| Literature DB >> 30464384 |
Tomofusa Yamauchi1, Hitoshi Tabuchi1, Kosuke Takase1, Zaigen Ohara1, Hitoshi Imamura1, Yoshiaki Kiuchi2.
Abstract
AIM: We compared the visual performance of toric intraocular lenses (IOLs) and non-toric IOLs made of the same material. PATIENTS AND MATERIALS: The subjects included patients implanted with either Acrysof IQ® toric IOLs (SN6AT3-9) or Acrysof IQ® IOLs (SN60WF) bilaterally. The toric group included 103 patients who were implanted with Acrysof IQ toric IOLs bilaterally. The non-toric group was a corneal astigmatism-matched control group and included 103 patients who were implanted with Acrysof IQ IOLs bilaterally.Entities:
Keywords: astigmatism; cataract; cataract surgery; visual function
Year: 2018 PMID: 30464384 PMCID: PMC6219313 DOI: 10.2147/OPTH.S183899
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Summary of both the groups
| Toric | Non-toric | ||
|---|---|---|---|
|
| |||
| IOL | SN6AT3-9 | SN60WF | |
| n | 103 | 103 | |
| Age (years) | 72.25 (6.78) | 73.69 (7.18) | 0.1411 |
| Preoperative corneal astigmatism (D) | 1.133 (0.444) | 1.127 (0.41) | 0.9181 |
| Postoperative spherical equivalent (D) | 0.089 (0.492) | −0.015 (0.525) | 0.1433 |
| Postoperative subjective astigmatism (D) | 0.84 (0.442) | 1.42 (0.698) | <0.0001 |
| Axis of postoperative subjective astigmatism | WTR: 14 | WTR: 17 | 0.8996 |
| Obl: 15 | Obl: 10 | ||
| ATR: 54 | ATR: 69 | ||
| None: 20 | None: 7 | ||
Notes:
Mean (SD).
P-value by Student’s t-test (two sided).
Astigmatism of right eyes.
P-value by Mann–Whitney U test (two sided).
Number of subjects. None: subjects with cylinder power <0.5 D.
P-value by chi-squared test (WTR/ATR ratio).
Abbreviations: ATR, against the rule astigmatism; IOL, intraocular lens; Obl, oblique astigmatism; WTR, with the rule astigmatism.
Figure 1Uncorrected and corrected VA of the toric and non-toric groups (mean±SD).
Notes: The P-values were determined using the Mann–Whitney U test. **P<0.01.
Abbreviations: CDVA, corrected distant VA; LogMAR, logarithm of the minimum angle of resolution; UDVA, uncorrected distant VA; VA, visual acuity.
Figure 2Cumulative UDVA, toric group vs non-toric group.
Abbreviation: UDVA, uncorrected distant visual acuity.
Contrast sensitivity without/with glare
| Optotype size | Toric | Non-toric | |
|---|---|---|---|
|
| |||
|
| |||
| 7 | 0.318 (0.119) | 0.333 (0.122) | 0.2521 |
| 10 | 0.163 (0.108) | 0.168 (0.107) | 0.4351 |
| 16 | 0.085 (0.073) | 0.085 (0.056) | 0.2670 |
| 25 | 0.049 (0.037) | 0.050 (0.030) | 0.4235 |
| 40 | 0.038 (0.028) | 0.038 (0.022) | 0.6695 |
| 63 | 0.033 (0.028) | 0.028 (0.013) | 0.1943 |
|
| |||
|
| |||
| 7 | 0.385 (0.105) | 0.397 (0.102) | 0.3767 |
| 10 | 0.235 (0.125) | 0.244 (0.131) | 0.6461 |
| 16 | 0.133 (0.102) | 0.136 (0.105) | 0.8074 |
| 25 | 0.086 (0.072) | 0.089 (0.079) | 0.9308 |
| 40 | 0.061 (0.042) | 0.064 (0.049) | 0.3366 |
| 63 | 0.052 (0.037) | 0.044 (0.027) | 0.1614 |
Notes: Mean (SD).
P-value by Mann–Whitney U test (two-sided).
Postoperative spectacle dependency
| Never (n) | Occasionally (n) | Always (n) | Spectacle dependency (%) | ||
|---|---|---|---|---|---|
|
| |||||
| Distance | 0.0003 | ||||
| Toric | 83 | 9 | 11 | 19.4 | |
| Non-toric | 35 | 7 | 61 | 66.0 | |
| Near | 0.3514 | ||||
| Toric | 12 | 23 | 68 | 88.3 | |
| Non-toric | 14 | 15 | 74 | 86.4 | |
Note: The P-values were determined using the chi-squared test.
Postoperative scores of the NEI VFQ-25
| Toric | Non-toric | ||
|---|---|---|---|
|
| |||
| Composite | 89.9 (0.6) | 89.9 (0.8) | |
| General health | 60.7 (1.6) | 60.9 (1.6) | |
| General vision | 79.6 (1.1) | 78.4 (1.3) | |
| Ocular pain | 88.9 (1.5) | 90.5 (1.4) | |
| Near vision | 90.5 (1.2) | 92.0 (1.5) | |
| Distance vision | 93.2 (1.0) | 92.6 (1.1) | |
| Social function | 95.6 (0.8) | 95.6 (0.9) | |
| Mental health | 94.8 (0.9) | 94.9 (1.3) | |
| Role limitation | 95.9 (0.7) | 95.7 (1.0) | |
| Dependency | 98.0 (0.6) | 97.9 (0.7) | |
| Driving | 91.1 (1.5) | 90.4 (1.5) | |
| Color vision | 96.8 (0.9) | 97.3 (0.9) | |
| Peripheral vision | 94.2 (1.2) | 92.7 (1.5) | |
Notes: The shown values represent the mean (SD) of 103 patients in each group, except for the questions regarding driving and color vision. For the question on driving, the value was derived from the responses of 58 patients in the toric group and 64 patients in the non-toric group. For the question on color vision, the value was derived from the responses of 102 patients in the toric group and 100 patients in the non-toric group. The P-values were determined using Mann–Whitney U test (two sided).
Abbreviation: NEI VFQ-25, 25-item National Eye Institute Visual Function Questionnaire.