Literature DB >> 30447557

Ultra-thin occlusal veneers bonded to enamel and made of ceramic or hybrid materials exhibit load-bearing capacities not different from conventional restorations.

Alexis Ioannidis1, Sven Mühlemann2, Mutlu Özcan2, Jürg Hüsler3, Christoph H F Hämmerle2, Goran I Benic2.   

Abstract

OBJECTIVES: The objective of this study was to test whether or not the load-bearing capacity of occlusal veneers bonded to enamel and made of ceramic or hybrid materials does differ from those of porcelain-fused-to-metal or lithium disilicate glass ceramic crowns.
MATERIAL AND METHODS: In 80 human molars occlusal enamel was removed without extending into the dentin in order to mimic substance defects caused by attrition. The restorations were digitally designed at a standardized thickness of either 0.5 mm or 1.0 mm. For each thickness, 4 test groups were formed each including a different restorative material: "0.5-ZIR": 0.5 mm thick zirconia (Vita YZ HT); "1.0-ZIR": 1.0 mm thick zirconia (Vita YZ HT); "0.5-LDC": 0.5 mm thick lithium disilicate ceramic (IPS e.max Press); "1.0-LDC": 1.0 mm thick lithium disilicate ceramic (IPS e.max Press); "0.5-HYC": 0.5 mm thick PICN (Vita Enamic); "1.0-HYC": 1.0 mm thick PICN (Vita Enamic); "0.5-COC": 0.5 mm thick tooth shaded resin composite (Lava Ultimate) and "1.0-COC": 1.0 mm thick tooth shaded resin composite (Lava ultimate). Each group consists of 10 specimens. Two additional groups of 10 specimens each were used as controls and exhibited conventional crown preparations. In one group the crowns were made of lithium-disilicate ceramic ("CLD": IPS e.max CAD) and the other group consisted of porcelain-fused to metal crowns ("PFM"). All restorations were cemented onto the prepared teeth following the manufacturer's instruction of the corresponding luting cement. Subsequently, they were thermo-mechanically aged and then loaded until fracture. Load-bearing capacities (Fmax) between the groups were compared applying the Kruskal-Wallis test (p < 0.05) and pairwise group comparisons using the Dunn's method.
RESULTS: Median values (and quartiles) for the load-bearing capacity amounted to (Fmax) 2'407 (1'670; 2'490) N for the CLD group and to 2'033 (1'869; 2'445) N for the PFM group. For the 0.5 mm thick restorations Fmax reached the highest median value in group 0.5-HYC 2'390 (1'355; 2'490) N, followed by 0.5-COC 2'200 (1'217; 2'492) N and 0.5-LDC 1'692 (1'324; 2'355) N. No results were obtained for group 0.5-ZIR due to the impracticability to fabricate ultra-thin specimens. The distribution of the values for the 1.0 mm thick restorations was 2'489 (2'426; 2'491) N for 1.0-COC, 2'299 (2'156; 2'490) N for 1.0-ZIR, 2'124 (1'245; 2'491) N for 1.0-HYC, and 1'537 (1'245; 1'783) N for 1.0-LDC. The differences of the medians between the test and the control groups did not reach statistical significance for the 0.5 mm thick specimens (KW: p = 0.6952 and p = 0.6986). Within the groups exhibiting 1.0 mm thickness, however, significant different medians were found: 1.0-LDC < 1.0-ZIR and 1.0-LDC < 1.0-COC (KW: p < 0.0209).
CONCLUSIONS: Regarding their maximum load-bearing capacity, minimally invasive occlusal veneers made of ceramic and hybrid materials can be applied to correct occlusal tooth wear and thus replace conventional crown restorations.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Ceramics; Computer-aided design; Computer-aided manufacturing; Dental porcelain; Fatigue; Hybrid material; Occlusal dental veneers; Resins

Mesh:

Substances:

Year:  2018        PMID: 30447557     DOI: 10.1016/j.jmbbm.2018.09.041

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  5 in total

Review 1.  The influence of zirconia veneer thickness on the degree of conversion of resin-matrix cements: an integrative review.

Authors:  Christie M Tafur-Zelada; Oscar Carvalho; Filipe S Silva; Bruno Henriques; Mutlu Özcan; Júlio C M Souza
Journal:  Clin Oral Investig       Date:  2021-03-30       Impact factor: 3.573

2.  Compressive strength evaluation of thin occlusal veneers from different CAD/CAM materials, before and after acidic saliva exposure.

Authors:  Codruța Ille; Elena-Alina Moacă; Daniel Pop; Luciana Goguță; Carmen Opriș; Ioana Ligia Pîrvulescu; Liane Avram; Andrei Faur; Anca Jivănescu
Journal:  Odontology       Date:  2022-09-12       Impact factor: 2.885

3.  Additive Manufacturing of Lithium Disilicate with the LCM Process for Classic and Non-Prep Veneers: Preliminary Technical and Clinical Case Experience.

Authors:  Alexey Unkovskiy; Florian Beuer; Dilan Seda Metin; Daniel Bomze; Jeremias Hey; Franziska Schmidt
Journal:  Materials (Basel)       Date:  2022-09-01       Impact factor: 3.748

4.  Fracture resistance of bonded ceramic overlay restorations prepared in various designs.

Authors:  Wilasinee Channarong; Nuttakarn Lohawiboonkij; Pitsinee Jaleyasuthumkul; Kittipong Ketpan; Nut Duangrattanaprathip; Kornchanok Wayakanon
Journal:  Sci Rep       Date:  2022-10-05       Impact factor: 4.996

5.  Clinical Significance of Combined Weight-Bearing and Non-Weight-Bearing Positions and MRI Examination in Evaluating Genu Varus.

Authors:  Shan Zhu; Zhi Wang; Feng He
Journal:  Orthop Surg       Date:  2020-10-04       Impact factor: 2.071

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.