Literature DB >> 30451342

A randomized clinical trial comparing Nitrofurazone-coated and uncoated urinary catheters in kidney transplant recipients: Results from a pilot study.

Fernando Gatti Menezes1, Luci Corrêa2, Jose Osmar Medina-Pestana3, Wilson Ferreira Aguiar4, Luis Fernando Aranha Camargo2.   

Abstract

BACKGROUND: Urinary tract infections are frequent complications early after kidney transplantation, and the use of antimicrobial coated catheters in settings other than transplantation has shown promising results for infection prevention. The purpose of this study was to compare the efficacy of Nitrofurazone-coated silicone urinary catheters with non-impregnated silicone urinary catheters in reducing bacteriuria and urinary tract infections in kidney transplant recipients.
METHODS: This single-center study, randomized controlled trial at the Hospital do Rim, a tertiary referral center in kidney transplantation, located in São Paulo, Brazil. Subjects involved living donor kidney transplant recipients, and were randomized 1:1 ratio with a computer-generated system to a Nitrofurazone-coated silicone urinary catheter and non-impregnated silicone urinary catheter from March 2013 to December 2014. Patients with asymptomatic bacteriuria or urinary tract infection at baseline, deceased kidney transplant donors, patients with known hypersensitivity to nitrofurantoin, pregnancy, and those refusing to sign the informed consent form were excluded from the study.
RESULTS: Two hundred fourteen subjects were randomized and one hundred seventy-six completed the study. There were no differences in the rates of asymptomatic bacteriuria (12.5% in the Nitrofurazone group and 11.4% in the control group, P = 0.99) and urinary tract infection (8% and 6.8%, P = 0.99) and the incidence of side effects was more frequent in the Nitrofurazone-impregnated silicone urinary catheter group (46.6% and 26.1%, P = 0.007).
CONCLUSION: The study suggests that there is no beneficial effect of the employment of Nitrofurazone-coated urinary catheter. TRIAL REGISTRATION NUMBER: ISRCTN57888785.
© 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  bacteriuria; kidney transplantation; urinary catheters; urinary tract infection

Mesh:

Substances:

Year:  2018        PMID: 30451342     DOI: 10.1111/tid.13031

Source DB:  PubMed          Journal:  Transpl Infect Dis        ISSN: 1398-2273            Impact factor:   2.228


  2 in total

Review 1.  Catheter-Associated Urinary Tract Infections: Current Challenges and Future Prospects.

Authors:  Glenn T Werneburg
Journal:  Res Rep Urol       Date:  2022-04-04

Review 2.  Catheter-Associated Urinary Infections and Consequences of Using Coated versus Non-Coated Urethral Catheters-Outcomes of a Systematic Review and Meta-Analysis of Randomized Trials.

Authors:  Vineet Gauhar; Daniele Castellani; Jeremy Yuen-Chun Teoh; Carlotta Nedbal; Giuseppe Chiacchio; Andrew T Gabrielson; Flavio Lobo Heldwein; Marcelo Langer Wroclawski; Jean de la Rosette; Rodrigo Donalisio da Silva; Andrea Benedetto Galosi; Bhaskar Kumar Somani
Journal:  J Clin Med       Date:  2022-07-30       Impact factor: 4.964