Literature DB >> 30452433

Systematic Review and Meta-Analysis of Diagnostic Accuracy of Endoscopic Ultrasound (EUS)-Guided Fine-Needle Aspiration (FNA) Using 22-gauge and 25-gauge Needles for Pancreatic Masses.

Guo Tian1,2, Haiwei Bao3, Ju Li3, Tian'an Jiang1,2.   

Abstract

BACKGROUND Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) has been used for detecting pancreatic cancer. We aimed to compare the diagnostic yield of both 22-gauge and 25-gauge EUS-FNA for the detection of pancreatic cancer. MATERIAL AND METHODS We searched the electronic databases including PubMed, EMBASE, Web of Science, Scopus, and Cochrane Library up to June 13, 2017. Two reviewers independently screened studies and extracted data. RESULTS We analyzed data from 1824 patients from 16 included studies. The estimated pooled data for the 22-gauge needles reported sensitivity was 0.89 (0.83-0.93), specificity was 1.00 (0.74-1.00), positive LR was 485.28 (2.55-92 000) and negative LR was 0.11 (0.07-0.17). Results for the 25-gauge needles showed the pooled sensitivity, specificity, positive and negative LR was 0.90 (0.86-0.93), 0.99 (0.89-1.00), 59.53 (7.99-443.66), and 0.10 (0.07-0.14), respectively. The 25-gauge needle had significantly higher pooled sensitivity than the 22-gauge needle (0.90 vs. 0.87, χ²=5.26, P=0.02) while there was no difference in the pooled specificity (0.96 vs. 0.98, χ²=2.12, P=0.15). The quality of most studies was assessed favorable using QUADAS-2 (quality assessment of diagnostic accuracy studies-2). CONCLUSIONS Our findings revealed that the 25-gauge EUS-FNA used for pancreatic lesions could have a higher diagnostic yield than using 22-gauge EUS-FNA. Nevertheless, well-designed prospective studies recruiting more patients are needed.

Entities:  

Mesh:

Year:  2018        PMID: 30452433      PMCID: PMC6257123          DOI: 10.12659/MSM.911405

Source DB:  PubMed          Journal:  Med Sci Monit        ISSN: 1234-1010


Background

Pancreatic cancer is the fourth fatal cause of cancer-related death in the world, and lacks definite diagnostic markers and causes poor prognosis, with a 5-year survival rate of only 1% to 4% [1]. Judging whether the pancreatic tumors are benign or malignant is crucial in choosing the optimal management. The ability to achieve the diagnosis of pancreatic cancer in asymptomatic patients can enable patients to have curative resection and better prognosis. Although many diagnostic imaging and biomarkers, like carbohydrate antigen 19-9 (CA19-9) and carcinoembryonic antigen (CEA), for this disease have been studied, most of these generated suboptimal results owing to their limited sensitivity, specificity, and positive predictive value [2,3]. In recent years, emerging minimally invasive tests for pancreatic cancer have been reported and endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is a promising diagnostic tool for pancreatic cancer. Numerous studies have suggested favorable accuracy of EUS-FNA for solid pancreatic lesions using the 22-gauge or the 25-gauge needle. The effectivity and accuracy of EUS-FNA are susceptible to some factors such as site, size, needle type, and operational experience. Needle selection for EUS-guided sampling can be complicated. Larger-bore needles might not always offer high-quality specimens [4]. Although 22-gauge needles could result in more samples, it could also add the risk of procedure-related complications like pancreatitis, hemorrhage, abdominal pain, perforation, and hypotension [5]. A previous study showed that the presence of bloody contamination and cellular debris in the 22-gauge needle made the pathological examinations difficult [6]. In EUS, the 25-gauge needle had less sampling but could more smoothly enter into the torqued trans-duodenal position for sampling pancreatic head or uncinate process lesions. To date, only a small number of studies have been published in recent years related to which needles provided the better diagnostic yield, and results have been inconsistent. We performed this meta-analysis to contrast the differences in diagnostic yield of EUS-guided 22-gauge FNA with a 25-gauge EUS-FNA in sampling the pancreatic lesions.

