The right blood collection tube for therapeutic drug monitoring and toxicology screening procedures: Standard tubes, gel or mechanical separator?

Aurélien Schrapp1, Céline Mory2, Thomas Duflot3, Tony Pereira2, Laurent Imbert2, Fabien Lamoureux4.   

Abstract

Stability data of toxics or drugs in gel-based or mechanical separation blood collection tubes are lacking, especially for therapeutic drug monitoring and clinical toxicology procedures. According to ISO 15189 accreditation standard, laboratories need to master the entire preanalytical process including the stability of analytes in a specific tube. Here we explored the impact of BD PST™ II and Barricor™ separator tubes on the stability of 167 therapeutic compounds and common drugs of abuse in plasma samples using LC-MS/MS. Forty drugs were significantly affected by the use of PST™ II tubes, including antidepressants (11/26), neuroleptics (9/13), cardiovascular drugs (5/26), anxiolytics and hypnotics (4/25) and some drugs of abuse (5/26). Six compounds exhibited significant reduction by the mechanical Barricor™ tubes. Ten drugs exhibited low (<85%) but non-significant recoveries due to inter-assay variability. Besides, a logP > 3.3 was determined as a cut-off value to predict a potential lack of stability in PST™ II gel tubes with an 86.4% sensitivity and a 61.4% specificity. As a consequence, determination of drugs with a logP > 3.3 should be carried out with caution in plasma samples withdrawn on PST™ II. The study showed the Barricor™ and non-gel tubes cause less drug interference and are recommended for the drugs studied.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Blood collection tubes; Drug stability; LC-MS/MS; Plasma sampling; Separator gel; Therapeutic drug monitoring; Toxicology

Mesh:

Substances:

Year:  2018        PMID: 30439354     DOI: 10.1016/j.cca.2018.10.043

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  3 in total

1.  Comparison of Three Blood Collection Tubes for 35 Biochemical Analytes: The Becton Dickinson Barricor Tube, Serum Separating Tube, and Plasma Separating Tube.

Authors:  Sunghwan Shin; Jongwon Oh; Hyung-Doo Park
Journal:  Ann Lab Med       Date:  2020-08-25       Impact factor: 3.464

Review 2.  Paroxetine-Overview of the Molecular Mechanisms of Action.

Authors:  Magdalena Kowalska; Jacek Nowaczyk; Łukasz Fijałkowski; Alicja Nowaczyk
Journal:  Int J Mol Sci       Date:  2021-02-07       Impact factor: 5.923

3.  Switching from serum to plasma: Implementation of BD Vacutainer® Barricor™ Plasma Blood Collection Tubes improves sample quality and laboratory turnaround time.

Authors:  Christian Ramakers; Brendan Meyer; Wanfei Yang; Elizabeth Plokhoy; Yan Xiong; Stephen Church; Nitin Kaushik
Journal:  Pract Lab Med       Date:  2019-12-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.