Literature DB >> 30464922

"Hanger" in Intubation and Laryngoscopy.

Devkumar Rengaraja1, Mohan Jagade1, Radhika Sonate1, Karthik Rao1, Deoshri Ramtek1.   

Abstract

Achieving an adequate exposure in laryngoscopy is an extremely tedious task for the operating surgeon, especially for the anterior commissure lesions. Various maneuvers have been described to overcome this difficulty, but failed in providing an adequate exposure leading to a poor outcome. To create a device that can deliver uniform pressure over the laryngeal cartilage and succeed in providing an adequate exposure of the glottic lesion. A total of 44 patients were included in the study, divided into two groups containing 22 patients each. The distance at the level of anterior commissure from the superior border of the distal end of the laryngoscope was noted and compared. Group A subjected to digital cricoid pressure showed a mean distance of 9.09 of exposure with variance of 1.22 and Group B subjected to cricoid pressure with the cricoid catapult showed a mean distance of 11.76 with variance of 1.59. The groups were statistically analyzed using Anova Test and the test was found to be very significant (p < 0.0001). The catapult is made of a hanger defining its economics, which has a vital role in difficult intubations especially in anterior placed larynx, short neck and obese patients, also succeeds in providing an adequate exposure of the glottic lesion, (especially the anterior commissure) by delivering uniform pressure over the laryngeal cartilage, leading to a superior operative outcome.

Entities:  

Keywords:  Anterior commissure; Catapult; Cricoid pressure; Intubation

Year:  2018        PMID: 30464922      PMCID: PMC6224829          DOI: 10.1007/s12070-018-1330-7

Source DB:  PubMed          Journal:  Indian J Otolaryngol Head Neck Surg        ISSN: 2231-3796


  11 in total

1.  Regurgitation and oesophageal rupture with cricoid pressure: a cadaver study.

Authors:  R G Vanner; B J Pryle
Journal:  Anaesthesia       Date:  1992-09       Impact factor: 6.955

2.  Cricoid pressure to control regurgitation of stomach contents during induction of anaesthesia.

Authors:  B A SELLICK
Journal:  Lancet       Date:  1961-08-19       Impact factor: 79.321

3.  Carcinoma of the anterior commissure of the larynx: II. Proposal of a new staging system.

Authors:  L Rucci; L Gammarota; O Gallo
Journal:  Ann Otol Rhinol Laryngol       Date:  1996-05       Impact factor: 1.547

4.  The effect of single-handed cricoid pressure on neck movement after applying manual in-line stabilisation.

Authors:  D A Gabbott
Journal:  Anaesthesia       Date:  1997-06       Impact factor: 6.955

5.  Rupture of the oesophagus during cricoid pressure.

Authors:  S J Ralph; C A Wareham
Journal:  Anaesthesia       Date:  1991-01       Impact factor: 6.955

6.  Improved suspension laryngoscope for use with operative microscope.

Authors:  J H Woodrow
Journal:  Trans Am Acad Ophthalmol Otolaryngol       Date:  1971 Mar-Apr

7.  [Alfred Kirstein (1863-1922)--pioneer in direct laryngoscopy].

Authors:  M Reinhard; E Eberhardt
Journal:  Anasthesiol Intensivmed Notfallmed Schmerzther       Date:  1995-06       Impact factor: 0.698

8.  Endoscopic management of early supraglottic cancer.

Authors:  S M Zeitels; C W Vaughan; G F Domanowski
Journal:  Ann Otol Rhinol Laryngol       Date:  1990-12       Impact factor: 1.547

9.  Global cancer statistics, 2002.

Authors:  D Max Parkin; Freddie Bray; J Ferlay; Paola Pisani
Journal:  CA Cancer J Clin       Date:  2005 Mar-Apr       Impact factor: 508.702

Review 10.  Systematic direct laryngoscopy: the Lindholm laryngoscopes.

Authors:  Bruce Benjamin; Carl-Eric Lindholm
Journal:  Ann Otol Rhinol Laryngol       Date:  2003-09       Impact factor: 1.547

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.