Material and Methods

Search strategy

We conducted this systematic review and meta-analysis according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines [7], and performed a systematic literature search from PubMed, EMBASE, Web of Science, Scopus, and Cochrane Library up to June 13, 2017 using the following words: 22-gauge, 25-gauge, EUS, endoscopic ultrasonography, FNA, pancreatic, cancer (Supplementary Text 1). We checked and found the potential published studies in additional literatures and previous meta-analyses [2,3]. All studies were searched with no language limitations. In cases where the necessary information was not available in articles, we also tried to email corresponding authors to obtain the required data.

Inclusion criteria

Studies fulfilling the following criteria were eligible for assessing diagnostic accuracy for pancreatic cancer: 1) reference standard for pancreatic cancer diagnosed by pathology on surgical specimen, or clinical follow-up (clinical and/or imaging studies) beyond 6 months indicating whether there was tumor progression or not; 2) access to the values of true positive (TP), false positive (FP), false negative (FN), and true negative (TN) of both 22-gauge and 25-gauge EUS-FNA.

Exclusion criteria

Studies were excluded if the following items were present: 1) review, guidelines and meeting abstracts; 2) study population overlapped with other studies; 3) non-human studies. Two reviewers independently checked and screened the studies from the literature. Disagreements existing were finally decided through a third reviewer.

Data extraction and quality assessment

Two individuals extracted data from the eligible articles using a predefined protocol, including author, type of study, country, race, number of patients, tumor size, site, age, gender, the reference standard category, length of follow-up, and complications. If potential diagnostic data were not available in a paper, an email was sent to the authors for these data. All studies in this meta-analysis underwent quality assessment using the quality assessment of diagnostic accuracy studies-2 (QUADAS-2). The tool comprised 4 key domains (patient selection, index test, reference standard, and flow of patients through the study) were each rated based on the risk of bias, and the first 3 domains were also appraised for concerns about applicability [8]. Any disagreements were resolved by discussion between authors.

Statistical analysis

For the existing or derived 2×2 contingency tables deriving from TP, FP, FN, and TN on the basis of consistency between biopsy result and surgical pathology or clinical radiologic result. In the eligible studies, we evaluated values of sensitivity and specificity and 95% confidence interval (CI). We evaluated the pooled sensitivity, specificity, positive and negative likelihood ratios (LR), the diagnostic odds ratio (DOR), and the receiver operating characteristic curve (AUC-ROC) of EUS-guided FNA for pancreatic cancer using a bivariate mixed-effects regression model. We estimated statistical heterogeneity via the I statistic [9]. Threshold effect was estimated through the Spearmen correlation coefficient. We used funnel plots and Egger’s test to detect a potential publication bias [10]. We ruled that P<0.05 was statistical significant as for 2-sided tests. All statistical analyses were processed with Stata 12.0.

Results

Characteristics of eligible studies in the final analysis

Of 4036 records screened for titles or abstracts, 4020 papers were excluded and finally we found 16 articles that fulfilled the inclusion criteria (Figure 1), which comprised 6 retrospective and 10 prospective studies [11-26]. The baseline characteristics of the included studies are displayed in Table 1. Seven of the 16 included studies were done in Asian countries, 6 in North American countries, and 3 in European countries. Of 1824 recruited patients, 1108 patients with pancreatic masses underwent biopsies using 22-gauge needles and 877 patients by 25-gauge needles. Regarding the results of the quality estimation according to QUADAS-2, most studies were considered as favorable quality, part of which had unclear blind methods and length of follow-up (Table 2).
Figure 1

Study selection.

Table 1

Patient characteristics of included studies.

