Literature DB >> 30440706

Fully Disposable Wireless Patch Sensor for Continuous Remote Patient Monitoring.

Nandakumar Selvaraj, Gabriel Nallathambi, Rod Moghadam, Arshan Aga.   

Abstract

Continuous remote monitoring with convenient wireless sensors is attractive for early detection of patient deterioration, preventing adverse events and leading to better patient care. This article presents an innovative sensor design of VitalPatch, a fully disposable wireless biosensor, for remote continuous monitoring, and details the performance assessments from bench testing and laboratory validation in 57 subjects. The bench testing results reveal that VitalPatch's QRS detection had a positive predictive value of $> 99$% from testing with ECG databases. The accuracies of HR, BR and skin temp (in mean absolute error, MAE) from bench testing were $< 5$ bpm, $< 1$ brpm, $< 1 ^{ \circ}C$ respectively. The laboratory testing in 57 subjects revealed the accuracy of HR and BR to be $2.2 \pm 1.5$ bpm and $1.7 \pm 0.7$ brpm respectively for stationary periods. The absolute percent error in detecting steps was $4.7 \pm 4.6$%, and the accuracy in detecting posture was $96.4 \pm 3.1$%. Meanwhile, the specificity and sensitivity of fall detection $( \mathrm {n}=20)$ was found to be 100% and 93.8%, respectively. In conclusion, VitalPatch biosensor demonstrated clinically acceptable accuracies for its vital signs and actigraphy metrics applicable for continuous unobtrusive patient monitoring.

Entities:  

Mesh:

Year:  2018        PMID: 30440706     DOI: 10.1109/EMBC.2018.8512569

Source DB:  PubMed          Journal:  Annu Int Conf IEEE Eng Med Biol Soc        ISSN: 2375-7477


  6 in total

1.  Cardiac Ambulatory Monitoring: New Wireless Device Validated Against Conventional Holter Monitoring in a Case Series.

Authors:  Srinivasan Murali; Nicolas Brugger; Francisco Rincon; Manoj Mashru; Stéphane Cook; Jean-Jacques Goy
Journal:  Front Cardiovasc Med       Date:  2020-11-30

Review 2.  Remote Cardiac Rhythm Monitoring in the Era of Smart Wearables: Present Assets and Future Perspectives.

Authors:  Anastasia Xintarakou; Vasileios Sousonis; Dimitrios Asvestas; Panos E Vardas; Stylianos Tzeis
Journal:  Front Cardiovasc Med       Date:  2022-03-01

3.  ECG Signal Quality Assessments of a Small Bipolar Single-Lead Wearable Patch Sensor.

Authors:  Paurakh Lal Rajbhandary; Gabriel Nallathambi; Nandakumar Selvaraj; Thang Tran; Olivier Colliou
Journal:  Cardiovasc Eng Technol       Date:  2022-03-15       Impact factor: 2.495

Review 4.  Remote Monitoring of Chronic Critically Ill Patients after Hospital Discharge: A Systematic Review.

Authors:  Dmitriy Viderman; Elena Seri; Mina Aubakirova; Yerkin Abdildin; Rafael Badenes; Federico Bilotta
Journal:  J Clin Med       Date:  2022-02-15       Impact factor: 4.241

5.  Patient Acceptability of a Novel Technological Solution (Ambient Intelligent Geriatric Management System) to Prevent Falls in Geriatric and General Medicine Wards: A Mixed-Methods Study.

Authors:  Joanne Dollard; Keith D Hill; Anne Wilson; Damith C Ranasinghe; Kylie Lange; Katherine Jones; Eileen Mary Boyle; Mengqi Zhou; Nicholas Ng; Renuka Visvanathan
Journal:  Gerontology       Date:  2022-04-29       Impact factor: 5.597

6.  Current Evidence for Continuous Vital Signs Monitoring by Wearable Wireless Devices in Hospitalized Adults: Systematic Review.

Authors:  Jobbe P L Leenen; Crista Leerentveld; Joris D van Dijk; Henderik L van Westreenen; Lisette Schoonhoven; Gijsbert A Patijn
Journal:  J Med Internet Res       Date:  2020-06-17       Impact factor: 5.428

  6 in total