Literature DB >> 30448326

Direct Anterior Approach Total Hip Arthroplasty Using a Morphometrically Optimized Femoral Stem, a Conventional Operating Table, Without Fluoroscopy.

Shaoqi Tian1, Karan Goswami2, Jorge Manrique3, Kier Blevins2, Ibrahim Azboy2, William J Hozack2.   

Abstract

BACKGROUND: Our experience with direct anterior approach total hip arthroplasty (THA) suggests that it can be performed successfully with a morphometrically optimized metaphyseal-diaphyseal engaging femoral stem (NOT a short stem), a regular operating room table (NOT a special custom table), and WITHOUT intraoperative fluoroscopy. We report our minimum 2-year results.
METHODS: A retrospective review of a single-surgeon series of primary direct anterior approach THAs was performed. All procedures were performed on a regular table, without fluoroscopy, using a cementless tapered femoral stem. Clinical, functional, and radiographic outcomes were evaluated at a minimum of 2 years.
RESULTS: In total, 1017 primary THAs were performed. The preoperative Harris Hip Score was 40.7 ± 5.1 and improved to 95.3 ± 4.2 at minimum 2-year follow-up. There were 3 dislocations (0.3%) and 15 revisions (1.5%): 7 for infection (0.7%), 4 for periprosthetic fractures (0.4%), 2 for instability (0.2%), 1 for loosening (0.1%), and 1 for pain (0.1%). Five patients (0.5%) required blood transfusion. One patient developed deep vein thrombosis and pulmonary embolism. No intraoperative fractures, perforation, or THA-related mortality occurred. Neutral stem alignment was confirmed in 98.3%. Mean cup inclination was 38.8° ± 5.1° and anteversion was 16.2° ± 3.5°. The mean leg-length discrepancy was corrected from 1.2 ± 0.2 cm preoperatively to 0.2 ± 0.1 cm postoperatively.
CONCLUSION: Using a morphometrically optimized metaphyseal-diaphyseal engaging tapered femoral stem instead of a short stem reduces component malposition and minimizes risk of loosening. Combining the use of this implant design and the technique and elements described in our cohort demonstrated to have excellent results at 2 years. The patients will need continued follow-up to demonstrate further durability of this device and technique compared to others performing direct anterior THA.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  cementless tapered femoral stem; direct anterior approach; operating table; outcomes; total hip arthroplasty

Mesh:

Year:  2018        PMID: 30448326     DOI: 10.1016/j.arth.2018.10.023

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  Varus malalignment of short femoral stem not associated with post-hip arthroplasty fracture.

Authors:  Scott T Nishioka; Samantha N Andrews; Kristin Mathews; Cass K Nakasone
Journal:  Arch Orthop Trauma Surg       Date:  2021-11-30       Impact factor: 2.928

2.  Outcomes of primary total hip arthroplasty using 3D image-based custom stems in unselected patients: a systematic review.

Authors:  A Nogier; I Tourabaly; S Ramos-Pascual; J H Müller; M Saffarini; C Courtin
Journal:  EFORT Open Rev       Date:  2021-12-10

3.  Comparison of two different stems for total hip arthroplasty.

Authors:  Pedram Yavari; Bahareh Baghchi; Mehdi Tavassoli; Pouya Moshkdar; Sepehr Eslami; Amirhossein Sadeghian; Ghasem Mohammadsharifi
Journal:  Int J Burns Trauma       Date:  2021-06-15

4.  Component placement accuracy of two digital intraoperative fluoroscopy supplementation systems in direct anterior total hip arthroplasty.

Authors:  Tyler Thorne; Scott Nishioka; Samantha Andrews; Kristin Mathews; Cass Nakasone
Journal:  Arch Orthop Trauma Surg       Date:  2021-06-23       Impact factor: 3.067

Review 5.  Subsidence of a metaphyseal-anchored press-fit stem after 4-year follow-up: an EBRA-FCA analysis.

Authors:  Dietmar Dammerer; Philipp Blum; David Putzer; Dietmar Krappinger; Michael C Liebensteiner; Michael Nogler; Martin Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2021-07-21       Impact factor: 2.928

6.  Direct anterior approach or posterior approach in total hip arthroplasty: A direct comparative study protocol.

Authors:  Lingchao Kong; Long Chen; Li Sun; Xiaobin Tian
Journal:  Medicine (Baltimore)       Date:  2020-10-16       Impact factor: 1.817

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.