AuthorType of studyCountryNumber of patients (22G/ 25G)Tumor size, mm (22G/25G)Site (22G/25G)Age (22G/ 25G)Gender (M/F) (22G/25G)Reference standardFollow-up, monthsCompli-cation
Imazu H et al. 2009Pro-spectiveJapan12/12NA8 head; 3 body; 1 tailNANASurgical pathologyNANo
Lee JH et al. 2009Pro-spectiveAmerica12/12NA7 head or uncinate process; 3 body; 2 peripancreatic regionNANASurgical pathology or clinical follow-up12.44No
Siddiqui UD et al. 2009Pro-spectiveAmerica64/6730.283 head70.435/29; 47/20Surgical pathology or clinical follow-upNANo
Sakamoto H et al. 2009Pro-spectiveJapan24/2432.86 head; 6 uncinate process; 12 body or tailNANASurgical pathology or clinical follow-up12NA
Yusuf TE et al. 2009Retro-spectiveAmerica540/302NA410 head; 100 body; 23 tail/NA65/69300/240; 172/130Surgical pathology or clinical follow-up6.5No
Siddiqui AA et al. 2010Retro-spectiveAmerica26/17NANA65.8±11.2NASurgical pathology or clinical follow-up6NA
Camellini L et al. 2011Retro-spectiveItaly43/4127±12/28±1131 head/uncinate process/33 head/uncinate process66/67NASurgical pathology or clinical follow-up6NA
Fabbri C et al. 2011Pro-spectiveItaly50/5029±0.734 head; 8 uncinate process; 8 body68.2±7.430/20Surgical pathology or clinical follow-up10.2 (6–27)NA
Uehara H et al. 2011Retro-spectiveJapan54/66NA56 head; 42 body; 22 tail63.3172/43Surgical pathology or clinical follow-upNA2 pancreatitis
Suzuki R et al. 2012Pro-spectiveJapan20/2027.6±21.1/27.6±12.215 body or tail/11 body or tail67.9±8.5/67.5±8.711/9; 13/7Surgical pathology or clinical follow-up6No
Lee JK et al. 2013Pro-spectiveKorea94/9433.2±1.5/37.7±1.931 head or uncinate process; 63 body or tail/53 head or uncinate process; 41 body or tail58.5±11.8/61.3±11.154/40; 52/42Surgical pathology or clinical follow-up121 pancreatitis; 2 bleeding/ 6 pancreatitis; 4 bleeding
Vilmann P et al. 2013Pro-spectiveDen-mark28/3130.9±14.46/28.4±12.1NA62±13.6/64±11.4NASurgical pathology or clinical follow-up6No
Berzosa M et al. 2015Retro-spectiveAmerica56/563333 head; 5 uncinate process; 15 body; 2 tail; 6 peripancreatic lymph nodes62±14.435/26Surgical pathology or clinical follow-up6NA
Yang MJ et al. 2015Retro-spectiveKorea38/3834.1±12.6/33.8±16.321 head or uncinate process; 17 body or tail/17 head or uncinate process; 21 body or tail61.8±11.4/63.0±12.617/21; 18/20Surgical pathology or clinical follow-up8No
Mavrogenis G et al. 2015Pro-spectiveAmerica19/1939NA69NASurgical pathology or clinical follow-up7No
Park SW et al. 2016Pro-spectiveKorea28/2835.3±17.124 head; 4 uncinate process; 18 body; 10 tail65.8±9.535/21Surgical pathology or clinical follow-up6No

NA – not available.

Table 2

Quality assessment of included studies using QUADAS-2.

AuthorRisk of biasApplicability concerns
Patient selectionIndex testReference standardFlow & timingPatient selectionIndex testReference standard
Imazu H et al., 2009LRLRLRURHRURLR
Lee JH et al., 2009LRLRLRLRLRLRLR
Siddiqui UD et al., 2009LRLRURLRLRLRLR
Sakamoto H et al., 2009LRLRLRLRLRLRLR
Yusuf TE et al., 2009LRLRURLRLRLRLR
Siddiqui AA et al., 2010LRLRURLRURLRLR
Camellini L et al., 2011LRLRLRLRHRLRLR
Fabbri C et al., 2011LRLRLRLRLRLRLR
Uehara H et al., 2011LRLRURLRLRLRLR
Suzuki R et al., 2012LRLRURLRLRLRLR
Lee JK et al., 2013LRLRURLRLRLRLR
Vilmann P et al., 2013LRLRLRLRLRLRLR
Berzosa M et al., 2015LRLRURLRLRLRLR
Yang MJ et al., 2015LRLRLRLRLRLRLR
Mavrogenis G et al., 2015LRLRLRLRLRLRLR
Park SW et al., 2016LRLRLRLRLRLRLR

LR – low risk; HR – high risk; UR – unclear risk.

