induced beam deflection. Various imaging sequences for extremities were performed on a healthy volunteer and on a patient with a soft-tissue sarcoma of the upper arm, both with the proton beam line switched off. T 1-weighted spin echo images of a tissue-mimicking phantom were acquired without beam, with energised beam line magnets and during proton irradiation. Beam profiles were acquired for the MR scanner's static magnetic field alone and in combination with the dynamic gradient fields during the acquisition of different imaging sequences. It was shown that MR imaging is feasible in the electromagnetically contaminated environment of a proton therapy facility. The observed quality of the anatomical MR images was rated to be sufficient for target volume definition and positioning. The tissue-mimicking phantom showed no visible beam-induced image degradation. The beam profiles depicted no influence due to the dynamic gradient fields of the imaging sequences. This study proves that simultaneous irradiation and in-beam MR imaging is technically feasible with a low-field MR scanner integrated with a static proton research beam line.

Entities:  

Mesh:

Year:  2018        PMID: 30465549     DOI: 10.1088/1361-6560/aaece8

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

Review 1.  Integrated MRI-guided radiotherapy - opportunities and challenges.

Authors:  Paul J Keall; Caterina Brighi; Carri Glide-Hurst; Gary Liney; Paul Z Y Liu; Suzanne Lydiard; Chiara Paganelli; Trang Pham; Shanshan Shan; Alison C Tree; Uulke A van der Heide; David E J Waddington; Brendan Whelan
Journal:  Nat Rev Clin Oncol       Date:  2022-04-19       Impact factor: 65.011

2.  Dosimetric evaluation of synthetic CT generated with GANs for MRI-only proton therapy treatment planning of brain tumors.

Authors:  Samaneh Kazemifar; Ana M Barragán Montero; Kevin Souris; Sara T Rivas; Robert Timmerman; Yang K Park; Steve Jiang; Xavier Geets; Edmond Sterpin; Amir Owrangi
Journal:  J Appl Clin Med Phys       Date:  2020-03-26       Impact factor: 2.102

Review 3.  MR-guided proton therapy: a review and a preview.

Authors:  Aswin Hoffmann; Bradley Oborn; Maryam Moteabbed; Susu Yan; Thomas Bortfeld; Antje Knopf; Herman Fuchs; Dietmar Georg; Joao Seco; Maria Francesca Spadea; Oliver Jäkel; Christopher Kurz; Katia Parodi
Journal:  Radiat Oncol       Date:  2020-05-29       Impact factor: 3.481

4.  Technical Note: Design and commissioning of a water phantom for proton dosimetry in magnetic fields.

Authors:  Hermann Fuchs; Fatima Padilla-Cabal; Andreas Hummel; Dietmar Georg
Journal:  Med Phys       Date:  2020-12-08       Impact factor: 4.071

Review 5.  Management of Motion and Anatomical Variations in Charged Particle Therapy: Past, Present, and Into the Future.

Authors:  Julia M Pakela; Antje Knopf; Lei Dong; Antoni Rucinski; Wei Zou
Journal:  Front Oncol       Date:  2022-03-09       Impact factor: 6.244

Review 6.  Accelerators, Gantries, Magnets and Imaging Systems for Particle Beam Therapy: Recent Status and Prospects for Improvement.

Authors:  Edward W Collings; Lanchun Lu; Nilendu Gupta; Mike D Sumption
Journal:  Front Oncol       Date:  2022-02-15       Impact factor: 6.244

Review 7.  Roadmap: proton therapy physics and biology.

Authors:  Harald Paganetti; Chris Beltran; Stefan Both; Lei Dong; Jacob Flanz; Keith Furutani; Clemens Grassberger; David R Grosshans; Antje-Christin Knopf; Johannes A Langendijk; Hakan Nystrom; Katia Parodi; Bas W Raaymakers; Christian Richter; Gabriel O Sawakuchi; Marco Schippers; Simona F Shaitelman; B K Kevin Teo; Jan Unkelbach; Patrick Wohlfahrt; Tony Lomax
Journal:  Phys Med Biol       Date:  2021-02-26       Impact factor: 4.174

8.  Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields.

Authors:  Fatima Padilla-Cabal; Jose Alejandro Fragoso; Andreas Franz Resch; Dietmar Georg; Hermann Fuchs
Journal:  Med Phys       Date:  2019-11-13       Impact factor: 4.071

Review 9.  Future Developments in Charged Particle Therapy: Improving Beam Delivery for Efficiency and Efficacy.

Authors:  Jacinta Yap; Andrea De Franco; Suzie Sheehy
Journal:  Front Oncol       Date:  2021-12-09       Impact factor: 5.738

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.