Mechanical properties of a new thermally deformable mitral valve annuloplasty ring and its effects on the mitral valve.

Tatsuya Seki1, Katsuyoshi Jimuro2, Yasushige Shingu3, Satoru Wakasa1, Hiroki Katoh4, Tomonori Ooka1, Tsuyoshi Tachibana1, Suguru Kubota1, Toshiro Ohashi5, Yoshiro Matsui6.   

Abstract

Ideally, an annuloplasty ring's shape should be changed intraoperatively if mitral valve repair is unsuccessful because of a short coaptation length or systolic anterior motion. Several post-implantation adjustable rings have been developed, but they are not freely deformable and are unsuitable for asymmetric repair of the valvular annulus. We developed a novel thermally deformable mitral annuloplasty ring to address these problems and assessed the ring's mechanical properties and its effect on the mitral valve anatomy. This ring was made of polycaprolactone. Tensile and bending tests were performed to evaluate the ring's mechanical properties. The ratio of the transverse and septal-lateral length was determined as 4:3. Using 10 pig hearts, we measured the post-deformation coaptation length and minimum distance from the coaptation to the ventricular septum, which is a factor of abnormal systolic anterior motion of the mitral valve. In the mechanical tests, the ring's yield point was greater than the deformation force of the annulus in humans. In pigs with deformation from "4:3" to "4:2", the coaptation length was significantly increased in each mitral valve part. In pigs with deformation from "4:3" to "4:4", the minimum distance from the coaptation to the ventricular septum was significantly increased. Asymmetrical ring deformation increased the coaptation length only at the deformed area. In conclusion, this new thermally deformable mitral annuloplasty ring could be "order-made" to effectively change the coaptation length in all parts of the mitral valve and the distance from the coaptation to septum post-deformation via intraoperative heating.

Entities:  

Keywords:  Mitral valve; Mitral valve annuloplasty ring; Polycaprolactone

Mesh:

Year:  2018        PMID: 30456661     DOI: 10.1007/s10047-018-1084-8

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  26 in total

1.  Three-dimensional echocardiographic assessment of annular shape changes in the normal and regurgitant mitral valve.

Authors:  S R Kaplan; G Bashein; F H Sheehan; M E Legget; B Munt; X N Li; M Sivarajan; E L Bolson; M Zeppa; M Z Arch; R W Martin
Journal:  Am Heart J       Date:  2000-03       Impact factor: 4.749

2.  A general method for estimating deformation and forces imposed in vivo on bioprosthetic heart valves with flexible annuli: in vitro and animal validation studies.

Authors:  R Shandas; M Mitchell; C Conrad; O Knudson; J Sorrell; S Mahalingam; M Fragoso; L Valdes-Cruz
Journal:  J Heart Valve Dis       Date:  2001-07

3.  Effects of fibre reinforcement on the mechanical properties of brushite cement.

Authors:  N J S Gorst; Y Perrie; U Gbureck; A L Hutton; M P Hofmann; L M Grover; J E Barralet
Journal:  Acta Biomater       Date:  2005-10-25       Impact factor: 8.947

4.  Echocardiographic predictors of left ventricular outflow tract obstruction and systolic anterior motion of the mitral valve after mitral valve reconstruction for myxomatous valve disease.

Authors:  A D Maslow; M M Regan; J M Haering; R G Johnson; R A Levine
Journal:  J Am Coll Cardiol       Date:  1999-12       Impact factor: 24.094

5.  Septal-lateral annular cinching abolishes acute ischemic mitral regurgitation.

Authors:  Tomasz A Timek; David T Lai; Frederick Tibayan; David Liang; George T Daughters; Paul Dagum; Neil B Ingels; D Craig Miller
Journal:  J Thorac Cardiovasc Surg       Date:  2002-05       Impact factor: 5.209

6.  Dynamic balance of the aortomitral junction.

Authors:  Emmanuel Lansac; Khee Hiang Lim; Yu Shomura; Wolfgang A Goetz; Hou Sen Lim; Nolan T Rice; Hashim Saber; Carlos M G Duran
Journal:  J Thorac Cardiovasc Surg       Date:  2002-05       Impact factor: 5.209

7.  Large annuloplasty rings facilitate mitral valve repair in Barlow's disease.

Authors:  David H Adams; Ani C Anyanwu; Parwis B Rahmanian; Vivian Abascal; Sacha P Salzberg; Farzan Filsoufi
Journal:  Ann Thorac Surg       Date:  2006-12       Impact factor: 4.330

8.  Characterization of polymeric poly(epsilon-caprolactone) injectable implant delivery system for the controlled delivery of contraceptive steroids.

Authors:  Magharla Dasaratha Dhanaraju; Damodaran Gopinath; Mohamed Rafiuddin Ahmed; Rajadas Jayakumar; Chandrasekar Vamsadhara
Journal:  J Biomed Mater Res A       Date:  2006-01       Impact factor: 4.396

9.  Does septal-lateral annular cinching work for chronic ischemic mitral regurgitation?

Authors:  Frederick A Tibayan; Filiberto Rodriguez; Frank Langer; Mary K Zasio; Lynn Bailey; David Liang; George T Daughters; Neil B Ingels; D Craig Miller
Journal:  J Thorac Cardiovasc Surg       Date:  2004-03       Impact factor: 5.209

Review 10.  Poly-epsilon-caprolactone microspheres and nanospheres: an overview.

Authors:  V R Sinha; K Bansal; R Kaushik; R Kumria; A Trehan
Journal:  Int J Pharm       Date:  2004-06-18       Impact factor: 5.875

View more
  1 in total

Review 1.  Journal of Artificial Organs 2019: the year in review : Journal of Artificial Organs Editorial Committee.

Authors:  Y Sawa; G Matsumiya; S Miyagawa; E Tatsumi; T Abe; K Fukunaga; S Ichiba; T Taguchi; K Kokubo; T Masuzawa; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; T Tsukiya; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2020-02-19       Impact factor: 1.731

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.