Meta-analysis of accuracy of EUS-FNA for diagnosis of pancreatic cancers

Overall, the diagnostic accuracy of 22-gauge and 25-gauge needles was high. The pooled data for 22-gauge needles reported sensitivity of 0.89 (0.83–0.93), specificity of 1.00 (0.74–1.00), positive LR of 485.28 (2.55–92 000), and negative LR of 0.11 (0.07–0.17). And results for 25-gauge needles showed pooled sensitivity, specificity, positive LR, and negative LR of 0.90 (0.86–0.93), 0.99 (0.89–1.00), 59.53 (7.99–443.66), and 0.10 (0.07–0.14), respectively (Figure 2 and Supplementary Figure 1). We compared the diagnostic accuracy of these 2 types of needles, and found that the pooled sensitivity was significantly higher in the 25-gauge needle (0.90 vs. 0.87, χ2=5.26, P=0.02), and slightly non-significant in pooled specificity (0.96 vs. 0.98, χ2=2.12, P=0.15). The AUC of SROC plots was both 0.97 (0.95–0.98) in 22-gauge and 25-gauge EUS-FNA (Figure 3). Threshold effects were not significant in the 2 groups (25-gauge: r=0.033, P=0.905; 22-gauge: r=0.190, P=0.480).
Figure 2

Forest plots showing sensitivity (A1, A2) and specificity (B1, B2) of all studies diagnosing pancreatic cancers by 22-gauge and 25-gauge endoscopic ultrasound-guided fine-needle aspiration.

Figure 3

Summary SROC plot of studies diagnosing pancreatic cancers by 22-gauge (A) and 25-gauge (B) endoscopic ultrasound-guided fine-needle aspiration.

Sensitivity analysis and publication bias

Sensitivity analysis showed robust results and no difference after every study was ruled out. However, some significant evidence of publication bias was detectable across studies (25-gauge: t=−3.02, P=0.009; 22-gauge: t=−5.14, P<0.001).

Discussion

Pancreatic cancer is a devastating disease with a great burden on patients, for which a rapid and correct diagnosis is necessary. Earlier diagnosis might increase survival by estimated 30% to 40% [3]. We carefully reviewed the included studies to appraise the diagnostic accuracy of EUS-guided FNA for pancreatic cancer comparing the 22-gauge needle and the 25-gauge needle. Results from the meta-analysis showed that the 25-gauge needle had significantly higher pooled sensitivity than the 22-gauge needle (0.90 vs. 0.87, χ2=5.26, P=0.02) while there was not a significant difference in pooled specificity (0.96 vs. 0.98, χ2=2.12, P=0.15). The diagnostic accuracy across studies had a similar heterogeneity (22-gauge: sensitivities 0.59 to 1.00; specificities 0.50 to 1.00; 25-gauge: sensitivities 0.68 to 1.00; specificities 0.80 to 1.00), both of which might showed that the methods are favorable. The heterogeneity in individual studies might result from the difference of study quality, prevalence, distribution of lesions, tumor size, or sample size. Although the pooled assessment of sensitivity and negative LR were fine, we should make a cautious conclusion. DOR combined the negative and curvilinear correlations between sensitivities and specificities, and we noted heterogeneity from studies regarding the different thresholds [27]. Thus, DOR might provide evidence for finding and treating patients earlier. In addition, SROC curves for EUS-FNA in pancreatic cancers showed that the AUC values were approximately close to 1 (AUC=0.97), which represented a favorable method to diagnose this disease. Higher positive LR revealed greater chance predicting adverse results while lower negative LR showed greater probability of achieving better outcomes [28]. The 2 needles both indicated strong diagnostic accuracy for ruling in pancreatic cancers (positive LRs beyond 10), but had less value for ruling out pancreatic cancers (positive LRs around 0.1). In our results, some explanations should be considered for the higher accuracy of 25-gauge FNA needle in sampling pancreatic lesions. In these studies, most lesions were located in the head and uncinate process of the pancreas. Although the 22-gauge FNA needle could be useful for diagnosis with the pancreatic uncinate and head masses, its application in this scenario is limited. In this study, the selection bias might result in the underestimation of the true diagnostic performance for 22-gauge EUS-FNA. It has been reported that the 25-gauge needle had higher diagnostic accuracy for pancreatic tumors compared to that of the 22-gauge needle (91.7% vs. 75%) [11], and the 25-gauge EUS-FNA was also reported to be superior to 22-gauge EUS-FNA in technical success rate because of its flexibility with thinner caliber [29], especially for hard lesions needing extreme scope bending, and less complications. To explain the results appropriately, several limitations should be noted in future research. First, the main source of bias within studies was associated with reporting of the reference standard and patient selection. Many studies used 2 approaches (surgical pathology or clinical follow-up) to confirm pancreatic cancer, which could affect the diagnostic accuracy. Second, blinding to the reference standard was not explicitly stated in some studies, which might lead to a risk of bias for results interpretation in these studies. Third, the length of follow-up in the included studies was not long, and it this might increase the risk of false-negative cases. Fourth, existing publication bias might also lead the physician to overestimate the availability of both these needles. Despite the aforementioned limitations, we carefully conducted a systematic literature search using a predefined protocol, and tried to minimize the risk of publication bias by reading all potential studies from the citations in other literatures. The risk of bias was seriously evaluated using QUADAS-2. Data extracting was analyzed through a bivariate mixed-effects regression model.

