Turbuhaler: a new device for dry powder terbutaline inhalation.

C R Johnsen1, E R Weeke.   

Abstract

The aim of this study was to compare bronchodilator response and adverse effects of terbutaline when administered with the metered dose inhaler (MDI) Bricanyl and with the dry powder inhaler Bricanyl Turbuhaler (BT). Nine adult patients with bronchial asthma participated. The study was of an open crossover design. At 30-min intervals the patients inhaled increasing doses of terbutaline (0.25 mg to 5.0 mg cumulated) from either the conventional MDI or from the BT. After each inhalation FEV1, FVC, heart rate, muscle tremor and adverse effects were recorded. Both treatments, BT and MDI, resulted in a dose-related increase in lung function, without any statistical difference. Taste sensation, muscle tremor and increase in heart rate were observed in both groups. Because of the design of the BT one may assume that inhalation failure can be avoided.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3046409     DOI: 10.1111/j.1398-9995.1988.tb00434.x

Source DB:  PubMed          Journal:  Allergy        ISSN: 0105-4538            Impact factor:   13.146


  5 in total

1.  Systematic review of clinical effectiveness of pressurised metered dose inhalers versus other hand held inhaler devices for delivering beta (2 )agonists bronchodilators in asthma.

Authors:  F S Ram; J Wright; D Brocklebank; J E White
Journal:  BMJ       Date:  2001-10-20

2.  Effects, side effects and plasma concentrations of terbutaline in adult asthmatics after inhaling from a dry powder inhaler device at different inhalation flows and volumes.

Authors:  T Engel; B Scharling; B Skovsted; J H Heinig
Journal:  Br J Clin Pharmacol       Date:  1992-04       Impact factor: 4.335

Review 3.  Review of therapeutically equivalent alternatives to short acting beta(2) adrenoceptor agonists delivered via chlorofluorocarbon-containing inhalers.

Authors:  D A Hughes; A Woodcock; T Walley
Journal:  Thorax       Date:  1999-12       Impact factor: 9.139

4.  Importance of the inhalation device on the effect of budesonide.

Authors:  L Agertoft; S Pedersen
Journal:  Arch Dis Child       Date:  1993-07       Impact factor: 3.791

5.  Comparative efficacy of terbutaline sulphate delivered by Turbuhaler dry powder inhaler or pressurised metered dose inhaler with Nebuhaler spacer in children during an acute asthmatic episode.

Authors:  S Drblik; G Lapierre; R Thivierge; J Turgeon; P Gaudreault; B Cummins-McManus; I Verdy; J Haddon; J Lee; S Spier
Journal:  Arch Dis Child       Date:  2003-04       Impact factor: 3.791

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.