Literature DB >> 30439624

Electrochemical immunosensor for CDH22 biomarker based on benzaldehyde substituted poly(phosphazene) modified disposable ITO electrode: A new fabrication strategy for biosensors.

Muhammet Aydın1, Elif Burcu Aydın2, Mustafa Kemal Sezgintürk3.   

Abstract

A novel label-free impedimetric immunosensor was fabricated for rapid, selective and sensitive detection and quantification of Cadherin-like protein 22 (CDH22), a cancer marker, in human serum by using easy and quickly prepared disposable ITO immunoelectrode. cancer marker, in human serum by using easy and quickly prepared disposable ITO immunoelectrode. The biosensing approach implied the use of ITO electrode coated with poly(phosphazene) polymer including benzaldehyde groups attached with CDH22 antibody and CDH22 antigens. Benzaldehyde side groups containing poly(phosphazene) film coated disposable ITO electrode were utilized as an immunosensing platform and anti-CDH22 antibodies bound to aldehyde groups of benzaldehyde substituted poly(phosphazene) (P-PHP) covalently. The immunosensor modification steps and affinity interaction between anti-CDH22 antibodies and CDH22 antigens were observed by EIS and CV in the presence of the redox couple. Furthermore, antibody immobilization was followed via FTIR and Raman spectroscopy. The morphological analyses of the suggested immunosensor during the fabrication steps were carried out with SEM and AFM monitoring. All the experimental parameters affecting the construction of the immunoelectrodes were optimized. The fabricated immunosensor exhibited an excellent working performance with a wide detection linear range (0.015-2.9 pg/mL) and low limit of detection (4.4 fg/mL). Moreover, the proposed immunosensor had great reproducibility, repeatability and long-term stability. Additionally, the fabricated immunosensor was successfully used in the quantification of CDH22 in human serum without any pretreatment.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Benzaldehyde substituted poly(phosphazene); Cadherin-like protein 22; Cancer biomarker; Electrochemical impedance spectroscopy

Mesh:

Substances:

Year:  2018        PMID: 30439624     DOI: 10.1016/j.bios.2018.10.051

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Simple, fast and environmentally friendly method to determine ciprofloxacin in wastewater samples based on an impedimetric immunosensor.

Authors:  Rafaela Silva Lamarca; Ricardo Adriano Dorledo de Faria; Maria Valnice Boldrin Zanoni; Marcelo Nalin; Paulo Clairmont Feitosa de Lima Gomes; Younès Messaddeq
Journal:  RSC Adv       Date:  2020-01-08       Impact factor: 4.036

2.  Development of a biosensor platform based on ITO sheets modified with 3-glycidoxypropyltrimethoxysilane for early detection of TRAP1.

Authors:  Berfin Vural; Meltem ÇaliŞkan; Mustafa Kemal SezgİntÜrk
Journal:  Turk J Chem       Date:  2020-04-01       Impact factor: 1.239

3.  Highly selective and sensitive sandwich immunosensor platform modified with MUA-capped GNPs for detection of spike Receptor Binding Domain protein: a precious marker of COVID 19 infection.

Authors:  Elif Burcu Aydın; Muhammet Aydın; Mustafa Kemal Sezgintürk
Journal:  Sens Actuators B Chem       Date:  2021-06-24       Impact factor: 7.460

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.