Conclusions

The meta-analysis suggested that 22-gauge and 25-gauge EUS-FNA for diagnosing pancreatic lesions had favorable results with a low risk of complications, but 25-gauge EUS-FNA might have a higher sensitivity for pancreatic tumor detection with good sensitivity. However, future well-designed prospective studies are required to identify the feasibility of different EUS-FNA needles for pancreatic lesions and address knowledge gaps. Search strategy ‘endoscopic ultrasonography’ OR EUS OR ‘ultrasonic endoscope’ 22 AND 25 AND pancrea* neoplasm OR cancer OR tumor OR tumour OR carcinoma OR oncology OR oncologic #1 AND #2 AND #3 ‘endoscopic ultrasonography’[Mesh] ‘pancrea’ [Mesh] cancer’ [Mesh] #5 AND #6 AND #7 #4 OR #8 ‘EUS’: ab,ti ‘endoscopic ultrasonography’: ab,ti ‘ultrasonic endoscope’: ab,ti #1 OR #2 OR #3 ‘22’: ab,ti ‘25’: ab,ti ‘pancrea’: ab,ti #5 OR #6 OR #7 ‘neoplasm’: ab,ti cancer’: ab,ti tumor’: ab,ti tumour’: ab,ti carcinoma’: ab,ti ‘oncology’: ab,ti ‘oncologic’: ab,ti #9 OR #10 OR #11 OR #12 OR #13 OR #14 OR #15 #4 AND #8 AND #16 TITLE-ABS-KEY (‘EUS’) TITLE-ABS-KEY (‘endoscopic ultrasonography’) TITLE-ABS-KEY (‘ultrasonic endoscope’) #1 OR #2 OR #3 TITLE-ABS-KEY (‘22’) TITLE-ABS-KEY (‘25’) TITLE-ABS-KEY (‘pancrea’) #5 OR #6 OR #7 TITLE-ABS-KEY (‘neoplasm’) TITLE-ABS-KEY (‘cancer’) TITLE-ABS-KEY (‘tumor’) TITLE-ABS-KEY (‘tumour’) TITLE-ABS-KEY (‘carcinoma’) TITLE-ABS-KEY (‘oncology’) TITLE-ABS-KEY (‘oncologic’) #9 OR #10 OR #11 OR #12 OR #13 #OR #14 OR #15 #4 AND #8 AND #16 TS=(endoscopic ultrasonography) TS=(fine needle) TS=(pancreatic) TS=(cancer) #1 AND #2 AND #3 AND #4 TI=(EUS) TI=(endoscopic ultrasonography) TI=(ultrasonic endoscope) #6 OR #7 OR #8 TI=(22) TI=(25) TI=(pancrea*) #10 AND #11 AND #12 neoplasm cancer tumor tumour carcinoma oncology oncologic #14 OR #15 OR #16 OR #17 OR #18 OR #19 OR #20 #9 AND #13 AND #21 #5 OR #22 ‘endoscopic ultrasonography’ OR EUS OR ‘ultrasonic endoscope’ pancrea* neoplasm OR cancer OR tumor OR tumour OR carcinoma OR oncology OR oncologic #1 and #2 and #3 MeSH descriptor: [Endosonography] explode all trees MeSH descriptor: [Pancreatic Neoplasms] explode all trees #5 and #6 #4 OR #7 Fagan nomogram for pancreatic cancers using 22-gague (A) and 25-gauge (B) endoscopic ultrasound-guided fine-needle aspiration.
Supplementary Text 1.

