Literature DB >> 30440305

The Accuracy of Atrial Fibrillation Detection from Wrist Photoplethysmography. A Study on Post-Operative Patients.

Adrian Tarniceriu, Jarkko Harju, Zeinab Rezaei Yousefi, Antti Vehkaoja, Jakub Parak, Arvi Yli-Hankala, Ilkka Korhonen.   

Abstract

Atrial fibrillation (AF) is the most common type of cardiac arrhythmia. Although not life-threatening itself, AF significantly increases the risk of stroke and myocardial infarction. Current tools available for screening and monitoring of AF are inadequate and an unobtrusive alternative, suitable for long-term use, is needed. This paper evaluates an atrial fibrillation detection algorithm based on wrist photoplethysmographic (PPG) signals. 29 patients recovering from surgery in the post-anesthesia care unit were monitored. 15 patients had sinus rhythm (SR, 67.5± 10.7 years old, 7 female) and 14 patients had AF (74.8± 8.3 years old, 8 female) during the recordings. Inter-beat intervals (IBI) were estimated from PPG signals. As IBI estimation is highly sensitive to motion or other types of noise, acceleration signals and PPG waveforms were used to automatically detect and discard unreliable IBI. AF was detected from windows of 20 consecutive IBI with 98.45±6.89% sensitivity and 99.13±1.79% specificity for 76.34±19.54% of the time. For the remaining time, no decision was taken due to the lack of reliable IBI. The results show that wrist PPG is suitable for long term monitoring and AF screening. In addition, this technique provides a more comfortable alternative to ECG devices.

Entities:  

Mesh:

Year:  2018        PMID: 30440305     DOI: 10.1109/EMBC.2018.8513197

Source DB:  PubMed          Journal:  Annu Int Conf IEEE Eng Med Biol Soc        ISSN: 2375-7477


  4 in total

1.  Visual Reassessment with Flux-Interval Plot Configuration after Automatic Classification for Accurate Atrial Fibrillation Detection by Photoplethysmography.

Authors:  Justin Chu; Wen-Tse Yang; Yao-Ting Chang; Fu-Liang Yang
Journal:  Diagnostics (Basel)       Date:  2022-05-24

Review 2.  Photoplethysmography based atrial fibrillation detection: a review.

Authors:  Tania Pereira; Nate Tran; Kais Gadhoumi; Michele M Pelter; Duc H Do; Randall J Lee; Rene Colorado; Karl Meisel; Xiao Hu
Journal:  NPJ Digit Med       Date:  2020-01-10

3.  Wearable technology to inform the prediction and diagnosis of cardiorespiratory events: a scoping review.

Authors:  Hamzeh Khundaqji; Wayne Hing; James Furness; Mike Climstein
Journal:  PeerJ       Date:  2021-12-22       Impact factor: 2.984

4.  Premature Atrial and Ventricular Contraction Detection using Photoplethysmographic Data from a Smartwatch.

Authors:  Dong Han; Syed Khairul Bashar; Fahimeh Mohagheghian; Eric Ding; Cody Whitcomb; David D McManus; Ki H Chon
Journal:  Sensors (Basel)       Date:  2020-10-05       Impact factor: 3.847

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.