| Literature DB >> 3045322 |
M Beigbeder1, D Chappard, C Alexandre, L Vico, S Palle, G Riffat.
Abstract
Quantitative histological methods have proved to be the most effective methods in bone disease research. Faster and more accurate techniques are currently needed. We have developed a simple digitized image analysis system which allows accurate measurements of trabecular bone mass. The algorithm is based on the 'four-connected sets' mathematical theory. Given a numerized image displayed by a CCD camera, the algorithm recognizes all possible four-connected sets and provides area measurements. The first procedure automatically eliminates small, irrelevant profiles (wrinkles, cell nuclei, etc.) while larger profiles are erased interactively. The second procedure similarly erases the artefactual defects within the trabeculae (artefactual cracks or empty osteocytic lacunae). The method was shown to be very accurate and time-saving.Entities:
Mesh:
Year: 1988 PMID: 3045322 DOI: 10.1111/j.1365-2818.1988.tb04605.x
Source DB: PubMed Journal: J Microsc ISSN: 0022-2720 Impact factor: 1.758