Search strategy

Search strategy:
Pubmed

‘endoscopic ultrasonography’ OR EUS OR ‘ultrasonic endoscope’

22 AND 25 AND pancrea*

neoplasm OR cancer OR tumor OR tumour OR carcinoma OR oncology OR oncologic

#1 AND #2 AND #3

‘endoscopic ultrasonography’[Mesh]

‘pancrea’ [Mesh]

‘cancer’ [Mesh]

#5 AND #6 AND #7

#4 OR #8

Embase

‘EUS’: ab,ti

‘endoscopic ultrasonography’: ab,ti

‘ultrasonic endoscope’: ab,ti

#1 OR #2 OR #3

‘22’: ab,ti

‘25’: ab,ti

‘pancrea’: ab,ti

#5 OR #6 OR #7

‘neoplasm’: ab,ti

‘cancer’: ab,ti

‘tumor’: ab,ti

‘tumour’: ab,ti

‘carcinoma’: ab,ti

‘oncology’: ab,ti

‘oncologic’: ab,ti

#9 OR #10 OR #11 OR #12 OR #13 OR #14 OR #15

#4 AND #8 AND #16

Scoups

TITLE-ABS-KEY (‘EUS’)

TITLE-ABS-KEY (‘endoscopic ultrasonography’)

TITLE-ABS-KEY (‘ultrasonic endoscope’)

#1 OR #2 OR #3

TITLE-ABS-KEY (‘22’)

TITLE-ABS-KEY (‘25’)

TITLE-ABS-KEY (‘pancrea’)

#5 OR #6 OR #7

TITLE-ABS-KEY (‘neoplasm’)

TITLE-ABS-KEY (‘cancer’)

TITLE-ABS-KEY (‘tumor’)

TITLE-ABS-KEY (‘tumour’)

TITLE-ABS-KEY (‘carcinoma’)

TITLE-ABS-KEY (‘oncology’)

TITLE-ABS-KEY (‘oncologic’)

#9 OR #10 OR #11 OR #12 OR #13 #OR #14 OR #15

#4 AND #8 AND #16

Web of science

TS=(endoscopic ultrasonography)

TS=(fine needle)

TS=(pancreatic)

TS=(cancer)

#1 AND #2 AND #3 AND #4

TI=(EUS)

TI=(endoscopic ultrasonography)

TI=(ultrasonic endoscope)

#6 OR #7 OR #8

TI=(22)

TI=(25)

TI=(pancrea*)

#10 AND #11 AND #12

neoplasm

cancer

tumor

tumour

carcinoma

oncology

oncologic

#14 OR #15 OR #16 OR #17 OR #18 OR #19 OR #20

#9 AND #13 AND #21

#5 OR #22

Cochrane library

‘endoscopic ultrasonography’ OR EUS OR ‘ultrasonic endoscope’

pancrea*

neoplasm OR cancer OR tumor OR tumour OR carcinoma OR oncology OR oncologic

#1 and #2 and #3

MeSH descriptor: [Endosonography] explode all trees

MeSH descriptor: [Pancreatic Neoplasms] explode all trees

#5 and #6

#4 OR #7

  26 in total

1.  Users' guides to the surgical literature: how to use an article about a diagnostic test. Evidence-Based Surgery Working Group.

