Literature DB >> 30453379

19 G nitinol needle versus 22 G needle for transduodenal endoscopic ultrasound-guided sampling of pancreatic solid masses: a randomized study.

Arthur Laquière1, Christine Lefort2, Frédérique Maire3, Alain Aubert4, Rodica Gincul5, Frédéric Prat6, Philippe Grandval7, Olivier Croizet8, James Boulant9, Geoffroy Vanbiervliet10, Guillaume Pénaranda11, Laurence Lecomte1, Bertrand Napoléon2, Christian Boustière1.   

Abstract

BACKGROUND: The aim of this prospective multicenter study was to compare a flexible 19 G needle with nitinol shaft (19 G Flex) with a standard 22 G needle for transduodenal endoscopic ultrasound (EUS)-guided sampling of pancreatic head tumors.
METHODS: Patients with pancreatic head tumors requiring tissue diagnosis were randomized into two arms: puncture with either a 19 G Flex needle or a 22 G needle. The primary end point was diagnostic accuracy for malignancy. The secondary end points were ergonomic scores, sample cytohistological quality, and complications. A 6-month follow-up was performed.
RESULTS: 125 patients were randomized and 122 were analyzed: 59 patients in the 19 G Flex arm and 63 patients in the 22 G arm. The final diagnosis was malignancy in 111 patients and benign condition in 11. In intention-to-treat analysis, the diagnostic accuracy for malignancy of the 19 G Flex and 22 G needles was 69.5 % (95 % confidence interval [CI] 56.1 % - 80.8 %) vs. 87.3 % (95 %CI 76.5 % - 94.4 %), respectively (P = 0.02). In per-protocol analysis excluding eight technical failures in the 19 G Flex group, the diagnostic accuracy of the 19 G Flex and 22 G needles was not statistically different: 80.4 % (95 %CI 66.9 % - 90.2 %) vs. 87.3 % (95 %CI 76.5 % - 94.4 %; P = 0.12). Technical success was higher in the 22 G arm than in the 19 G Flex arm: 100 % (95 %CI 94.3 % - 100 %) vs. 86.4 % (95 %CI 75.0 % - 94.0 %), respectively (P = 0.003). Transduodenal EUS-guided sampling was more difficult with the 19 G Flex (odds ratio 0.68, 95 %CI 0.47 - 0.97). CONCLUSION : The 19 G Flex needle was inferior to a standard 22 G needle in diagnosing pancreatic head cancer and more difficult to use in the transduodenal approach. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30453379     DOI: 10.1055/a-0757-7714

Source DB:  PubMed          Journal:  Endoscopy        ISSN: 0013-726X            Impact factor:   10.093


  5 in total

1.  Cumulative sum learning curves guiding multicenter multidisciplinary quality improvement of EUS-guided tissue acquisition of solid pancreatic lesions.

Authors:  Hannah M Schutz; Rutger Quispel; Bart J Veldt; Frank M M Smedts; Marie-Paule G F Anten; Klaas J Hoogduin; Pieter Honkoop; Francien H van Nederveen; Lieke Hol; Mike Kliffen; Claire E Fitzpatrick; Nicole S Erler; Marco J Bruno; Lydi M J W van Driel
Journal:  Endosc Int Open       Date:  2022-04-14

Review 2.  Therapeutic EUS: New tools, new devices, new applications.

Authors:  Barbara Braden; Vipin Gupta; Christoph Frank Dietrich
Journal:  Endosc Ultrasound       Date:  2019 Nov-Dec       Impact factor: 5.628

3.  Feasibility and Accuracy of Transduodenal Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Solid Lesions Using a 19-Gauge Flexible Needle: A Multicenter Study.

Authors:  Germana de Nucci; Maria Chiara Petrone; Nicola Imperatore; Edoardo Forti; Roberto Grassia; Silvia Giovanelli; Laura Ottaviani; Vincenzo Mirante; Giuseppe Sabatino; Carlo Fabbri; Mauro Manno; Paolo Giorgio Arcidiacono; Gianpiero Manes
Journal:  Clin Endosc       Date:  2020-05-25

4.  Comparative diagnostic accuracy of EUS needles in solid pancreatic masses: a network meta-analysis.

Authors:  Samuel Han; Furqan Bhullar; Omar Alaber; Ayesha Kamal; Puanani Hopson; Kavin Kanthasamy; Sarah Coughlin; Livia Archibugi; Nikhil Thiruvengadam; Christopher Moreau; David Jin; Pedram Paragomi; Francisco Valverde-López; Sajan Nagpal; Cemal Yazici; Georgios Papchristou; Peter J Lee; Venkata Akshintala
Journal:  Endosc Int Open       Date:  2021-05-27

Review 5.  The Utility of Endoscopic-Ultrasonography-Guided Tissue Acquisition for Solid Pancreatic Lesions.

Authors:  Hiroki Tanaka; Shimpei Matsusaki
Journal:  Diagnostics (Basel)       Date:  2022-03-19
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.