Management of diabetics with the use of a microprocessor: comparison of insulin treatments based on blood and urine glucose levels.

I Hermányi1, G Tamás.   

Abstract

The insulin treatment of 8 insulin-dependent diabetics was controlled with a microprocessor (Better Control Medical Computer, BCMC, Inc., Toronto, Canada) with information derived from blood or first voided urine glucose concentrations assessed by reagent strips four times a day, before the three main meals and bedtime snack. The microprocessor recommends modification of the insulin doses so as to reach a pre-prandial blood glucose value of 110 mg/dl or a urine glucose concentration of 0.1 g/dl. During the first two weeks self-management was uniformly applied by the patients, based on their blood glucose concentration. Subsequently, it was continued by the patients who were divided into two groups, one using the blood, the other the urine glucose concentrations, each for three weeks, alternately. During microprocessor treatment the patients' mean blood glucose profiles decreased from 152 +/- 37 mg/dl to 126 +/- 28 mg/dl. No difference was found between treatments based on blood or urine glucose concentrations concerning either the mean blood glucose profiles or the number of hypoglycemic episodes in the presence of an average glucose threshold and good renal function. The first voided urine glucose concentration and mean and maximal blood glucose values obtained at the time of urine filtration were closely correlated (r = 0.82 and 0.86, p less than 0.001).

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3043988     DOI: 10.1007/BF02581243

Source DB:  PubMed          Journal:  Acta Diabetol Lat        ISSN: 0001-5563


  24 in total

1.  Performance of blood-glucose analysers.

Authors:  E F Legg; H G Sammons
Journal:  Lancet       Date:  1979-06-02       Impact factor: 79.321

2.  Validity of urine glucose measurements for estimating plasma glucose concentration.

Authors:  J T Hayford; J A Weydert; R G Thompson
Journal:  Diabetes Care       Date:  1983 Jan-Feb       Impact factor: 19.112

3.  Self-monitoring of blood glucose. American Diabetes Association.

Authors: 
Journal:  Diabetes Care       Date:  1985 Sep-Oct       Impact factor: 19.112

4.  The influence of renal threshold on the interpretation of urine tests for glucose in diabetic patients.

Authors:  S Walford; M M Page; S P Allison
Journal:  Diabetes Care       Date:  1980 Nov-Dec       Impact factor: 19.112

5.  Variations in renal threshold for glucose in Type 1 (insulin-dependent) diabetes mellitus.

Authors:  K Johansen; P A Svendsen; B Lørup
Journal:  Diabetologia       Date:  1984-03       Impact factor: 10.122

6.  A critical evaluation of methods of monitoring diabetic control.

Authors:  R Tattersall; S Walford; I Peacock; E Gale; S Allison
Journal:  Diabetes Care       Date:  1980 Jan-Feb       Impact factor: 19.112

7.  Patient self-monitoring of blood glucose and refinements of conventional insulin treatment.

Authors:  R Tattersall; E Gale
Journal:  Am J Med       Date:  1981-01       Impact factor: 4.965

8.  Relationship between urinary and blood glucose in diabetic children.

Authors:  N K Griffin; M A Smith; P A Jenkins; G Werther; J D Baum
Journal:  Arch Dis Child       Date:  1979-05       Impact factor: 3.791

9.  Correlation between plasma and urine glucose in diabetes.

Authors:  L R Morris; J A McGee; A E Kitabchi
Journal:  Ann Intern Med       Date:  1981-04       Impact factor: 25.391

10.  Management of the pregnant diabetic: home or hospital, with or without glucose meters?

Authors:  S M Stubbs; J M Brudenell; D A Pyke; P J Watkins; W A Stubbs; K G Alberti
Journal:  Lancet       Date:  1980-05-24       Impact factor: 79.321

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.