Authors:  S Archibald; M Bhandari; A Thoma
Journal:  Can J Surg       Date:  2001-02       Impact factor: 2.089

2.  Trim and fill: A simple funnel-plot-based method of testing and adjusting for publication bias in meta-analysis.

Authors:  S Duval; R Tweedie
Journal:  Biometrics       Date:  2000-06       Impact factor: 2.571

3.  Twenty-one-gauge needles provide more cellular samples than twenty-five-gauge needles in fine-needle aspiration biopsy of the thyroid but may not provide increased diagnostic accuracy.

Authors:  V Tangpricha; B J Chen; N C Swan; A T Sweeney; A de las Morenas; J D Safer
Journal:  Thyroid       Date:  2001-10       Impact factor: 6.568

4.  Quantifying heterogeneity in a meta-analysis.

Authors:  Julian P T Higgins; Simon G Thompson
Journal:  Stat Med       Date:  2002-06-15       Impact factor: 2.373

5.  Meta-analyses of diagnostic studies.

Authors:  Ton J Cleophas; Aeilko H Zwinderman
Journal:  Clin Chem Lab Med       Date:  2009       Impact factor: 3.694

6.  Blinded prospective comparison of the performance of 22-gauge and 25-gauge needles in endoscopic ultrasound-guided fine needle aspiration of the pancreas and peri-pancreatic lesions.

Authors:  Jeffrey H Lee; John Stewart; William A Ross; Sharmila Anandasabapathy; Lianchun Xiao; Gregg Staerkel
Journal:  Dig Dis Sci       Date:  2009-08-11       Impact factor: 3.199

Review 7.  The integrin-extracellular matrix axis in pancreatic cancer.

Authors:  John J Grzesiak; Jason C Ho; Abdool R Moossa; Michael Bouvet
Journal:  Pancreas       Date:  2007-11       Impact factor: 3.327

8.  EUS-guided FNA of solid pancreatic masses: a prospective, randomized trial comparing 22-gauge and 25-gauge needles.

Authors:  Uzma D Siddiqui; Federico Rossi; Lawrence S Rosenthal; Manmeet S Padda; Visvanathan Murali-Dharan; Harry R Aslanian
Journal:  Gastrointest Endosc       Date:  2009-07-28       Impact factor: 9.427

9.  Prospective comparative study of the EUS guided 25-gauge FNA needle with the 19-gauge Trucut needle and 22-gauge FNA needle in patients with solid pancreatic masses.

Authors:  Hiroki Sakamoto; Masayuki Kitano; Takamitsu Komaki; Kazu Noda; Takaaki Chikugo; Kensaku Dote; Yoshifumi Takeyama; Kunal Das; Kenji Yamao; Masatoshi Kudo
Journal:  J Gastroenterol Hepatol       Date:  2008-11-20       Impact factor: 4.029

10.  Retrospective analysis of the utility of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic masses, using a 22-gauge or 25-gauge needle system: a multicenter experience.

Authors:  T E Yusuf; S Ho; D A Pavey; H Michael; F G Gress
Journal:  Endoscopy       Date:  2009-05-05       Impact factor: 10.093

View more
  2 in total

Review 1.  Role of Endoscopic Ultrasonography and Endoscopic Retrograde Cholangiopancreatography in the Diagnosis of Pancreatic Cancer.

Authors:  Yasutaka Ishii; Masahiro Serikawa; Tomofumi Tsuboi; Ryota Kawamura; Ken Tsushima; Shinya Nakamura; Tetsuro Hirano; Ayami Fukiage; Takeshi Mori; Juri Ikemoto; Yusuke Kiyoshita; Sho Saeki; Yosuke Tamura; Sayaka Miyamoto; Kazuaki Chayama
Journal:  Diagnostics (Basel)       Date:  2021-02-04

2.  Comparative diagnostic accuracy of EUS needles in solid pancreatic masses: a network meta-analysis.

Authors:  Samuel Han; Furqan Bhullar; Omar Alaber; Ayesha Kamal; Puanani Hopson; Kavin Kanthasamy; Sarah Coughlin; Livia Archibugi; Nikhil Thiruvengadam; Christopher Moreau; David Jin; Pedram Paragomi; Francisco Valverde-López; Sajan Nagpal; Cemal Yazici; Georgios Papchristou; Peter J Lee; Venkata Akshintala
Journal:  Endosc Int Open       Date:  2021-05-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.