Literature DB >> 30461075

Optimal axis for lumbosacral interbody fusion: Prospective finite element analysis and retrospective 3D-CT measurement.

Yang Li1,2, Dengwei He3, Nuo Chen2, Ting Lv2, Aimin Wu4, Zhongke Lin4, Zihai Ding1, Zhengguo Wang5, Lijun Wu2.   

Abstract

A feasible and optimal axis of biomechanical and anatomic significance in axial lumbosacral interbody fusion (AxiaLIF) was designed. Using the image dataset of an adult volunteer, two groups of finite element (FE) models of the AxiaLIF, lumbosacral anterior column fixation (ACF) models and middle column fixation (MCF) models with different bone graft fusion degrees, were prospectively established, and their biomechanical differences were comparatively predicted. In addition, 3D reconstruction was performed by retrospectively collecting CT data from pelvises in 60 adult cases. Their anatomic parameters relating to two groups of models were digitally measured and statistically compared. Numerical analysis revealed that the load and the maximum stress on the screw as well as the maximum stress difference between the screw and peripheral tissues in the MCF model were reduced compared with the ACF model. These indices of both models all decreased markedly in response to the increase in the disc fusion degree. Statistical analysis revealed that the effective fixed length of the sacrum in the MCF model was increased compared with the ACF model (P < 0.05). The surgical dissection distance of presacral vessels and nerves from the axis to sacrum of the MCF model was reduced compared with the ACF model (P < 0.05). The feasible and optimal axis of biomechanical and anatomic significance of the AxiaLIF is similar to the axis of the MCF model. Disc bone graft fusions plus axial screw fixations of middle column could strengthen the biomechanical stability of the AxiaLIF model. Clin. Anat. 32:337-347, 2019.
© 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

Entities:  

Keywords:  3D-CT; axial lumbosacral interbody fusion (AxiaLIF); biomechanics; digital anatomy; finite element (FE) analysis

Mesh:

Year:  2018        PMID: 30461075     DOI: 10.1002/ca.23316

Source DB:  PubMed          Journal:  Clin Anat        ISSN: 0897-3806            Impact factor:   2.414


  1 in total

1.  S2-alar-iliac screw and S1 pedicle screw fixation for the treatment of non-osteoporotic sacral fractures: a finite element study.

Authors:  Jianxiong Zheng; Xiaoreng Feng; Jie Xiang; Fei Liu; Frankie K L Leung; Bin Chen
Journal:  J Orthop Surg Res       Date:  2021-10-30       Impact factor: 2.359

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.