Literature DB >> 30441026

Vascular Graft Pressure-Flow Monitoring Using 3D Printed MWCNT-PDMS Strain Sensors.

J A Steve Majerus, Hao Chong, David Ariando, Connor Swingle, Joseph Potkay, Kath Bogie, Christian A Zorman.   

Abstract

Real-time monitoring of arteriovenous graft blood flow would provide early warning of graft failure to permit interventions such as angioplasty or graft replacement to avoid catastrophic failure. We have developed a new type of flexible pulsation sensor (FPS) consisting of a 3D printed elastic cuff wrapped around a graft and thus not in contact with blood. The FPS uses multi-walled carbon nanotubes (MWCNTs) dispersed in polydimethylsiloxane (PDMS) as a piezoresistive sensor layer, which is embedded within structural thixotropic PDMS. These materials were specifically developed to enable sensor additive manufacturing via 3D Bio-plotting, and the resulting strain sensor is more compliant and has a wider maximum strain range than graft materials. Here, we analyze the strain transduction mechanics on a vascular graft and describe the memristive properties of MWCNT-PDMS composites, which may be mitigated using AC biasing. In vitro testing of the FPS on a vascular graft phantom showed a robust, linear sensor output to pulsatile flows (170-650 mL/min) and pressures (62-175 mmHg). The FPS showed an RMS error when measuring pressure and flow of 7.7 mmHg and 29.3 mL/min, with a mean measurement error of 6.5% (pressure) and 8.0% (flow).

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 30441026      PMCID: PMC6699158          DOI: 10.1109/EMBC.2018.8512997

Source DB:  PubMed          Journal:  Annu Int Conf IEEE Eng Med Biol Soc        ISSN: 2375-7477


  8 in total

Review 1.  Improving vascular grafts: the importance of mechanical and haemodynamic properties.

Authors:  S E Greenwald; C L Berry
Journal:  J Pathol       Date:  2000-02       Impact factor: 7.996

2.  An inductively powered implantable blood flow sensor microsystem for vascular grafts.

Authors:  Jia Hao Cheong; Simon Sheung Yan Ng; Xin Liu; Rui-Feng Xue; Huey Jen Lim; Pradeep Basappa Khannur; Kok Lim Chan; Andreas Astuti Lee; Kai Kang; Li Shiah Lim; Cairan He; Pushpapraj Singh; Woo-Tae Park; Minkyu Je
Journal:  IEEE Trans Biomed Eng       Date:  2012-06-06       Impact factor: 4.538

3.  Application of full field optical studies for pulsatile flow in a carotid artery phantom.

Authors:  M Nemati; G B Loozen; N van der Wekken; G van de Belt; H P Urbach; N Bhattacharya; S Kenjeres
Journal:  Biomed Opt Express       Date:  2015-09-21       Impact factor: 3.732

4.  Clinical practice guidelines for vascular access.

Authors: 
Journal:  Am J Kidney Dis       Date:  2006-07       Impact factor: 8.860

5.  Implantable blood flow measurement techniques for humans.

Authors:  Simon Locke; Timothy Gale; David Kilpatrick
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2005

6.  Vascular access surveillance: case study of a false paradigm.

Authors:  William D Paulson; Louise Moist; Charmaine E Lok
Journal:  Semin Dial       Date:  2013-01-17       Impact factor: 3.455

7.  Necessity for elastic properties in synthetic arterial grafts.

Authors:  E R Gozna; W F Mason; A E Marble; D A Winter; F G Dolan
Journal:  Can J Surg       Date:  1974-05       Impact factor: 2.089

8.  A comparison between PTFE and denatured homologous vein grafts for haemodialysis access: a prospective randomised multicentre trial. The SMASH Study Group. Study of Graft Materials in Access for Haemodialysis.

Authors:  P J Bosman; P J Blankestijn; Y van der Graaf; R J Heintjes; H A Koomans; B C Eikelboom
Journal:  Eur J Vasc Endovasc Surg       Date:  1998-08       Impact factor: 7.069

  8 in total
  2 in total

1.  Vascular Pressure-Flow Measurement Using CB-PDMS Flexible Strain Sensor.

Authors:  Hao Chong; Jiongcheng Lou; Kath M Bogie; Christian A Zorman; Steve J A Majerus
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2019-10-10       Impact factor: 3.833

2.  A smartphone-enabled wireless and batteryless implantable blood flow sensor for remote monitoring of prosthetic heart valve function.

Authors:  Bernhard Vennemann; Dominik Obrist; Thomas Rösgen
Journal:  PLoS One       Date:  2020-01-14       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.